gsd-2023-49131
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-49131",
    "id": "GSD-2023-49131"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-49131"
      ],
      "details": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
      "id": "GSD-2023-49131",
      "modified": "2023-12-13T01:20:35.364411Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2023-49131",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Solid Edge SE2023",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V223.0 Update 10"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-824",
                "lang": "eng",
                "value": "CWE-824: Access of Uninitialized Pointer"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6708C521-2523-4FFE-8D66-01386DF0FAAF",
                    "versionEndExcluding": "223.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*",
                    "matchCriteriaId": "E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*",
                    "matchCriteriaId": "619B13A0-ADF3-4CC9-A5BD-6C99AE369D43",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*",
                    "matchCriteriaId": "E4C4B3EA-853A-4C75-AA5F-319E2802A722",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*",
                    "matchCriteriaId": "28C04B66-7E6F-49E6-B7A9-E7357ADE5936",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*",
                    "matchCriteriaId": "99A72C67-00A3-499A-9DDC-73AD29672A08",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*",
                    "matchCriteriaId": "9C7B34D6-925F-4DB9-8418-962F35FE11C6",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*",
                    "matchCriteriaId": "211C7830-D4B9-4315-BDE8-F108FF6A609C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*",
                    "matchCriteriaId": "52647713-2F45-4D35-B31A-5BB2E15175EF",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*",
                    "matchCriteriaId": "4378378B-BAEA-4200-9336-936835322DF6",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*",
                    "matchCriteriaId": "57968030-2B5F-41C1-B8B4-2405C84E3A06",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones "
          }
        ],
        "id": "CVE-2023-49131",
        "lastModified": "2024-01-10T20:30:29.007",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-01-09T10:15:19.310",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-824"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.