gsd-2024-0802
Vulnerability from gsd
Modified
2024-01-23 06:02
Details
Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-0802" ], "details": "Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet.", "id": "GSD-2024-0802", "modified": "2024-01-23T06:02:20.705523Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2024-0802", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC-Q Series Q03UDECPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q04UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q06UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q10UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q13UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q20UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q26UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q50UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q100UDEHCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q03UDVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q04UDVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q06UDVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q13UDVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q26UDVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q04UDPVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q06UDPVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q13UDPVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-Q Series Q26UDPVCPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L02CPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L06CPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L26CPU", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L02CPU-P", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L06CPU-P", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L26CPU-P", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L26CPU-BT", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } }, { "product_name": "MELSEC-L Series L26CPU-PBT", "version": { "version_data": [ { "version_affected": "=", "version_value": "all versions" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-468", "lang": "eng", "value": "CWE-468 Incorrect Pointer Scaling" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU99690199/", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU99690199/" }, { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-14", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-14" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "Incorrect Pointer Scaling vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series and MELSEC-L Series CPU modules allows a remote unauthenticated attacker to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet." }, { "lang": "es", "value": "Vulnerabilidad de escalado de puntero incorrecto en los m\u00f3dulos de CPU de las series MELSEC-Q y MELSEC-L de Mitsubishi Electric Corporation permite a un atacante remoto no autenticado leer informaci\u00f3n arbitraria de un producto objetivo o ejecutar c\u00f3digo malicioso en un producto objetivo enviando un paquete especialmente manipulado." } ], "id": "CVE-2024-0802", "lastModified": "2024-03-15T12:53:06.423", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Secondary" } ] }, "published": "2024-03-15T01:15:57.703", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://jvn.jp/vu/JVNVU99690199/" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-14" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-468" } ], "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "type": "Primary" } ] } } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.