gsd-2024-1212
Vulnerability from gsd
Modified
2024-02-03 06:02
Details
Unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-1212" ], "details": "Unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution.\n\n\n", "id": "GSD-2024-1212", "modified": "2024-02-03T06:02:22.360511Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security@progress.com", "ID": "CVE-2024-1212", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "LoadMaster", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "lessThan": "7.2.48.10", "status": "affected", "version": "7.2.48.1", "versionType": "semver" }, { "lessThan": "7.2.54.8", "status": "affected", "version": "7.2.54.0", "versionType": "semver" }, { "lessThan": "7.2.59.2", "status": "affected", "version": "7.2.55.0", "versionType": "semver" } ] } } ] } } ] }, "vendor_name": "Progress Software" } ] } }, "credits": [ { "lang": "en", "value": "Rhino Security Labs" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution.\n\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-78", "lang": "eng", "value": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://kemptechnologies.com/", "refsource": "MISC", "url": "https://kemptechnologies.com/" }, { "name": "https://freeloadbalancer.com/", "refsource": "MISC", "url": "https://freeloadbalancer.com/" }, { "name": "https://support.kemptechnologies.com/hc/en-us/articles/24325072850573-Release-Notice-LMOS-7-2-59-2-7-2-54-8-7-2-48-10-CVE-2024-1212", "refsource": "MISC", "url": "https://support.kemptechnologies.com/hc/en-us/articles/24325072850573-Release-Notice-LMOS-7-2-59-2-7-2-54-8-7-2-48-10-CVE-2024-1212" }, { "name": "https://support.kemptechnologies.com/hc/en-us/articles/23878931058445-LoadMaster-Security-Vulnerability-CVE-2024-1212", "refsource": "MISC", "url": "https://support.kemptechnologies.com/hc/en-us/articles/23878931058445-LoadMaster-Security-Vulnerability-CVE-2024-1212" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "Unauthenticated remote attackers can access the system through the LoadMaster management interface, enabling arbitrary system command execution.\n\n\n" }, { "lang": "es", "value": "Los atacantes remotos no autenticados pueden acceder al sistema a trav\u00e9s de la interfaz de administraci\u00f3n de LoadMaster, lo que permite la ejecuci\u00f3n arbitraria de comandos del sistema." } ], "id": "CVE-2024-1212", "lastModified": "2024-02-22T19:07:27.197", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "security@progress.com", "type": "Secondary" } ] }, "published": "2024-02-21T18:15:50.417", "references": [ { "source": "security@progress.com", "url": "https://freeloadbalancer.com/" }, { "source": "security@progress.com", "url": "https://kemptechnologies.com/" }, { "source": "security@progress.com", "url": "https://support.kemptechnologies.com/hc/en-us/articles/23878931058445-LoadMaster-Security-Vulnerability-CVE-2024-1212" }, { "source": "security@progress.com", "url": "https://support.kemptechnologies.com/hc/en-us/articles/24325072850573-Release-Notice-LMOS-7-2-59-2-7-2-54-8-7-2-48-10-CVE-2024-1212" } ], "sourceIdentifier": "security@progress.com", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "security@progress.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.