gsd-2024-23795
Vulnerability from gsd
Modified
2024-01-23 06:02
Details
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-23795" ], "details": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0012), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.", "id": "GSD-2024-23795", "modified": "2024-01-23T06:02:22.243825Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2024-23795", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Tecnomatix Plant Simulation V2201", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V2201.0012" } ] } }, { "product_name": "Tecnomatix Plant Simulation V2302", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V2302.0006" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0012), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process." } ] }, "impact": { "cvss": [ { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-787", "lang": "eng", "value": "CWE-787: Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "matchCriteriaId": "92315B86-671A-48F9-9D7D-C638DABD8520", "versionEndExcluding": "2201.0012", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "matchCriteriaId": "D222D65A-C271-4BE4-8139-DB5F38D053D5", "versionEndExcluding": "2302.0006", "versionStartIncluding": "2302.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0012), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones \u0026lt; V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones \u0026lt; V2302.0006). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza un archivo WRL especialmente manipulado. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual." } ], "id": "CVE-2024-23795", "lastModified": "2024-02-13T19:21:23.593", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2024-02-13T09:15:47.550", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.