gsd-2024-28045
Vulnerability from gsd
Modified
2024-04-02 05:02
Details
Improper neutralization of input within the affected product could lead to cross-site scripting.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-28045" ], "details": "\nImproper neutralization of input within the affected product could lead to cross-site scripting.\n\n", "id": "GSD-2024-28045", "modified": "2024-04-02T05:02:55.579018Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2024-28045", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DIAEnergie", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "v1.10.00.005" } ] } } ] }, "vendor_name": "Delta Electronics" } ] } }, "credits": [ { "lang": "en", "value": "Michael Heinzl reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nImproper neutralization of input within the affected product could lead to cross-site scripting.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-79", "lang": "eng", "value": "CWE-79: Improper neutralization of input during web page generation (\u0027Cross-site scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n" } ], "source": { "advisory": "ICSA-24-074-12", "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "\nImproper neutralization of input within the affected product could lead to cross-site scripting.\n\n" }, { "lang": "es", "value": "Una neutralizaci\u00f3n inadecuada de la entrada dentro del producto afectado podr\u00eda dar lugar a cross-site scripting." } ], "id": "CVE-2024-28045", "lastModified": "2024-03-22T12:45:36.130", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 2.5, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2024-03-21T23:15:10.467", "references": [ { "source": "ics-cert@hq.dhs.gov", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.