GSD-2024-29961

Vulnerability from gsd - Updated: 2024-04-03 05:02
Details
A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.
Aliases

{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-29961"
      ],
      "details": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\n",
      "id": "GSD-2024-29961",
      "modified": "2024-04-03T05:02:30.737345Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "sirt@brocade.com",
        "ID": "CVE-2024-29961",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Brocade SANnav",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "affected",
                            "versions": [
                              {
                                "status": "affected",
                                "version": "before v2.3.1 and v2.3.0a"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Brocade"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-200",
                "lang": "eng",
                "value": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246",
            "refsource": "MISC",
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability affects Brocade SANnav before v2.3.1 and v2.3.0a. It allows a Brocade SANnav service to send ping commands in the background at regular intervals to gridgain.com to check if updates are available for the Component. This could make an unauthenticated, remote attacker aware of the behavior and launch a supply-chain attack against a Brocade SANnav appliance.\n"
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad afecta a Brocade SANnav anterior a v2.3.1 y v2.3.0a. Permite que un servicio Brocade SANnav env\u00ede comandos de ping en segundo plano a intervalos regulares a gridgain.com para verificar si hay actualizaciones disponibles para el Componente. Esto podr\u00eda hacer que un atacante remoto no autenticado se d\u00e9 cuenta del comportamiento y lance un ataque a la cadena de suministro contra un dispositivo Brocade SANnav."
          }
        ],
        "id": "CVE-2024-29961",
        "lastModified": "2024-04-19T13:10:25.637",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 4.2,
              "source": "sirt@brocade.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-04-19T04:15:10.553",
        "references": [
          {
            "source": "sirt@brocade.com",
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23246"
          }
        ],
        "sourceIdentifier": "sirt@brocade.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-200"
              }
            ],
            "source": "sirt@brocade.com",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.