icsa-17-061-03
Vulnerability from csaf_cisa
Published
2017-03-02 00:00
Modified
2017-03-02 00:00
Summary
Siemens SINUMERIK Integrate and SINUMERIK Operate
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
ATTENTION: Remotely exploitable.
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.
Recommended Practices
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target this vulnerability. High skill level is needed to exploit.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. High skill level is needed to exploit.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-061-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-061-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-061-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-061-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-061-03" } ], "title": "Siemens SINUMERIK Integrate and SINUMERIK Operate", "tracking": { "current_release_date": "2017-03-02T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-061-03", "initial_release_date": "2017-03-02T00:00:00.000000Z", "revision_history": [ { "date": "2017-03-02T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-061-03 Siemens SINUMERIK Integrate and SINUMERIK Operate" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "2.0.3.00.016 (including) and 2.0.6 (excluding)", "product": { "name": "SINUMERIK Integrate Operate Client: All versions between 2.0.3.00.016 (including) and 2.0.6 (excluding)", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SINUMERIK Integrate Operate Client" }, { "branches": [ { "category": "product_version", "name": "4.5 | SP6 (including) and V4.5 SP6 Hotfix 8 (excluding)", "product": { "name": "Affected SINUMERIK Integrate Operate clients are included in the following Operate releases: All versions between V4.5 SP6 (including) and V4.5 SP6 Hotfix 8 (excluding)", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SINUMERIK Integrate Operate client" }, { "branches": [ { "category": "product_version", "name": "4.7 | SP2 Hotfix 1 (including) and V4.7 SP4 (excluding)", "product": { "name": "Affected SINUMERIK Integrate Operate clients are included in the following Operate releases: All versions between V4.7 SP2 Hotfix 1 (including) and V4.7 SP4 (excluding)", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SINUMERIK Integrate Operate client" }, { "branches": [ { "category": "product_version", "name": "vers:all/*", "product": { "name": "SINUMERIK Integrate Access MyMachine/Ethernet with AMM Service Engineer Client (ActiveX): All versions", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SINUMERIK Integrate Access MyMachine/Ethernet with AMM Service Engineer Client (ActiveX)" }, { "branches": [ { "category": "product_version", "name": "3.0.4.00.032 (including) and 3.0.6 (excluding)", "product": { "name": "SINUMERIK Integrate Operate Client: All versions between 3.0.4.00.032 (including) and 3.0.6 (excluding)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SINUMERIK Integrate Operate Client" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-2685", "cwe": { "id": "CWE-300", "name": "Channel Accessible by Non-Endpoint" }, "notes": [ { "category": "summary", "text": "A channel accessible by non-endpoint (-man-in-the-middle \u0027) vulnerability has been identified. This could allow an unverified attacker to eavesdrop, capture, or modify communications.CVE-2017-2685 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-2685" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens provides the following updates for affected SINUMERIK Integrate and SINUMERIK Operate versions:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "These updates can be obtained from a local Siemens service organization. If assistance is needed in identifying a local Siemens service organization, users may contact a local Siemens hotline at the following link:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "https://w3.siemens.com/aspa_app/", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://w3.siemens.com/aspa_app/" }, { "category": "vendor_fix", "details": "As a general security measure Siemens strongly recommends users configure their environment according to Siemens operational guidelines found below:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "https://www.industry.siemens.com/topics/global/en/industrial-security/Documents/operational_guidelines_industrial_security_en.pdf", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "https://www.industry.siemens.com/topics/global/en/industrial-security/Documents/operational_guidelines_industrial_security_en.pdf" }, { "category": "vendor_fix", "details": "For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-934525 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/en/cert-security-advisories.htm", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ], "url": "http://www.siemens.com/cert/en/cert-security-advisories.htm" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] } ] } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.