icsa-19-192-05
Vulnerability from csaf_cisa
Published
2019-07-11 00:00
Modified
2019-07-11 00:00
Summary
AVEVA Vijeo Citect and Citect SCADA Floating License Manager
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
These vulnerabilities could allow an attacker to deny the acquisition of a valid license for legal use of the product.
Critical infrastructure sectors
Energy
Countries/areas deployed
Worldwide
Company headquarters location
France
Recommended Practices
NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "organization": "Schneider Electric", "summary": "reporting these vulnerabilities to NCCIC" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "These vulnerabilities could allow an attacker to deny the acquisition of a valid license for legal use of the product.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-19-192-05 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-192-05.json" }, { "category": "self", "summary": "ICS Advisory ICSA-19-192-05 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-192-05" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "AVEVA Vijeo Citect and Citect SCADA Floating License Manager", "tracking": { "current_release_date": "2019-07-11T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-192-05", "initial_release_date": "2019-07-11T00:00:00.000000Z", "revision_history": [ { "date": "2019-07-11T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-19-192-05 AVEVA Vijeo Citect and Citect SCADA Floating License Manager" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 2.3.0.0", "product": { "name": "Vijeo Citect and Citect SCADA Floating License Manager - Floating License Manager Version 2.3.0.0 and earlier", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Vijeo Citect and Citect SCADA Floating License Manager" } ], "category": "vendor", "name": "AVEVA Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-20031", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A denial of service vulnerability related to preemptive item deletion in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20031 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-20031" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AVEVA states that users who have deployed Floating License Manager Version 2.3.0.0 and earlier to manage their Software Licensing for Vijeo Citect or Citect SCADA (Version 7.30 and later) could be impacted.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Impacted users should upgrade to Floating License Manager (FLM) Version 2.3.1.0 as soon as possible.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "FLM Version 2.3.1.0 is already available via SESU (Schneider Electric Software Update tool).", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Details are described in the Schneider Electric Security Notification SEVD-2019-134-04.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-04" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-20032", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A denial of service vulnerability related to message decoding in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20032 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-20032" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AVEVA states that users who have deployed Floating License Manager Version 2.3.0.0 and earlier to manage their Software Licensing for Vijeo Citect or Citect SCADA (Version 7.30 and later) could be impacted.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Impacted users should upgrade to Floating License Manager (FLM) Version 2.3.1.0 as soon as possible.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "FLM Version 2.3.1.0 is already available via SESU (Schneider Electric Software Update tool).", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Details are described in the Schneider Electric Security Notification SEVD-2019-134-04.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-04" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-20033", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A remote code execution vulnerability in lmadmin and vendor daemon components allows a remote attacker to corrupt the memory by allocating/deallocating memory, loading lmadmin or the vendor daemon and causing the heartbeat between lmadmin and the vendor daemon to stop. This would force the vendor daemon to shut down. No exploit of this vulnerability has been demonstrated. CVE-2018-20033 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-20033" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AVEVA states that users who have deployed Floating License Manager Version 2.3.0.0 and earlier to manage their Software Licensing for Vijeo Citect or Citect SCADA (Version 7.30 and later) could be impacted.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Impacted users should upgrade to Floating License Manager (FLM) Version 2.3.1.0 as soon as possible.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "FLM Version 2.3.1.0 is already available via SESU (Schneider Electric Software Update tool).", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Details are described in the Schneider Electric Security Notification SEVD-2019-134-04.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-04" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-20034", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A denial of service vulnerability related to adding an item to a list in lmadmin and vendor daemon components allows a remote attacker to send a combination of messages to lmadmin or the vendor daemon, causing the heartbeat between lmadmin and the vendor daemon to stop and the vendor daemon to shut down. CVE-2018-20034 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-20034" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "AVEVA states that users who have deployed Floating License Manager Version 2.3.0.0 and earlier to manage their Software Licensing for Vijeo Citect or Citect SCADA (Version 7.30 and later) could be impacted.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Impacted users should upgrade to Floating License Manager (FLM) Version 2.3.1.0 as soon as possible.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "FLM Version 2.3.1.0 is already available via SESU (Schneider Electric Software Update tool).", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Details are described in the Schneider Electric Security Notification SEVD-2019-134-04.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-04" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.