icsa-22-090-06
Vulnerability from csaf_cisa
Published
2022-03-31 00:00
Modified
2022-03-31 00:00
Summary
General Electric Renewable Energy MDS Radios

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to control the configuration of the radio, join the network without proper authorization, or keep valid users from using the system correctly.
Critical infrastructure sectors
Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems
Countries/areas deployed
Worldwide
Company headquarters location
United State
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerabilities. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Exploitability
No known public exploits specifically target these vulnerabilities.



{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Reid Wightman"
        ],
        "organization": "Dragos",
        "summary": "reporting these vulnerabilities to GE"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities could allow an attacker to control the configuration of the radio, join the network without proper authorization, or keep valid users from using the system correctly.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater Systems",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "United State",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerabilities. Specifically, users should:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
        "title": "Recommended Practices"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-090-06 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-090-06.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-090-06 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-090-06"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      }
    ],
    "title": "General Electric Renewable Energy MDS Radios",
    "tracking": {
      "current_release_date": "2022-03-31T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-090-06",
      "initial_release_date": "2022-03-31T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-03-31T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-090-06 GE Renewable Energy MDS Radios"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c  rev. 8.3.0",
                "product": {
                  "name": "iNET/iNET II series radio: firmware versions prior to rev. 8.3.0",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "iNET/iNET II series radio"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c  rev. 6.4.7",
                "product": {
                  "name": "SD series radio: firmware versions prior to rev. 6.4.7",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "SD series radio"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c  rev. 1.2.6",
                "product": {
                  "name": "TD220MAX series radio: firmware versions prior to rev. 1.2.6",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "TD220MAX series radio"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c  rev. 2.0.16",
                "product": {
                  "name": "TD220X series radio: firmware versions prior to rev. 2.0.16",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "TD220X series radio"
          }
        ],
        "category": "vendor",
        "name": "General Electric (GE)"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2017-17562",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "This previously disclosed vulnerability in the GoAhead Webserver may allow remote code execution in iNET/iNET II, TD220X, and TD220MAX series radios.CVE-2017-17562 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-17562"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 10.0,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-24119",
      "cwe": {
        "id": "CWE-912",
        "name": "Hidden Functionality"
      },
      "notes": [
        {
          "category": "summary",
          "text": "iNET/iNET II series radios allow unauthenticated local and network access to the device configuration shell.CVE-2022-24119 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-24119"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 10.0,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-24116",
      "cwe": {
        "id": "CWE-326",
        "name": "Inadequate Encryption Strength"
      },
      "notes": [
        {
          "category": "summary",
          "text": "This vulnerability identifies a weakness in the wireless security software and chipset implementations in iNET/iNET II series radios.CVE-2022-24116 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-24116"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-24118",
      "cwe": {
        "id": "CWE-400",
        "name": "Uncontrolled Resource Consumption"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A feature can allow the use of an authentication code to cause iNET/iNET II, SD, TD220X, and TD220MAX series radios to reset back to the factory default configuration and reboot.CVE-2022-24118 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-24118"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-24120",
      "cwe": {
        "id": "CWE-256",
        "name": "Plaintext Storage of a Password"
      },
      "notes": [
        {
          "category": "summary",
          "text": "iNET and iNET II series radios store credentials in plaintext on the system flash memory.CVE-2022-24120 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-24120"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2022-24117",
      "cwe": {
        "id": "CWE-494",
        "name": "Download of Code Without Integrity Check"
      },
      "notes": [
        {
          "category": "summary",
          "text": "There is no cryptographic signature to verify authenticity of firmware.CVE-2022-24117 has been assigned to this vulnerability. A CVSS v3 base score of 8.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H).",
          "title": "Vulnerability Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-24117"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "mitigation",
          "details": "iNET/iNET II series radio firmware rev.8.3.0",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=iNETII\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "SD series radio firmware rev. 6.4.7",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=SDseries\u0026type=21"
        },
        {
          "category": "vendor_fix",
          "details": "TD220X series radio firmware rev. 2.0.16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "TD220MAX series radio firmware rev. 1.2.6",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/app/resources.aspx?prod=td-series\u0026type=21"
        },
        {
          "category": "mitigation",
          "details": "GE also recommends the use of other protections inside the radio such as MAC address allow-listing, IEEE 802.1x authentication, or encrypt traffic at the application level with protocols such as HTTPS or SSH. GE provides additional mitigations and information about these vulnerabilities in GE publication number: GES-2021-18 TD220 - GES-2021-17 iNET - GES-2021-16",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ],
          "url": "https://www.gegridsolutions.com/communications/wireless.htm"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.