icsa-22-132-09
Vulnerability from csaf_cisa
Published
2022-05-12 00:00
Modified
2022-05-12 00:00
Summary
Siemens JT2GO and Teamcenter Visualization

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to trick a user to open a malicious file (crafted as CGM, TIFF or TG4) with any of the affected products, which could lead the application to crash or to arbitrary code execution.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.



{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Jin Huang"
        ],
        "organization": "ADLab of Venustech",
        "summary": "reporting these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities could allow an attacker to trick a user to open a malicious file (crafted as CGM, TIFF or TG4) with any of the affected products, which could lead the application to crash or to arbitrary code execution.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "other",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Exploitability"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "external",
        "summary": "SSA-553086: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-553086.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-09 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-09.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-22-132-09 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-09"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
      },
      {
        "category": "external",
        "summary": "SSA-553086: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553086.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-553086: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-553086.txt"
      }
    ],
    "title": "Siemens JT2GO and Teamcenter Visualization",
    "tracking": {
      "current_release_date": "2022-05-12T00:00:00.000000Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-22-132-09",
      "initial_release_date": "2022-05-12T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2022-05-12T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "ICSA-22-132-09 Siemens JT2GO and Teamcenter Visualization"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V13.3.0.3",
                "product": {
                  "name": "JT2Go",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "JT2Go"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V13.3.0.3",
                "product": {
                  "name": "Teamcenter Visualization V13.3",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter Visualization V13.3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V14.0.0.1",
                "product": {
                  "name": "Teamcenter Visualization V14.0",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter Visualization V14.0"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-29028",
      "cwe": {
        "id": "CWE-835",
        "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The Tiff_Loader.dll is vulnerable to infinite loop condition while parsing specially crafted TIFF files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29028 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29028 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29028 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29028 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29028.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29028"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29028"
    },
    {
      "cve": "CVE-2022-29029",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29029 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29029 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29029 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29029 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29029.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29029"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29029"
    },
    {
      "cve": "CVE-2022-29030",
      "cwe": {
        "id": "CWE-680",
        "name": "Integer Overflow to Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The Mono_Loader.dll library is vulnerable to integer overflow condition while parsing specially crafted TG4 files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29030 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29030 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29030 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29030 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29030.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29030"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29030"
    },
    {
      "cve": "CVE-2022-29031",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The CGM_NIST_Loader.dll contains a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29031 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29031 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29031 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29031 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29031.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29031"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29031"
    },
    {
      "cve": "CVE-2022-29032",
      "cwe": {
        "id": "CWE-415",
        "name": "Double Free"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29032 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29032 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29032 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29032 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29032.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29032"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29032"
    },
    {
      "cve": "CVE-2022-29033",
      "cwe": {
        "id": "CWE-824",
        "name": "Access of Uninitialized Pointer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The CGM_NIST_Loader.dll library is vulnerable to uninitialized pointer free while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-29033 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2022-29033 - Teamcenter Visualization V13.3",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29033 - Teamcenter Visualization V14.0",
          "url": "https://support.sw.siemens.com/"
        },
        {
          "summary": "CVE-2022-29033 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-29033.json"
        },
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29033"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.3 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.1 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in affected products",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003"
          ]
        }
      ],
      "title": "CVE-2022-29033"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.