ICSA-23-012-04
Vulnerability from csaf_cisa - Published: 2023-01-12 00:00 - Updated: 2023-01-12 00:00Summary
Panasonic Sanyo CCTV Network Camera
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of this vulnerability could allow attackers to perform actions via HTTP without validity checks.
Critical infrastructure sectors
Commercial Facilities
Countries/areas deployed
Worldwide
Company headquarters location
Japan
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
{
"document": {
"acknowledgments": [
{
"names": [
"Gjoko Krstic"
],
"organization": "Zero Science Lab",
"summary": "publishing a public proof of concept"
},
{
"organization": "CISA",
"summary": "discovering a public PoC as authored by Gjoko Krstic of Zero Science Lab"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow attackers to perform actions via HTTP without validity checks. ",
"title": "Risk evaluation"
},
{
"category": "other",
"text": " Commercial Facilities ",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": " Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": " Japan",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-23-012-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-012-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-012-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-012-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
}
],
"title": "Panasonic Sanyo CCTV Network Camera",
"tracking": {
"current_release_date": "2023-01-12T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-012-04",
"initial_release_date": "2023-01-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-01-12T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": " 2.03-06",
"product": {
"name": "Sanyo CCTV Network Camera: VCC-HD5600P version 2.03-06",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "CC-HD5600P"
},
{
"branches": [
{
"category": "product_version",
"name": " 2.03-08",
"product": {
"name": "Sanyo CCTV Network Camera: VDC-HD3300P version 2.03-08",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "DC-HD3300P"
},
{
"branches": [
{
"category": "product_version",
"name": "1.02-05",
"product": {
"name": "Sanyo CCTV Network Camera: VDC-HD3300P version 1.02-05",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "DC-HD3300P"
},
{
"branches": [
{
"category": "product_version",
"name": " 2.03-02",
"product": {
"name": "Sanyo CCTV Network Camera: VCC-HD3300 version 2.03-02",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "CC-HD3300"
},
{
"branches": [
{
"category": "product_version",
"name": " 2.03-00",
"product": {
"name": "Sanyo CCTV Network Camera: VDC-HD3100P version 2.03-00",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "CC-HD2100P"
},
{
"branches": [
{
"category": "product_version",
"name": "2.03-02",
"product": {
"name": "Sanyo CCTV Network Camera: VCC-HD2100P version 2.03-02",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "CC-HD2100P"
}
],
"category": "vendor",
"name": "Panasonic"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-4621",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "summary",
"text": "Panasonic Sanyo CCTV Network Cameras versions 1.02-05 and 2.03-0x are vulnerable to CSRFs that can be exploited to allow an attacker to perform changes with administrator level privileges.-CVE-2022-4621 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-4621"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Panasonic has stated that Sanyo Electric Camera Systems are no longer in production and released this advisory. All repair requests and other support requests via email or phone will longer be available.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://archives.connect.panasonic.com/security/sanyo/index.html"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…