Summary
Mitsubishi Electric MELSEC-Q/L Series (Update B)
Notes
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow a remote attacker to be able to read arbitrary information or execute malicious code on a target product by sending a specially crafted packet.
Critical infrastructure sectors
Critical Manufacturing
Countries/areas deployed
Worldwide
Company headquarters location
Japan
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
Recommended Practices
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
{ "document": { "acknowledgments": [ { "names": [ "Anton Dorfman" ], "organization": "Positive Technologies", "summary": "reporting these vulnerabilities to Mitsubishi Electric" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow a remote attacker to be able to read arbitrary information or execute malicious code on a target product by sending a specially crafted packet.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-24-074-14 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-074-14.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-24-074-14 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-14" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Mitsubishi Electric MELSEC-Q/L Series (Update B)", "tracking": { "current_release_date": "2024-06-13T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-24-074-14", "initial_release_date": "2024-03-14T06:00:00.000000Z", "revision_history": [ { "date": "2024-03-14T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2024-05-16T06:00:00.000000Z", "legacy_version": "Update A", "number": "2", "summary": "Update A - Update to the affected products and mitigations" }, { "date": "2024-06-13T06:00:00.000000Z", "legacy_version": "Update B", "number": "3", "summary": "Update B - Update to the affected products and mitigations" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q03UDECPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "MELSEC-Q Series Q03UDECPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q04UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "MELSEC-Q Series Q04UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q06UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "MELSEC-Q Series Q06UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q10UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "MELSEC-Q Series Q10UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q13UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "MELSEC-Q Series Q13UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q20UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "MELSEC-Q Series Q20UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q26UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "MELSEC-Q Series Q26UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q50UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "MELSEC-Q Series Q50UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q100UDEHCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "MELSEC-Q Series Q100UDEHCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q03UDVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "MELSEC-Q Series Q03UDVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q04UDVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "MELSEC-Q Series Q04UDVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q06UDVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "MELSEC-Q Series Q06UDVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q13UDVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "MELSEC-Q Series Q13UDVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q26UDVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "MELSEC-Q Series Q26UDVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q04UDPVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "MELSEC-Q Series Q04UDPVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q06UDPVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "MELSEC-Q Series Q06UDPVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q13UDPVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "MELSEC-Q Series Q13UDPVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26061\"", "product": { "name": "Mitsubishi Electric MELSEC-Q Series Q26UDPVCPU: \u003c=The_first_5_digits_of_serial_No._\"26061\"", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "MELSEC-Q Series Q26UDPVCPU" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26041\"", "product": { "name": "Mitsubishi Electric MELSEC-L Series L02CPU(-P): \u003c=The_first_5_digits_of_serial_No._\"26041\"", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "MELSEC-L Series L02CPU(-P)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26041\"", "product": { "name": "Mitsubishi Electric MELSEC-L Series L06CPU(-P): \u003c=The_first_5_digits_of_serial_No._\"26041\"", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "MELSEC-L Series L06CPU(-P)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26041\"", "product": { "name": "Mitsubishi Electric MELSEC-L Series L26CPU(-P): \u003c=The_first_5_digits_of_serial_No._\"26041\"", "product_id": "CSAFPID-0021" } } ], "category": "product_name", "name": "MELSEC-L Series L26CPU(-P)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=The_first_5_digits_of_serial_No._\"26041\"", "product": { "name": "Mitsubishi Electric MELSEC-L Series L26CPU-(P)BT: \u003c=The_first_5_digits_of_serial_No._\"26041\"", "product_id": "CSAFPID-0022" } } ], "category": "product_name", "name": "MELSEC-L Series L26CPU-(P)BT" } ], "category": "vendor", "name": "Mitsubishi Electric" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-0802", "cwe": { "id": "CWE-468", "name": "Incorrect Pointer Scaling" }, "notes": [ { "category": "summary", "text": "In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to read arbitrary information from a target product or execute malicious code on a target product by sending a specially crafted packet.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-0802" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric released the fixed version of the product:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "vendor_fix", "details": "MELSEC-Q Series Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q03/04/06/13/26UDVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q04/06/13/26UDPVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "MELSEC-L Series L02/06/26CPU(-P), L26CPU-(P)BT: firmware versions where the first 5 digits of serial No. \"26042\" or later", "product_ids": [ "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that users consider replacing with MELSEC iQ-R Series.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use within a LAN and block access from untrusted networks and hosts through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Restrict physical access to the affected product as well as to the personal computers and the network devices that can communicate with it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Install antivirus software on your personal computer that can access the affected product.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "For specific additional details, see Mitsubishi Electric advisory 2023-024.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ] }, { "cve": "CVE-2024-0803", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a target product by sending a specially crafted packet", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-0803" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric released the fixed version of the product:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "vendor_fix", "details": "MELSEC-Q Series Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q03/04/06/13/26UDVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q04/06/13/26UDPVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "MELSEC-L Series L02/06/26CPU(-P), L26CPU-(P)BT: firmware versions where the first 5 digits of serial No. \"26042\" or later", "product_ids": [ "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that users consider replacing with MELSEC iQ-R Series.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use within a LAN and block access from untrusted networks and hosts through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Restrict physical access to the affected product as well as to the personal computers and the network devices that can communicate with it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Install antivirus software on your personal computer that can access the affected product.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "For specific additional details, see Mitsubishi Electric advisory 2023-024.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ] }, { "cve": "CVE-2024-1915", "cwe": { "id": "CWE-468", "name": "Incorrect Pointer Scaling" }, "notes": [ { "category": "summary", "text": "In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a target product by sending a specially crafted packet", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-1915" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric released the fixed version of the product:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "vendor_fix", "details": "MELSEC-Q Series Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q03/04/06/13/26UDVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q04/06/13/26UDPVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "MELSEC-L Series L02/06/26CPU(-P), L26CPU-(P)BT: firmware versions where the first 5 digits of serial No. \"26042\" or later", "product_ids": [ "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that users consider replacing with MELSEC iQ-R Series.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use within a LAN and block access from untrusted networks and hosts through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Restrict physical access to the affected product as well as to the personal computers and the network devices that can communicate with it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Install antivirus software on your personal computer that can access the affected product.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "For specific additional details, see Mitsubishi Electric advisory 2023-024.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ] }, { "cve": "CVE-2024-1916", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a target product by sending a specially crafted packet", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-1916" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric released the fixed version of the product:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "vendor_fix", "details": "MELSEC-Q Series Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q03/04/06/13/26UDVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q04/06/13/26UDPVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "MELSEC-L Series L02/06/26CPU(-P), L26CPU-(P)BT: firmware versions where the first 5 digits of serial No. \"26042\" or later", "product_ids": [ "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that users consider replacing with MELSEC iQ-R Series.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use within a LAN and block access from untrusted networks and hosts through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Restrict physical access to the affected product as well as to the personal computers and the network devices that can communicate with it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Install antivirus software on your personal computer that can access the affected product.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "For specific additional details, see Mitsubishi Electric advisory 2023-024.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ] }, { "cve": "CVE-2024-1917", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "In the Mitsubishi Electric MELSEC-Q/L Series a remote attacker may be able to execute malicious code on a target product by sending a specially crafted packet", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2024-1917" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric released the fixed version of the product:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "vendor_fix", "details": "MELSEC-Q Series Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q03/04/06/13/26UDVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014" ] }, { "category": "mitigation", "details": "MELSEC-Q Series Q04/06/13/26UDPVCPU: firmware versions where the first 5 digits of serial No. \"26062\" or later", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018" ] }, { "category": "mitigation", "details": "MELSEC-L Series L02/06/26CPU(-P), L26CPU-(P)BT: firmware versions where the first 5 digits of serial No. \"26042\" or later", "product_ids": [ "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that users consider replacing with MELSEC iQ-R Series.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use a firewall, virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Use within a LAN and block access from untrusted networks and hosts through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Restrict physical access to the affected product as well as to the personal computers and the network devices that can communicate with it.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "Install antivirus software on your personal computer that can access the affected product.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] }, { "category": "mitigation", "details": "For specific additional details, see Mitsubishi Electric advisory 2023-024.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-024_en.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022" ] } ] } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.