ICSA-24-235-04
Vulnerability from csaf_cisa - Published: 2024-08-22 06:00 - Updated: 2024-08-22 06:00Summary
Avtec Outpost 0810
Notes
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to gain administrative privileges on the affected devices.
Critical infrastructure sectors
Communications Sector
Countries/areas deployed
Worldwide
Company headquarters location
United States
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:
Recommended Practices
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.
{
"document": {
"acknowledgments": [
{
"names": [
"Jonathan Fournier"
],
"organization": "Field Effect",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker to gain administrative privileges on the affected devices.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Communications Sector",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-24-235-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-235-04.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-24-235-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-235-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Avtec Outpost 0810",
"tracking": {
"current_release_date": "2024-08-22T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-235-04",
"initial_release_date": "2024-08-22T06:00:00.000000Z",
"revision_history": [
{
"date": "2024-08-22T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cv5.0.0",
"product": {
"name": "Avtec Outpost 0810: \u003cv5.0.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Outpost 0810"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cv5.0.0",
"product": {
"name": "Avtec Outpost Uploader Utility: \u003cv5.0.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Outpost Uploader Utility"
}
],
"category": "vendor",
"name": "Avtec"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-39776",
"cwe": {
"id": "CWE-219",
"name": "Storage of File with Sensitive Data Under Web Root"
},
"notes": [
{
"category": "summary",
"text": "Avtec Outpost stores sensitive information in an insecure location without proper access controls in place.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-39776"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Avtec recommends users update to Outpost v5.0 to resolve.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "When upgrading to Outpost Version 5.0.0 or later, you must reset your list of users to the default. More information and instructions can be found on Avtec\u0027s Outpost Uploader Utility User Guide for more information.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://connect.avtecinc.com/bundle/Outpost_Uploader_Utility_User_Guide/page/Content/Outpost_User_Guide/Reset_Web_Auth.html"
},
{
"category": "mitigation",
"details": "Restrict access to port 80 or disable web interface if possible.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Additionally, Avtec recommends checking devices for Scout firmware versions prior to 5.8.1, which was commonly coupled with Outpost firmware. If so, the devices may also need to be updated to the latest firmware. For more information, please visit Scout Release Notes",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://connect.avtecinc.com/bundle/Scout_Release_Notes_5_8/resource/Release_Notes_Scout.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2024-42418",
"cwe": {
"id": "CWE-321",
"name": "Use of Hard-coded Cryptographic Key"
},
"notes": [
{
"category": "summary",
"text": "Avtec Outpost uses a default cryptographic key that can be used to decrypt sensitive information",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-42418"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Avtec recommends users update to Outpost v5.0 to resolve.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "When upgrading to Outpost Version 5.0.0 or later, you must reset your list of users to the default. More information and instructions can be found on Avtec\u0027s Outpost Uploader Utility User Guide for more information.",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://connect.avtecinc.com/bundle/Outpost_Uploader_Utility_User_Guide/page/Content/Outpost_User_Guide/Reset_Web_Auth.html"
},
{
"category": "mitigation",
"details": "Restrict access to port 80 or disable web interface if possible.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Additionally, Avtec recommends checking devices for Scout firmware versions prior to 5.8.1, which was commonly coupled with Outpost firmware. If so, the devices may also need to be updated to the latest firmware. For more information, please visit Scout Release Notes",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://connect.avtecinc.com/bundle/Scout_Release_Notes_5_8/resource/Release_Notes_Scout.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…