ICSA-25-037-02
Vulnerability from csaf_cisa - Published: 2025-01-14 07:00 - Updated: 2026-04-02 06:00Summary
Schneider Electric EcoStruxure (Update D)
Notes
General Security Recommendations: We strongly recommend the following industry cybersecurity best practices.
https://www.se.com/us/en/download/document/7EN52-0390/
* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
* Place all controllers in locked cabinets and never leave them in the “Program” mode.
* Never connect programming software to any network other than the network intended for that device.
* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For More Information: This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.
Customers should use appropriate patching methodologies when applying these patches to their systems. We
strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and
Development environment or on an offline infrastructure. Contact Schneider Electric’s Customer Care Center if
you need assistance removing a patch.
For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER: THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric: Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and
sustainability for all. We call this Life Is On.
Our mission is to be the trusted partner in Sustainability and Efficiency.
We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart
industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep
domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,
software and services, delivering digital twins to enable profitable growth for our customers.
We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries
to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our
meaningful purpose of a sustainable future for all.
Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric’s Technical Support at supportRO@se.com if you need assistance.
Overview: Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component.
Many vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers.
Failure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could
lead to the execution of a malicious DLL with elevated privilege.
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-014-07 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.
Critical infrastructure sectors: Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems, Water and Wastewater
Countries/areas deployed: Worldwide
Company headquarters location: France
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
7.8 (High)
Vendor Fix
Version 16.2 of EcoStruxure™ Control Expert includes a fix for this vulnerability and is
available for download here:
https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/
Reboot the computer after installation is completed.
https://www.se.com/ww/en/product-range/548-ecostr…
Vendor Fix
Version V7.0.18 of EcoStruxure™ Architecture Builder includes a fix for this vulnerability
and is available for download here:
https://www.se.com/ww/en/product-range/195445393-ecostruxure-architecture-builder/ -
software-and-firmware
https://www.se.com/ww/en/product-range/195445393-…
Vendor Fix
Version V4.0SP1 of EcoStruxure™ Control Expert Asset Link includes a fix for this
vulnerability and is available for download here:
https://www.se.com/ww/en/download/document/ECALV40SP1/
https://www.se.com/ww/en/product-range/548-ecostr…
Vendor Fix
Version V6.3SP1 HF1 of Vijeo Designer includes a fix for this vulnerability. Please contact
your Schneider Electric Customer Support https://www.se.com/ww/en/work/support/country-selector/contact-us.jsp to get Vijeo Designer version V6.3SP1 HF1
software.
Mitigation
Schneider Electric is establishing a remediation plan for all
future versions of the following that will include a fix for this
vulnerability:
• EcoStruxure™ Process Expert
• EcoStruxure™ OPC UA Server Expert
• EcoStruxure™ Machine SCADA Expert - Asset
Link
• EcoStruxure™ Operator Terminal Expert
• EcoStruxure™ Machine Expert including
EcoStruxure™ Machine Expert Safety
• EcoStruxure™ Machine Expert Twin
• Zelio Soft 2
We will update this document when the remediation is
available. Until then, customers should immediately apply
the following mitigations to reduce the risk of exploit:
• Limit authenticated user access to the workstation
and implement existing User Account Control
practices.
• Follow workstation, network and site-hardening
guidelines in the Recommended Cybersecurity
Best Practices guide available for download here https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true .
https://www.se.com/ww/en/download/document/7EN52-…
Mitigation
If customers choose not to apply the remediation provided above, they should immediately apply the following
mitigations to reduce the risk of exploit:
• Limit authenticated user access to the workstation and implement existing User Account Control
practices.
• Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best
Practices guide available for download here.
https://www.se.com/ww/en/download/document/7EN52-…
Vendor Fix
Version 2023 (v4.8.0.5715) of EcoStruxure™ Process Expert includes a fix for this
vulnerability and is available for download here:
https://www.se.com/ww/en/product-country-selector/?pageType=productrange&
sourceId=65406
Uninstall previous version 2023 (v4.8.0.5115) before installing Version 2023
(v4.8.0.5715).
Version string can be found on engineering server console.
https://www.se.com/ww/en/product-country-selector…
Vendor Fix
Version 2023 (v4.8.0.5715) of EcoStruxure™ Process Expert includes a fix for
this vulnerability and is available for download here:
https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=65406
https://www.se.com/ww/en/product-country-selector…
Vendor Fix
Version 4.0 of EcoStruxure™ Operator Terminal Expert includes a fix for this
vulnerability and is available for download here:
https://www.se.com/ww/en/product-range/62621-ecostruxure-operator-terminal-expert/#software-and-firmware
https://www.se.com/ww/en/product-range/62621-ecos…
Vendor Fix
Version 4.0 of Pro-face BLUE includes a fix for this vulnerability and is available
for download here:
https://www.proface.com/en/hmi_design_studio/blue/page/installer
https://www.proface.com/en/hmi_design_studio/blue…
Vendor Fix
Version 5.4.3 of Zelio Soft 2 includes a fix for this vulnerability and is available for download here:
https://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware
https://www.se.com/ww/en/product-range/542-zelio-…
Vendor Fix
Version SV2.01SP3 of EcoStruxure™ OPC UA Server Expert includes a fix for this vulnerability and is available for download here:
https://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware
https://www.se.com/ww/en/product-range/66388-ecos…
Vendor Fix
Version v2.5.0.1 of EcoStruxure™ Machine Expert includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here:
https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/
https://www.se.com/ww/en/download/document/ESEMAC…
Vendor Fix
Version v2.3 of EcoStruxure™ Machine Expert Twin includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here:
https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/
https://www.se.com/ww/en/download/document/ESEMAC…
References
Acknowledgments
Schneider Electric CPCERT
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reported this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\n\n Customers should use appropriate patching methodologies when applying these patches to their systems. We\r\nstrongly recommend the use of back-ups and evaluating the impact of these patches in a Test and\r\nDevelopment environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if\r\nyou need assistance removing a patch.\n\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "Schneider\u0027s purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and\r\nsustainability for all. We call this Life Is On.\n\nOur mission is to be the trusted partner in Sustainability and Efficiency.\n\nWe are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart\r\nindustries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep\r\ndomain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation,\r\nsoftware and services, delivering digital twins to enable profitable growth for our customers.\n\nWe are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries\r\nto ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our\r\nmeaningful purpose of a sustainable future for all.",
"title": "About Schneider Electric"
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Technical Support at supportRO@se.com if you need assistance."
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component. \r\nMany vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers.\r\nFailure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could \r\nlead to the execution of a malicious DLL with elevated privilege.",
"title": "Overview"
},
{
"category": "legal_disclaimer",
"text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
"title": "Legal Notice and Terms of Use"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-014-07 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems, Water and Wastewater",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "FlexNet Publisher Vulnerability - SEVD-2025-014-07 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-014-07.json"
},
{
"category": "self",
"summary": "FlexNet Publisher Vulnerability - SEVD-2025-014-07 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-07.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/ww/en/download/document/7EN52-0390"
},
{
"category": "external",
"summary": "Revenera Advisory",
"url": "https://community.revenera.com/s/article/cve-2024-2658-flexnet-publisher-potential-local-privilege-escalation-issue"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-037-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-037-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-037-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-037-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
}
],
"title": "Schneider Electric EcoStruxure (Update D)",
"tracking": {
"current_release_date": "2026-04-02T06:00:00.000000Z",
"generator": {
"date": "2026-04-01T20:58:41.577424Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.5.0"
}
},
"id": "ICSA-25-037-02",
"initial_release_date": "2025-01-14T07:00:00.000000Z",
"revision_history": [
{
"date": "2025-01-14T07:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Original Release"
},
{
"date": "2025-02-06T07:00:00.000000Z",
"legacy_version": "Additional Release 1",
"number": "2",
"summary": "CISA Republication - Initial Publication"
},
{
"date": "2025-02-11T06:00:00.000000Z",
"legacy_version": "Additional Release 2",
"number": "3",
"summary": "A remediation is available for the EcoStruxure\u2122 Process Expert offer. The EcoStruxure\u2122 Process Expert for AVEVA System Platform offer is added to the \u201cAffected Product and Versions\u201d section"
},
{
"date": "2025-03-06T07:00:00.000000Z",
"legacy_version": "Additional Release 3",
"number": "4",
"summary": "CISA Republication - Update A - A remediation is available for EcoStruxure Process Expert. The EcoStruxure Process Expert for AVEVA System Platform offer is added to the Affected Products."
},
{
"date": "2025-07-08T04:00:00.000000Z",
"legacy_version": "Additional Release 4",
"number": "5",
"summary": "Pro-face BLUE is added to the \u201cAffected Product and Versions\u201d section. Remediations are now available for EcoStruxure\u2122Control Expert, EcoStruxure\u2122 Operator Terminal Expert and Pro-face BLUE offers. Updated the link to the fix of EcoStruxure\u2122 Control Expert Asset Link offer"
},
{
"date": "2025-07-15T06:00:00.000000Z",
"legacy_version": "Additional Release 5",
"number": "6",
"summary": "CISA Republication - Update B - Pro-face BLUE is added to the \"Affected Products\" section. Remediations are now available for EcoStruxure Control Expert, EcoStruxure Operator Terminal Expert and Pro-face BLUE offers. Updated the link to the fix of EcoStruxure Control Expert Asset Link offer."
},
{
"date": "2025-10-14T07:00:00.000000Z",
"legacy_version": "Additional Release 6",
"number": "7",
"summary": "A remediation is now available for Zelio Soft 2 and EcoStruxure\u2122 OPC UA Server Expert offers"
},
{
"date": "2025-10-23T06:00:00.000000Z",
"legacy_version": "Additional Release 7",
"number": "8",
"summary": "CISA Republication - Update C - Remediations are now available for Zelio Soft 2 and EcoStruxure OPC UA Server Expert offers."
},
{
"date": "2025-11-11T08:00:00.000000Z",
"legacy_version": "Additional Release 8",
"number": "9",
"summary": "CVE, CWE, \u0026 CVSS Score information was added."
},
{
"date": "2026-03-10T07:00:00.000000Z",
"legacy_version": "Additional Release 9",
"number": "10",
"summary": "A remediation is now available for EcoStruxure\u2122 Machine Expert and EcoStruxure\u2122 Machine Expert Twin"
},
{
"date": "2026-04-02T06:00:00.000000Z",
"legacy_version": "Latest Updated CISA Republication",
"number": "11",
"summary": "CISA Republication update based on Schneider Electric CPCERT SEVD-2025-014-07 advisory"
}
],
"status": "final",
"version": "11"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c16.2",
"product": {
"name": "EcoStruxure\u2122 Control Expert Versions prior to V16.2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2023_v4.8.0.5715",
"product": {
"name": "EcoStruxure\u2122 Process Expert Versions prior to 2023 (v4.8.0.5715)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV2.01SP3",
"product": {
"name": "EcoStruxure\u2122 OPC UA Server Expert Versions prior to SV2.01SP3",
"product_id": "CSAFPID-0003"
}
},
{
"category": "product_version_range",
"name": "SV2.01SP3",
"product": {
"name": "EcoStruxure\u2122 OPC UA Server Expert Version SV2.01SP3",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 OPC UA Server Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0_SP1",
"product": {
"name": "EcoStruxure\u2122 Control Expert Asset Link Versions prior to V4.0 SP1",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert Asset Link"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "EcoStruxure\u2122 Machine SCADA Expert Asset Link All versions",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine SCADA Expert Asset Link"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c7.0.18",
"product": {
"name": "EcoStruxure\u2122 Architecture Builder Versions prior to V7.0.18",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Architecture Builder"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0",
"product": {
"name": "EcoStruxure\u2122 Operator Terminal Expert Versions prior to V4.0",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Operator Terminal Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c6.3SP1_HF1",
"product": {
"name": "Vijeo Designer Version prior to V6.3SP1 HF1",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "Vijeo Designer"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.5.0.1",
"product": {
"name": "EcoStruxure\u2122 Machine Expert versions prior to v2.5.0.1",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "2.5.0.1",
"product": {
"name": "EcoStruxure\u2122 Machine Expert version v2.5.0.1",
"product_id": "CSAFPID-0011"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2.3",
"product": {
"name": "EcoStruxure\u2122 Machine Expert Twin versions prior to v2.3",
"product_id": "CSAFPID-0012"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine Expert Twin"
},
{
"branches": [
{
"category": "product_version_range",
"name": "2.3",
"product": {
"name": "EcoStruxure\u2122 Machine Expert Twin version v2.3",
"product_id": "CSAFPID-0013"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine Expert Twin"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.4.3",
"product": {
"name": "Zelio Soft 2 Versions prior to v5.4.3",
"product_id": "CSAFPID-0014"
}
},
{
"category": "product_version",
"name": "5.4.3",
"product": {
"name": "Zelio Soft 2 Version v5.4.3",
"product_id": "CSAFPID-0015"
}
}
],
"category": "product_name",
"name": "Zelio Soft 2"
},
{
"branches": [
{
"category": "product_version",
"name": "16.2",
"product": {
"name": "EcoStruxure\u2122 Control Expert Version V16.2",
"product_id": "CSAFPID-0016"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "7.0.18",
"product": {
"name": "EcoStruxure\u2122 Architecture Builder Version V7.0.18",
"product_id": "CSAFPID-0017"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Architecture Builder"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0SP1",
"product": {
"name": "EcoStruxure\u2122 Control Expert Asset Link Version V4.0SP1",
"product_id": "CSAFPID-0018"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert Asset Link"
},
{
"branches": [
{
"category": "product_version",
"name": "6.3SP1_HF1",
"product": {
"name": "Vijeo Designer Version V6.3SP1 HF1",
"product_id": "CSAFPID-0019"
}
}
],
"category": "product_name",
"name": "Vijeo Designer"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "EcoStruxure\u2122 Process Expert for AVEVA System Platform All versions",
"product_id": "CSAFPID-0020"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert for AVEVA System Platform"
},
{
"branches": [
{
"category": "product_version",
"name": "2023_v4.8.0.5715",
"product": {
"name": "EcoStruxure\u2122 Process Expert Version 2023 (v4.8.0.5715)",
"product_id": "CSAFPID-0021"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert 2023"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c4.0",
"product": {
"name": "Pro-face BLUE Versions prior to V4.0",
"product_id": "CSAFPID-0022"
}
}
],
"category": "product_name",
"name": "Pro-face BLUE"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0",
"product": {
"name": "Pro-face BLUE Version V4.0",
"product_id": "CSAFPID-0023"
}
}
],
"category": "product_name",
"name": "Pro-face BLUE"
},
{
"branches": [
{
"category": "product_version",
"name": "4.0",
"product": {
"name": "EcoStruxure\u2122 Operator Terminal Expert Version V4.0",
"product_id": "CSAFPID-0024"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Operator Terminal Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c2023",
"product": {
"name": "EcoStruxure\u2122 Process Expert Versions prior to 2023",
"product_id": "CSAFPID-0025"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "EcoStruxure\u2122 Machine Expert Safety All versions",
"product_id": "CSAFPID-0026"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Machine Expert Safety"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-2658",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "details",
"text": "Vulnerability disclosed by Revenera group in FlexNet Publisher impact Schneider Electric software. \nAdditional information about the vulnerability CVE-2024-2658 can be found in the Revenera Advisory at:\nhttps://community.revenera.com/s/article/cve-2024-2658-flexnet-publisher-potential-local-privilege-escalation-issue",
"title": "Vulnerability Details"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 8.5 | High | [CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N)",
"title": "CVSS v4.0 Score"
}
],
"product_status": {
"fixed": [
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0021",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0015",
"CSAFPID-0004",
"CSAFPID-0011",
"CSAFPID-0013"
],
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0020",
"CSAFPID-0022",
"CSAFPID-0025",
"CSAFPID-0026"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-2658"
},
{
"category": "external",
"summary": "cwe.mitre.org",
"url": "https://cwe.mitre.org/data/definitions/427.html"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Version 16.2 of EcoStruxure\u2122 Control Expert includes a fix for this vulnerability and is \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/ \r\nReboot the computer after installation is completed.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/"
},
{
"category": "vendor_fix",
"details": "Version V7.0.18 of EcoStruxure\u2122 Architecture Builder includes a fix for this vulnerability\r\nand is available for download here:\r\nhttps://www.se.com/ww/en/product-range/195445393-ecostruxure-architecture-builder/ -\r\nsoftware-and-firmware",
"product_ids": [
"CSAFPID-0007"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/195445393-ecostruxure-architecture-builder/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version V4.0SP1 of EcoStruxure\u2122 Control Expert Asset Link includes a fix for this \r\nvulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/ECALV40SP1/",
"product_ids": [
"CSAFPID-0005"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/"
},
{
"category": "vendor_fix",
"details": "Version V6.3SP1 HF1 of Vijeo Designer includes a fix for this vulnerability. Please contact \r\nyour Schneider Electric Customer Support https://www.se.com/ww/en/work/support/country-selector/contact-us.jsp to get Vijeo Designer version V6.3SP1 HF1\r\nsoftware.",
"product_ids": [
"CSAFPID-0009"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "Schneider Electric is establishing a remediation plan for all \r\nfuture versions of the following that will include a fix for this\r\nvulnerability:\r\n\u2022 EcoStruxure\u2122 Process Expert\r\n\u2022 EcoStruxure\u2122 OPC UA Server Expert\r\n\u2022 EcoStruxure\u2122 Machine SCADA Expert - Asset \r\nLink\r\n\u2022 EcoStruxure\u2122 Operator Terminal Expert\r\n\u2022 EcoStruxure\u2122 Machine Expert including \r\nEcoStruxure\u2122 Machine Expert Safety\r\n\u2022 EcoStruxure\u2122 Machine Expert Twin\r\n\u2022 Zelio Soft 2\r\nWe will update this document when the remediation is \r\navailable. Until then, customers should immediately apply \r\nthe following mitigations to reduce the risk of exploit:\r\n\u2022 Limit authenticated user access to the workstation \r\nand implement existing User Account Control \r\npractices.\r\n\u2022 Follow workstation, network and site-hardening \r\nguidelines in the Recommended Cybersecurity \r\nBest Practices guide available for download here https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true .",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0020",
"CSAFPID-0026"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following\r\nmitigations to reduce the risk of exploit:\r\n\u2022 Limit authenticated user access to the workstation and implement existing User Account Control\r\npractices.\r\n\u2022 Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best\r\nPractices guide available for download here.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0022",
"CSAFPID-0025"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/7EN52-0390/?ssr=true"
},
{
"category": "vendor_fix",
"details": "Version 2023 (v4.8.0.5715) of EcoStruxure\u2122 Process Expert includes a fix for this \r\nvulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-country-selector/?pageType=productrange\u0026\r\nsourceId=65406 \r\nUninstall previous version 2023 (v4.8.0.5115) before installing Version 2023 \r\n(v4.8.0.5715).\r\nVersion string can be found on engineering server console.",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406"
},
{
"category": "vendor_fix",
"details": "Version 2023 (v4.8.0.5715) of EcoStruxure\u2122 Process Expert includes a fix for \r\nthis vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406",
"product_ids": [
"CSAFPID-0025"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-country-selector/?pageType=product-range\u0026sourceId=65406"
},
{
"category": "vendor_fix",
"details": "Version 4.0 of EcoStruxure\u2122 Operator Terminal Expert includes a fix for this \r\nvulnerability and is available for download here: \r\nhttps://www.se.com/ww/en/product-range/62621-ecostruxure-operator-terminal-expert/#software-and-firmware",
"product_ids": [
"CSAFPID-0008"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/62621-ecostruxure-operator-terminal-expert/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version 4.0 of Pro-face BLUE includes a fix for this vulnerability and is available \r\nfor download here:\r\nhttps://www.proface.com/en/hmi_design_studio/blue/page/installer",
"product_ids": [
"CSAFPID-0022"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/hmi_design_studio/blue/page/installer"
},
{
"category": "vendor_fix",
"details": "Version 5.4.3 of Zelio Soft 2 includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware",
"product_ids": [
"CSAFPID-0014"
],
"restart_required": {
"category": "service"
},
"url": "https://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version SV2.01SP3 of EcoStruxure\u2122 OPC UA Server Expert includes a fix for this vulnerability and is available for download here:\r\nhttps://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware",
"product_ids": [
"CSAFPID-0003"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/66388-ecostruxure-opc-ua-server-expert/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version v2.5.0.1 of EcoStruxure\u2122 Machine Expert includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here:\r\nhttps://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/",
"product_ids": [
"CSAFPID-0010"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/"
},
{
"category": "vendor_fix",
"details": "Version v2.3 of EcoStruxure\u2122 Machine Expert Twin includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here:\r\nhttps://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/",
"product_ids": [
"CSAFPID-0012"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0012",
"CSAFPID-0014",
"CSAFPID-0020",
"CSAFPID-0022",
"CSAFPID-0025",
"CSAFPID-0026"
]
}
],
"title": "CVE-2024-2658"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.