ICSA-26-078-05

Vulnerability from csaf_cisa - Published: 2026-03-10 00:00 - Updated: 2026-03-19 06:00
Summary
Mitsubishi Electric CNC Series
Notes
Risk evaluation: Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products.
Critical infrastructure sectors: Critical Manufacturing
Countries/areas deployed: Worldwide
Company headquarters location: Japan
Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Conversion Disclaimer: This ICSA is a verbatim republication of Mitsubishi Electric V20250121-001#02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory.
Recommended Practices: CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.
Recommended Practices: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices: Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices: When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices: CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices: Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Vendor Fix Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW(BND-2051W000), M800VS(BND-2052W000), M80V(BND-2053W000), and M80VW(BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.
Vendor Fix Please apply the fixed version (FN or later) for Mitsubishi Electric M800W(BND-2005W000), M800S(BND-2006W000), M80(BND-2007W000), M80W(BND-2008W000), and E80(BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.
Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability.
Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability.
Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product: M800V/M80V Series Instruction Manual "16. Appendix 3 IP Address Filter Setting Function", M800/M80/E80 Series Instruction Manual "15. Appendix 2 IP Address Filter Setting Function"
Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability.
Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.
Mitigation For more information, see Mitsubishi Electric 2025-022. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf https://www.mitsubishielectric.com/psirt/vulnerab…
Acknowledgments
Mitsubishi Electric

{
  "document": {
    "acknowledgments": [
      {
        "organization": "Mitsubishi Electric",
        "summary": "reported this vulnerability to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "summary",
        "text": "Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Critical Manufacturing",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Japan",
        "title": "Company headquarters location"
      },
      {
        "category": "legal_disclaimer",
        "text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
        "title": "Legal Notice and Terms of Use"
      },
      {
        "category": "other",
        "text": "This ICSA is a verbatim republication of Mitsubishi Electric V20250121-001#02 from a direct conversion of the vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory.  Further, CISA does not endorse any commercial product or service.  Please contact CISA directly for any questions regarding this advisory.",
        "title": "Advisory Conversion Disclaimer"
      },
      {
        "category": "general",
        "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      }
    ],
    "publisher": {
      "category": "other",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-26-078-05 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-078-05.json"
      },
      {
        "category": "self",
        "summary": "Mitsubishi Electric Advisory 2025-022_en - PDF Version ",
        "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-26-078-05 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-078-05"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
      }
    ],
    "title": "Mitsubishi Electric CNC Series",
    "tracking": {
      "current_release_date": "2026-03-19T06:00:00.000000Z",
      "generator": {
        "date": "2026-03-18T17:08:10.765011Z",
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.5.0"
        }
      },
      "id": "ICSA-26-078-05",
      "initial_release_date": "2026-03-10T00:00:00.000000Z",
      "revision_history": [
        {
          "date": "2026-03-10T00:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "Initial Publication"
        },
        {
          "date": "2026-03-19T06:00:00.000000Z",
          "legacy_version": "CISA Republication",
          "number": "2",
          "summary": "Initial CISA Republication of Mitsubishi Electric V20250121-001#02 advisory"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=BB",
                "product": {
                  "name": "Mitsubishi Electric M800VW (BND-2051W000): \u003c=BB",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "M800VW (BND-2051W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=BB",
                "product": {
                  "name": "Mitsubishi Electric M800VS (BND-2052W000): \u003c=BB",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "M800VS (BND-2052W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=BB",
                "product": {
                  "name": "Mitsubishi Electric M80V (BND-2053W000): \u003c=BB",
                  "product_id": "CSAFPID-0003"
                }
              }
            ],
            "category": "product_name",
            "name": "M80V (BND-2053W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=BB",
                "product": {
                  "name": "Mitsubishi Electric M80VW (BND-2054W000): \u003c=BB",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "M80VW (BND-2054W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=FM",
                "product": {
                  "name": "Mitsubishi Electric M800W (BND-2005W000): \u003c=FM",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "M800W (BND-2005W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=FM",
                "product": {
                  "name": "Mitsubishi Electric M800S (BND-2006W000): \u003c=FM",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "M800S (BND-2006W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=FM",
                "product": {
                  "name": "Mitsubishi Electric M80 (BND-2007W000): \u003c=FM",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "M80 (BND-2007W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=FM",
                "product": {
                  "name": "Mitsubishi Electric M80W (BND-2008W000): \u003c=FM",
                  "product_id": "CSAFPID-0008"
                }
              }
            ],
            "category": "product_name",
            "name": "M80W (BND-2008W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=FM",
                "product": {
                  "name": "Mitsubishi Electric E80 (BND-2009W000): \u003c=FM",
                  "product_id": "CSAFPID-0009"
                }
              }
            ],
            "category": "product_name",
            "name": "E80 (BND-2009W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric C80 (BND-2036W000): vers:all/*",
                  "product_id": "CSAFPID-0010"
                }
              }
            ],
            "category": "product_name",
            "name": "C80 (BND-2036W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M750VW (BND-1015W002): vers:all/*",
                  "product_id": "CSAFPID-0011"
                }
              }
            ],
            "category": "product_name",
            "name": "M750VW (BND-1015W002)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M730VW (BND-1015W000): vers:all/*",
                  "product_id": "CSAFPID-0012"
                }
              }
            ],
            "category": "product_name",
            "name": " M730VW (BND-1015W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M720VW (BND-1015W000): vers:all/*",
                  "product_id": "CSAFPID-0013"
                }
              }
            ],
            "category": "product_name",
            "name": "M720VW (BND-1015W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M750VS (BND-1012W002): vers:all/*",
                  "product_id": "CSAFPID-0014"
                }
              }
            ],
            "category": "product_name",
            "name": "M750VS (BND-1012W002)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M730VS (BND-1012W000): vers:all/*",
                  "product_id": "CSAFPID-0015"
                }
              }
            ],
            "category": "product_name",
            "name": " M730VS (BND-1012W000-**)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M720VS (BND-1012W000): vers:all/*",
                  "product_id": "CSAFPID-0016"
                }
              }
            ],
            "category": "product_name",
            "name": "M720VS (BND-1012W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric M70V (BND-1018W000): vers:all/*",
                  "product_id": "CSAFPID-0017"
                }
              }
            ],
            "category": "product_name",
            "name": "M70V (BND-1018W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric E70 (BND-1022W000): vers:all/*",
                  "product_id": "CSAFPID-0018"
                }
              }
            ],
            "category": "product_name",
            "name": "E70 (BND-1022W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric NC Trainer2 (BND-1802W000): vers:all/*",
                  "product_id": "CSAFPID-0019"
                }
              }
            ],
            "category": "product_name",
            "name": "NC Trainer2 (BND-1802W000)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Mitsubishi Electric NC Trainer2 plus (BND-1803W000): vers:all/*",
                  "product_id": "CSAFPID-0020"
                }
              }
            ],
            "category": "product_name",
            "name": "NC Trainer2 plus (BND-1803W000)"
          }
        ],
        "category": "vendor",
        "name": "Mitsubishi Electric"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-2399",
      "cwe": {
        "id": "CWE-1285",
        "name": "Improper Validation of Specified Index, Position, or Offset in Input"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:Y/T:P/2026-03-10T00:00:00Z/",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007",
          "CSAFPID-0008",
          "CSAFPID-0009",
          "CSAFPID-0010",
          "CSAFPID-0011",
          "CSAFPID-0012",
          "CSAFPID-0013",
          "CSAFPID-0014",
          "CSAFPID-0015",
          "CSAFPID-0016",
          "CSAFPID-0017",
          "CSAFPID-0018",
          "CSAFPID-0019",
          "CSAFPID-0020"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-2399"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H"
        },
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/1285.html"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW(BND-2051W000), M800VS(BND-2052W000), M80V(BND-2053W000), and M80VW(BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004"
          ]
        },
        {
          "category": "vendor_fix",
          "details": " Please apply the fixed version (FN or later) for Mitsubishi Electric M800W(BND-2005W000), M800S(BND-2006W000), M80(BND-2007W000), M80W(BND-2008W000), and E80(BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative.",
          "product_ids": [
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009"
          ]
        },
        {
          "category": "mitigation",
          "details": "For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ]
        },
        {
          "category": "mitigation",
          "details": "For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ]
        },
        {
          "category": "mitigation",
          "details": "For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product: M800V/M80V Series Instruction Manual \"16. Appendix 3 IP Address Filter Setting Function\", M800/M80/E80 Series Instruction Manual \"15. Appendix 2 IP Address Filter Setting Function\"",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009"
          ]
        },
        {
          "category": "mitigation",
          "details": "For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ]
        },
        {
          "category": "mitigation",
          "details": "For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability.",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ]
        },
        {
          "category": "mitigation",
          "details": "For more information, see Mitsubishi Electric 2025-022. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf ",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ],
          "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007",
            "CSAFPID-0008",
            "CSAFPID-0009",
            "CSAFPID-0010",
            "CSAFPID-0011",
            "CSAFPID-0012",
            "CSAFPID-0013",
            "CSAFPID-0014",
            "CSAFPID-0015",
            "CSAFPID-0016",
            "CSAFPID-0017",
            "CSAFPID-0018",
            "CSAFPID-0019",
            "CSAFPID-0020"
          ]
        }
      ]
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…