rhsa-2013_0254
Vulnerability from csaf_redhat
Published
2013-02-13 09:51
Modified
2024-11-14 12:14
Summary
Red Hat Security Advisory: flash-plugin security update
Notes
Topic
An updated Adobe Flash Player package that fixes several security issues is
now available for Red Hat Enterprise Linux 5 and 6 Supplementary.
The Red Hat Security Response Team has rated this update as having critical
security impact. Common Vulnerability Scoring System (CVSS) base scores,
which give detailed severity ratings, are available for each vulnerability
from the CVE links in the References section.
Details
The flash-plugin package contains a Mozilla Firefox compatible Adobe Flash
Player web browser plug-in.
This update fixes several vulnerabilities in Adobe Flash Player. These
vulnerabilities are detailed in the Adobe Security bulletin APSB13-05,
listed in the References section. Specially-crafted SWF content could cause
flash-plugin to crash or, potentially, execute arbitrary code when a victim
loads a page containing the malicious SWF content. (CVE-2013-0638,
CVE-2013-0639, CVE-2013-0642, CVE-2013-0644, CVE-2013-0645, CVE-2013-0647,
CVE-2013-0649, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368,
CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, CVE-2013-1373, CVE-2013-1374)
A flaw in flash-plugin could allow an attacker to obtain sensitive
information if a victim were tricked into visiting a specially-crafted web
page. (CVE-2013-0637)
All users of Adobe Flash Player should install this updated package, which
upgrades Flash Player to version 11.2.202.270.
Terms of Use
This content is licensed under the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/). If you distribute this content, or a modified version of it, you must provide attribution to Red Hat Inc. and provide a link to the original.
{ "document": { "aggregate_severity": { "namespace": "https://access.redhat.com/security/updates/classification/", "text": "Critical" }, "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Copyright \u00a9 Red Hat, Inc. All rights reserved.", "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "An updated Adobe Flash Player package that fixes several security issues is\nnow available for Red Hat Enterprise Linux 5 and 6 Supplementary.\n\nThe Red Hat Security Response Team has rated this update as having critical\nsecurity impact. Common Vulnerability Scoring System (CVSS) base scores,\nwhich give detailed severity ratings, are available for each vulnerability\nfrom the CVE links in the References section.", "title": "Topic" }, { "category": "general", "text": "The flash-plugin package contains a Mozilla Firefox compatible Adobe Flash\nPlayer web browser plug-in.\n\nThis update fixes several vulnerabilities in Adobe Flash Player. These\nvulnerabilities are detailed in the Adobe Security bulletin APSB13-05,\nlisted in the References section. Specially-crafted SWF content could cause\nflash-plugin to crash or, potentially, execute arbitrary code when a victim\nloads a page containing the malicious SWF content. (CVE-2013-0638,\nCVE-2013-0639, CVE-2013-0642, CVE-2013-0644, CVE-2013-0645, CVE-2013-0647,\nCVE-2013-0649, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368,\nCVE-2013-1369, CVE-2013-1370, CVE-2013-1372, CVE-2013-1373, CVE-2013-1374)\n\nA flaw in flash-plugin could allow an attacker to obtain sensitive\ninformation if a victim were tricked into visiting a specially-crafted web\npage. (CVE-2013-0637)\n\nAll users of Adobe Flash Player should install this updated package, which\nupgrades Flash Player to version 11.2.202.270.", "title": "Details" }, { "category": "legal_disclaimer", "text": "This content is licensed under the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/). If you distribute this content, or a modified version of it, you must provide attribution to Red Hat Inc. and provide a link to the original.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "https://access.redhat.com/security/team/contact/", "issuing_authority": "Red Hat Product Security is responsible for vulnerability handling across all Red Hat products and services.", "name": "Red Hat Product Security", "namespace": "https://www.redhat.com" }, "references": [ { "category": "self", "summary": "https://access.redhat.com/errata/RHSA-2013:0254", "url": "https://access.redhat.com/errata/RHSA-2013:0254" }, { "category": "external", "summary": "https://access.redhat.com/security/updates/classification/#critical", "url": "https://access.redhat.com/security/updates/classification/#critical" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" }, { "category": "external", "summary": "910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "910571", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910571" }, { "category": "self", "summary": "Canonical URL", "url": "https://security.access.redhat.com/data/csaf/v2/advisories/2013/rhsa-2013_0254.json" } ], "title": "Red Hat Security Advisory: flash-plugin security update", "tracking": { "current_release_date": "2024-11-14T12:14:10+00:00", "generator": { "date": "2024-11-14T12:14:10+00:00", "engine": { "name": "Red Hat SDEngine", "version": "4.2.0" } }, "id": "RHSA-2013:0254", "initial_release_date": "2013-02-13T09:51:00+00:00", "revision_history": [ { "date": "2013-02-13T09:51:00+00:00", "number": "1", "summary": "Initial version" }, { "date": "2013-02-13T09:54:41+00:00", "number": "2", "summary": "Last updated version" }, { "date": "2024-11-14T12:14:10+00:00", "number": "3", "summary": "Last generated version" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Red Hat Enterprise Linux Server Supplementary (v. 5)", "product": { "name": "Red Hat Enterprise Linux Server Supplementary (v. 5)", "product_id": "5Server-Supplementary-5.9.Z", "product_identification_helper": { "cpe": "cpe:/a:redhat:rhel_extras:5::server" } } }, { "category": "product_name", "name": "Red Hat Enterprise Linux Desktop Supplementary (v. 6)", "product": { "name": "Red Hat Enterprise Linux Desktop Supplementary (v. 6)", "product_id": "6Client-Supplementary-6.3.z", "product_identification_helper": { "cpe": "cpe:/a:redhat:rhel_extras:6" } } }, { "category": "product_name", "name": "Red Hat Enterprise Linux Server Supplementary (v. 6)", "product": { "name": "Red Hat Enterprise Linux Server Supplementary (v. 6)", "product_id": "6Server-Supplementary-6.3.z", "product_identification_helper": { "cpe": "cpe:/a:redhat:rhel_extras:6" } } }, { "category": "product_name", "name": "Red Hat Enterprise Linux Workstation Supplementary (v. 6)", "product": { "name": "Red Hat Enterprise Linux Workstation Supplementary (v. 6)", "product_id": "6Workstation-Supplementary-6.3.z", "product_identification_helper": { "cpe": "cpe:/a:redhat:rhel_extras:6" } } } ], "category": "product_family", "name": "Red Hat Enterprise Linux Supplementary" }, { "branches": [ { "category": "product_version", "name": "flash-plugin-0:11.2.202.270-1.el5.i386", "product": { "name": "flash-plugin-0:11.2.202.270-1.el5.i386", "product_id": "flash-plugin-0:11.2.202.270-1.el5.i386", "product_identification_helper": { "purl": "pkg:rpm/redhat/flash-plugin@11.2.202.270-1.el5?arch=i386" } } } ], "category": "architecture", "name": "i386" }, { "branches": [ { "category": "product_version", "name": "flash-plugin-0:11.2.202.270-1.el6.i686", "product": { "name": "flash-plugin-0:11.2.202.270-1.el6.i686", "product_id": "flash-plugin-0:11.2.202.270-1.el6.i686", "product_identification_helper": { "purl": "pkg:rpm/redhat/flash-plugin@11.2.202.270-1.el6?arch=i686" } } } ], "category": "architecture", "name": "i686" } ], "category": "vendor", "name": "Red Hat" } ], "relationships": [ { "category": "default_component_of", "full_product_name": { "name": "flash-plugin-0:11.2.202.270-1.el5.i386 as a component of Red Hat Enterprise Linux Server Supplementary (v. 5)", "product_id": "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386" }, "product_reference": "flash-plugin-0:11.2.202.270-1.el5.i386", "relates_to_product_reference": "5Server-Supplementary-5.9.Z" }, { "category": "default_component_of", "full_product_name": { "name": "flash-plugin-0:11.2.202.270-1.el6.i686 as a component of Red Hat Enterprise Linux Desktop Supplementary (v. 6)", "product_id": "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" }, "product_reference": "flash-plugin-0:11.2.202.270-1.el6.i686", "relates_to_product_reference": "6Client-Supplementary-6.3.z" }, { "category": "default_component_of", "full_product_name": { "name": "flash-plugin-0:11.2.202.270-1.el6.i686 as a component of Red Hat Enterprise Linux Server Supplementary (v. 6)", "product_id": "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" }, "product_reference": "flash-plugin-0:11.2.202.270-1.el6.i686", "relates_to_product_reference": "6Server-Supplementary-6.3.z" }, { "category": "default_component_of", "full_product_name": { "name": "flash-plugin-0:11.2.202.270-1.el6.i686 as a component of Red Hat Enterprise Linux Workstation Supplementary (v. 6)", "product_id": "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" }, "product_reference": "flash-plugin-0:11.2.202.270-1.el6.i686", "relates_to_product_reference": "6Workstation-Supplementary-6.3.z" } ] }, "vulnerabilities": [ { "cve": "CVE-2013-0637", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910571" } ], "notes": [ { "category": "description", "text": "Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allow attackers to obtain sensitive information via unspecified vectors.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: information disclosure flaw (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0637" }, { "category": "external", "summary": "RHBZ#910571", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910571" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0637", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0637" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0637", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0637" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Moderate" } ], "title": "flash-plugin: information disclosure flaw (APSB13-05)" }, { "cve": "CVE-2013-0638", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allow attackers to execute arbitrary code or cause a denial of service (memory corruption) via unspecified vectors, a different vulnerability than CVE-2013-0647.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0638" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0638", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0638" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0638", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0638" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0639", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Integer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0639" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0639", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0639" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0639", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0639" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0642", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0642" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0642", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0642" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0642", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0642" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0644", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Use-after-free vulnerability in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0649 and CVE-2013-1374.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0644" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0644", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0644" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0644", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0644" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0645", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0645" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0645", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0645" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0645", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0645" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0647", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allow attackers to execute arbitrary code or cause a denial of service (memory corruption) via unspecified vectors, a different vulnerability than CVE-2013-0638.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0647" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0647", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0647" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0647", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0647" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-0649", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Use-after-free vulnerability in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0644 and CVE-2013-1374.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-0649" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-0649", "url": "https://www.cve.org/CVERecord?id=CVE-2013-0649" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-0649", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-0649" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1365", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1365" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1365", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1365" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1365", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1365" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1366", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1366" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1366", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1366" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1366", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1366" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1367", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1367" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1367", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1367" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1367", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1367" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1368", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1369, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1368" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1368", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1368" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1368", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1368" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1369", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1370, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1369" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1369", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1369" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1369", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1369" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1370", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1372, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1370" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1370", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1370" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1370", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1370" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1372", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, and CVE-2013-1373.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1372" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1372", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1372" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1372", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1372" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1373", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Buffer overflow in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0642, CVE-2013-0645, CVE-2013-1365, CVE-2013-1366, CVE-2013-1367, CVE-2013-1368, CVE-2013-1369, CVE-2013-1370, and CVE-2013-1372.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1373" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1373", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1373" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1373", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1373" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" }, { "cve": "CVE-2013-1374", "discovery_date": "2013-02-12T00:00:00+00:00", "ids": [ { "system_name": "Red Hat Bugzilla ID", "text": "910570" } ], "notes": [ { "category": "description", "text": "Use-after-free vulnerability in Adobe Flash Player before 10.3.183.63 and 11.x before 11.6.602.168 on Windows, before 10.3.183.61 and 11.x before 11.6.602.167 on Mac OS X, before 10.3.183.61 and 11.x before 11.2.202.270 on Linux, before 11.1.111.43 on Android 2.x and 3.x, and before 11.1.115.47 on Android 4.x; Adobe AIR before 3.6.0.597; and Adobe AIR SDK before 3.6.0.599 allows attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2013-0644 and CVE-2013-0649.", "title": "Vulnerability description" }, { "category": "summary", "text": "flash-plugin: multiple code execution flaws (APSB13-05)", "title": "Vulnerability summary" }, { "category": "general", "text": "The CVSS score(s) listed for this vulnerability do not reflect the associated product\u0027s status, and are included for informational purposes to better understand the severity of this vulnerability.", "title": "CVSS score applicability" } ], "product_status": { "fixed": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] }, "references": [ { "category": "self", "summary": "Canonical URL", "url": "https://access.redhat.com/security/cve/CVE-2013-1374" }, { "category": "external", "summary": "RHBZ#910570", "url": "https://bugzilla.redhat.com/show_bug.cgi?id=910570" }, { "category": "external", "summary": "https://www.cve.org/CVERecord?id=CVE-2013-1374", "url": "https://www.cve.org/CVERecord?id=CVE-2013-1374" }, { "category": "external", "summary": "https://nvd.nist.gov/vuln/detail/CVE-2013-1374", "url": "https://nvd.nist.gov/vuln/detail/CVE-2013-1374" }, { "category": "external", "summary": "http://www.adobe.com/support/security/bulletins/apsb13-05.html", "url": "http://www.adobe.com/support/security/bulletins/apsb13-05.html" } ], "release_date": "2013-02-12T00:00:00+00:00", "remediations": [ { "category": "vendor_fix", "date": "2013-02-13T09:51:00+00:00", "details": "Before applying this update, make sure all previously-released errata\nrelevant to your system have been applied.\n\nThis update is available via the Red Hat Network. Details on how to\nuse the Red Hat Network to apply this update are available at\nhttps://access.redhat.com/knowledge/articles/11258", "product_ids": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ], "restart_required": { "category": "none" }, "url": "https://access.redhat.com/errata/RHSA-2013:0254" } ], "scores": [ { "cvss_v2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "products": [ "5Server-Supplementary-5.9.Z:flash-plugin-0:11.2.202.270-1.el5.i386", "6Client-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Server-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686", "6Workstation-Supplementary-6.3.z:flash-plugin-0:11.2.202.270-1.el6.i686" ] } ], "threats": [ { "category": "impact", "details": "Critical" } ], "title": "flash-plugin: multiple code execution flaws (APSB13-05)" } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.