SA25P002

Vulnerability from csaf_abb - Published: 2025-10-07 00:30 - Updated: 2025-10-07 00:30
Summary
B&R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)

Notes

Summary
An update is available that resolves a vulnerability identified by B&Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited this vulnerability could cause the product to stop.
General security recommendations
For any installation of software-related B&R products we strongly recommend the following (non-exhaustive) list of cyber security practices: -Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and separate them from any general-purpose network (e.g. office or home networks). -Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks. -Never connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for. -Scan all data imported into your environment before use to detect potential malware infections. -Minimize network exposure for all applications and endpoints to ensure that they are not accessible from the Internet unless they are designed for such exposure and the intended use requires such. -Ensure all nodes are always up to date in terms of installed software, operating system, and firmware patches as well as anti-virus and firewall. -When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recog-nize that VPNs may have vulnerabilities and should be updated to the most current version availa-ble. Also, understand that VPNs are only as secure as the connected devices. More information on recommended practices can be found in the following documents: Defense in Depth for B&R products
Support
For additional instructions and support please contact your local B&R service organization. For contact information, see https://www.br-automation.com/en/about-us/locations/. Information about ABB’s cyber security program and capabilities can be found at www.abb.com/cybersecurity.
Notice
The information in this document is subject to change without notice, and should not be construed as a commitment by B&R. B&R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B&R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B&R or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from B&R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners.
Mitigating factors
Deactivate the vulnerable component The SDM is deactivated by default on Automation Runtime version >=6.0. For Automation Runtime versions <6.0, the SDM can be deactivated in the Automation Studio project. Please refer to Automation Help GUID 1d915d67-07f7-4034-a472-c204b5cabbfe for further guidance. Access to the System Diagnostic Manager (SDM) shall be restricted to trusted personnel through appropriate external security measures. If SDM is required solely for maintenance purposes, it should be enabled or access granted only for the minimum time necessary to perform the task. Limit accessibility B&R recommends in general to configure the HTTP protocol over TLS (HTTPS). Customers may restrict access to the webserver by configuring mutual TLS (mTLS) in the Automation Studio project (Option “Validate SSL communication partner”). Be aware that configuring mTLS would impact also other applications using the AR webserver (e.g. mapp View). Please refer to Automation Help GUID 01ced6c0-28ef-4aaa-bd05-2442b971859c to learn more about the TLS Configuration in Automation Studio. In addition, accessibility of the webserver can be limited to trusted IP addresses using the Automation Runtime host-based firewall. Please refer to Automation Help GUID 75b8994b-f97a-4e0f-8278-43c7a737e65f for details. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Purpose
B&R has a rigorous internal cyber security continuous improvement process which involves regular testing with industry leading tools and periodic assessments to identify potential product issues. Occasionally an issue is determined to be a design or coding flaw with implications that may impact product cyber security. When a potential product vulnerability is identified or reported, B&R immediately initiates our vulnerability handling process. This entails validating if the issue is in fact a product issue, identifying root causes, determining what related products may be impacted, developing a remediation, and notifying end users and governmental organizations. The resulting Cyber Security Advisory intends to notify customers of the vulnerability and provide details on which products are impacted, how to mitigate the vulnerability or explain workarounds that minimize the potential risk as much as possible. The release of a Cyber Security Advisory should not be misconstrued as an affirmation or indication of an active threat or ongoing campaign targeting the products mentioned here. If B&R is aware of any specific threats, it will be clearly mentioned in the communication. The publication of this Cyber Security Advisory is an example of B&R’s commitment to the user community in support of this critical topic. Responsible disclosure is an important element in the chain of trust we work to maintain with our many customers. The release of an Advisory provides timely information which is essential to help ensure our customers are fully informed
Frequently asked questions
What causes the vulnerability? The vulnerabilities are caused by improper resource locking. What is System Diagnostics Manager (SDM)? System Diagnostics Manager (SDM) is a webpage available over the Automation Runtime Webserver, showing key diagnostic information of the running controller What is Automation Runtime (AR)? B&R Automation Runtime is a middleware system enabling customers to run applications on B&R target systems. What might an attacker use the vulnerability to do? An attacker who successfully exploited these vulnerabilities could cause the affected system node to stop. How could an attacker exploit the vulnerability? An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above. Could the vulnerability be exploited remotely? Yes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed. When this security advisory was issued, had this vulnerability been publicly disclosed? No, B&R discovered the vulnerabilities through its own security analysis. When this security advisory was issued, had B&R received any reports that this vulnerability was being exploited? No, B&R had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "An update is available that resolves a vulnerability identified by B\u0026Rs internal security analysis in the product versions listed as affected in this advisory.\n\nAn attacker who successfully exploited this vulnerability could cause the product to stop.",
        "title": "Summary"
      },
      {
        "category": "other",
        "text": "For any installation of software-related B\u0026R products we strongly recommend the following (non-exhaustive) list of cyber security practices:\n-Isolate special purpose networks (e.g. for automation systems) and remote devices behind firewalls and separate them from any general-purpose network (e.g. office or home networks).\n-Install physical controls so no unauthorized personnel can access your devices, components, peripheral equipment, and networks.\n-Never connect programming software or computers containing programing software to any network other than the network for the devices that it is intended for.\n-Scan all data imported into your environment before use to detect potential malware infections.\n-Minimize network exposure for all applications and endpoints to ensure that they are not accessible from the Internet unless they are designed for such exposure and the intended use requires such.\n-Ensure all nodes are always up to date in terms of installed software, operating system, and firmware patches as well as anti-virus and firewall.\n-When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recog-nize that VPNs may have vulnerabilities and should be updated to the most current version availa-ble. Also, understand that VPNs are only as secure as the connected devices.\n\nMore information on recommended practices can be found in the following documents:\nDefense in Depth for B\u0026R products\n",
        "title": "General security recommendations"
      },
      {
        "category": "other",
        "text": "For additional instructions and support please contact your local B\u0026R service organization. For contact information, see https://www.br-automation.com/en/about-us/locations/.\n\nInformation about ABB\u2019s cyber security program and capabilities can be found at www.abb.com/cybersecurity.\n",
        "title": "Support"
      },
      {
        "category": "legal_disclaimer",
        "text": "The information in this document is subject to change without notice, and should not be construed as a commitment by B\u0026R.\n\nB\u0026R provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall B\u0026R or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if B\u0026R or its suppliers have been advised of the possibility of such damages.\n\nThis document and parts hereof must not be reproduced or copied without written permission from B\u0026R, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose.\n\nAll rights to registrations and trademarks reside with their respective owners.\n",
        "title": "Notice"
      },
      {
        "category": "general",
        "text": "Deactivate the vulnerable component\n\nThe SDM is deactivated by default on Automation Runtime version \u003e=6.0. For Automation Runtime versions \u003c6.0, the SDM can be deactivated in the Automation Studio project. Please refer to Automation Help GUID 1d915d67-07f7-4034-a472-c204b5cabbfe for further guidance.\n\nAccess to the System Diagnostic Manager (SDM) shall be restricted to trusted personnel through appropriate external security measures. If SDM is required solely for maintenance purposes, it should be enabled or access granted only for the minimum time necessary to perform the task.\n\nLimit accessibility\n\nB\u0026R recommends in general to configure the HTTP protocol over TLS (HTTPS). \n\nCustomers may restrict access to the webserver by configuring mutual TLS (mTLS) in the Automation Studio project (Option \u201cValidate SSL communication partner\u201d). Be aware that configuring mTLS would impact also other applications using the AR webserver (e.g. mapp View). Please refer to Automation Help GUID 01ced6c0-28ef-4aaa-bd05-2442b971859c to learn more about the TLS Configuration in Automation Studio.\n\nIn addition, accessibility of the webserver can be limited to trusted IP addresses using the Automation Runtime host-based firewall. Please refer to Automation Help GUID 75b8994b-f97a-4e0f-8278-43c7a737e65f for details.\n\nRefer to section \u201cGeneral security recommendations\u201d for further advise on how to keep your system secure.\n\n",
        "title": "Mitigating factors"
      },
      {
        "category": "other",
        "text": "B\u0026R has a rigorous internal cyber security continuous improvement process which involves regular testing with industry leading tools and periodic assessments to identify potential product issues. Occasionally an issue is determined to be a design or coding flaw with implications that may impact product cyber security.\n\nWhen a potential product vulnerability is identified or reported, B\u0026R immediately initiates our vulnerability handling process. This entails validating if the issue is in fact a product issue, identifying root causes, determining what related products may be impacted, developing a remediation, and notifying end users and governmental organizations.\n\nThe resulting Cyber Security Advisory intends to notify customers of the vulnerability and provide details on which products are impacted, how to mitigate the vulnerability or explain workarounds that minimize the potential risk as much as possible. The release of a Cyber Security Advisory should not be misconstrued as an affirmation or indication of an active threat or ongoing campaign targeting the products mentioned here. If B\u0026R is aware of any specific threats, it will be clearly mentioned in the communication.\n\nThe publication of this Cyber Security Advisory is an example of B\u0026R\u2019s commitment to the user community in support of this critical topic. Responsible disclosure is an important element in the chain of trust we work to maintain with our many customers. The release of an Advisory provides timely information which is essential to help ensure our customers are fully informed",
        "title": "Purpose"
      },
      {
        "category": "faq",
        "text": "What causes the vulnerability?\n\nThe vulnerabilities are caused by improper resource locking.\n\nWhat is System Diagnostics Manager (SDM)?\n\nSystem Diagnostics Manager (SDM) is a webpage available over the Automation Runtime Webserver, showing key diagnostic information of the running controller\n\nWhat is Automation Runtime (AR)?\n\nB\u0026R Automation Runtime is a middleware system enabling customers to run applications on B\u0026R target systems.\n\nWhat might an attacker use the vulnerability to do?\n\nAn attacker who successfully exploited these vulnerabilities could cause the affected system node to stop.\n\nHow could an attacker exploit the vulnerability?\n\nAn attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network either directly or through a wrongly configured or penetrated firewall, or that he installs malicious software on a system node or otherwise infects the network with malicious software. Recommended practices help mitigate such attacks, see section Mitigating Factors above.\n\nCould the vulnerability be exploited remotely? \nYes, an attacker who has network access to an affected system node could exploit this vulnerability. Recommended practices include that process control systems are physically protected, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a \nminimal number of ports exposed. \nWhen this security advisory was issued, had this vulnerability been publicly disclosed?\nNo, B\u0026R discovered the vulnerabilities through its own security analysis.\nWhen this security advisory was issued, had B\u0026R received any reports that this \nvulnerability was being exploited?\nNo, B\u0026R had not received any information indicating that this vulnerability had been exploited when this \nsecurity advisory was originally issued.",
        "title": "Frequently asked questions"
      }
    ],
    "publisher": {
      "category": "vendor",
      "name": "ABB PSIRT",
      "namespace": "https://global.abb/group/en/technology/cyber-security/alerts-and-notifications"
    },
    "references": [
      {
        "category": "self",
        "summary": "B\u0026R Advisory Link",
        "url": "https://www.br-automation.com/fileadmin/SA25P002-f6a69e61.pdf"
      },
      {
        "category": "self",
        "summary": "B\u0026R CYBERSECURITY ADVISORY - CSAF Version",
        "url": "https://psirt.abb.com/csaf/2025/sa25p002.json"
      }
    ],
    "title": "B\u0026R Automation Runtime DoS Vulnerability in System Diagnostics Manager (SDM)",
    "tracking": {
      "current_release_date": "2025-10-07T00:30:00.000Z",
      "generator": {
        "date": "2025-10-07T15:46:21.625Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.36"
        }
      },
      "id": "SA25P002",
      "initial_release_date": "2025-10-07T00:30:00.000Z",
      "revision_history": [
        {
          "date": "2025-10-07T00:30:00.000Z",
          "legacy_version": "A",
          "number": "1",
          "summary": "Initial version."
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c6.3",
                "product": {
                  "name": "Automation Runtime \u003c6.3",
                  "product_id": "AV1"
                }
              },
              {
                "category": "product_version",
                "name": "6.3",
                "product": {
                  "name": "Automation Runtime 6.3",
                  "product_id": "FX1"
                }
              },
              {
                "category": "product_version_range",
                "name": "\u003cQ4.93",
                "product": {
                  "name": "Automation Runtime \u003cQ4.93",
                  "product_id": "AV2"
                }
              },
              {
                "category": "product_version",
                "name": "Q4.93",
                "product": {
                  "name": "Automation Runtime Q4.93",
                  "product_id": "FX2"
                }
              }
            ],
            "category": "product_name",
            "name": "Automation Runtime"
          }
        ],
        "category": "vendor",
        "name": "B\u0026R"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-3450",
      "cwe": {
        "id": "CWE-413",
        "name": "Improper Resource Locking"
      },
      "notes": [
        {
          "category": "description",
          "text": "An Improper Resource Locking vulnerability in the SDM component of B\u0026R Automation Runtime versions before 6.3 and before Q4.93 may allow an unauthenticated network-based attacker to delete data causing denial of service conditions.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "FX1",
          "FX2"
        ],
        "known_affected": [
          "AV1",
          "AV2"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "NVD - CVE-2025-3450",
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-3450"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "The problem is corrected in Automation Runtime versions 6.3 and Q4.93.\n\nThe System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not in-tended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B\u0026R recommends applying the update at the earliest convenience.\n\nThe process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.\n",
          "product_ids": [
            "AV1",
            "AV2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "environmentalScore": 8.7,
            "environmentalSeverity": "HIGH",
            "exploitCodeMaturity": "UNPROVEN",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "remediationLevel": "OFFICIAL_FIX",
            "reportConfidence": "CONFIRMED",
            "scope": "CHANGED",
            "temporalScore": 8.7,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "AV1",
            "AV2"
          ]
        }
      ],
      "title": "CVE-2025-3450"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…