SSA-166980
Vulnerability from csaf_siemens - Published: 2026-10-26 00:00 - Updated: 2026-11-05 00:00PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
AMIS TS
Siemens / AMIS TS
|
vers:all/* |
None Available
|
|
|
blueplanet 360 NX3 M6 WM OD IISX
Siemens / blueplanet 360 NX3 M6 WM OD IISX
|
vers:all/* |
None Available
|
|
|
Energy Engage V2.0SP9
Siemens / Energy Engage V2.0SP9
|
vers:all/* |
No Fix Planned
|
|
|
Energy Engage V3.1SP1
Siemens / Energy Engage V3.1SP1
|
vers:all/* |
Vendor Fix
|
|
|
blueplanet 360 NX3 M6 WM OD IISX - S
Siemens / blueplanet 360 NX3 M6 WM OD IISX - S
|
vers:all/* |
None Available
|
|
|
Local Monitoring bt-monitoring-vm < V20261103
Siemens / Local Monitoring bt-monitoring-vm
|
vers:intdot/<20261103 |
Vendor Fix
fix
|
|
|
Spectrum Power 4 using Nagios or Zabbix
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 4 with Web Office Portal V3.0, V3.1 and V3.2
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 4 with HISViews V1.0
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 7 using IHM (NagiosXI)
Siemens / Spectrum Power 7
|
vers:all/* |
Vendor Fix
|
|
|
Spectrum Power TG which are based on Microsoft Windows using the WebConsole and WebQuery components
Siemens / Spectrum Power TG
|
vers:all/* |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Connect X200
Siemens / Connect X200
|
vers:all/* | ||
|
Connect X300
Siemens / Connect X300
|
vers:all/* | ||
|
Connect X500
Siemens / Connect X500
|
vers:all/* | ||
|
cRSP
Siemens / cRSP
|
vers:all/* | ||
|
Depotfinity
Siemens / Depotfinity
|
vers:all/* | ||
|
Desigo CC
Siemens / Desigo CC
|
vers:all/* | ||
|
Desigo DXR2
Siemens / Desigo DXR2
|
vers:all/* | ||
|
Desigo DXR3
Siemens / Desigo DXR3
|
vers:all/* | ||
|
Desigo Optic
Siemens / Desigo Optic
|
vers:all/* | ||
|
Desigo PXC3
Siemens / Desigo PXC3
|
vers:all/* | ||
|
Desigo PXC4
Siemens / Desigo PXC4
|
vers:all/* | ||
|
Desigo PXC5
Siemens / Desigo PXC5
|
vers:all/* | ||
|
Desigo PXC7
Siemens / Desigo PXC7
|
vers:all/* | ||
|
Energy Management System
Siemens / Energy Management System
|
vers:all/* | ||
|
Enlighted RTLS
Siemens / Enlighted RTLS
|
vers:all/* | ||
|
Enlighted Space
Siemens / Enlighted Space
|
vers:all/* | ||
|
Heliox Flex Pro
Siemens / Heliox Flex Pro
|
vers:all/* | ||
|
Heliox H60
Siemens / Heliox H60
|
vers:all/* | ||
|
Heliox Rapid
Siemens / Heliox Rapid
|
vers:all/* | ||
|
Navigator E&S
Siemens / Navigator E&S
|
vers:all/* | ||
|
Novigo VANSYS
Siemens / Novigo VANSYS
|
vers:all/* | ||
|
Novigo VANSYS core
Siemens / Novigo VANSYS core
|
vers:all/* | ||
|
PACE-Design
Siemens / PACE-Design
|
vers:all/* | ||
|
Sicharge D
Siemens / Sicharge D
|
vers:all/* | ||
|
Sicharge D Configuration Backend
Siemens / Sicharge D Configuration Backend
|
vers:all/* | ||
|
SICHARGE FLEX
Siemens / SICHARGE FLEX
|
vers:all/* | ||
|
SICHARGE UC
Siemens / SICHARGE UC
|
vers:all/* | ||
|
Building X
Siemens / Building X
|
vers:all/* | ||
|
Sifinity Control
Siemens / Sifinity Control
|
vers:all/* | ||
|
Sifinity Go
Siemens / Sifinity Go
|
vers:all/* | ||
|
Sifinity Setup
Siemens / Sifinity Setup
|
vers:all/* | ||
|
Sinteso FS20 EN
Siemens / Sinteso FS20 EN
|
vers:all/* | ||
|
SiPass integrated
Siemens / SiPass integrated
|
vers:all/* | ||
|
SIPORT
Siemens / SIPORT
|
vers:all/* | ||
|
Siveillance Control
Siemens / Siveillance Control
|
vers:all/* | ||
|
Siveillance Control Pro
Siemens / Siveillance Control Pro
|
vers:all/* | ||
|
Siveillance Intrusion
Siemens / Siveillance Intrusion
|
vers:all/* | ||
|
Siveillance Video
Siemens / Siveillance Video
|
vers:all/* | ||
|
Call stations
Siemens / Call stations
|
vers:all/* | ||
|
Verischarge
Siemens / Verischarge
|
vers:all/* | ||
|
VersiCloudHeliox Dual Port 60kW
Siemens / VersiCloudHeliox Dual Port 60kW
|
vers:all/* | ||
|
Voice alarm panels
Siemens / Voice alarm panels
|
vers:all/* | ||
|
Voice alarm systems and audio matrices
Siemens / Voice alarm systems and audio matrices
|
vers:all/* | ||
|
Chargesight
Siemens / Chargesight
|
vers:all/* | ||
|
Workplace Experience
Siemens / Workplace Experience
|
vers:all/* | ||
|
Climatix Cloud IC
Siemens / Climatix Cloud IC
|
vers:all/* | ||
|
Climatix Devices
Siemens / Climatix Devices
|
vers:all/* | ||
|
Connect Insights
Siemens / Connect Insights
|
vers:all/* |
PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
AMIS TS
Siemens / AMIS TS
|
vers:all/* |
None Available
|
|
|
blueplanet 360 NX3 M6 WM OD IISX
Siemens / blueplanet 360 NX3 M6 WM OD IISX
|
vers:all/* |
None Available
|
|
|
Energy Engage V2.0SP9
Siemens / Energy Engage V2.0SP9
|
vers:all/* |
No Fix Planned
|
|
|
Energy Engage V3.1SP1
Siemens / Energy Engage V3.1SP1
|
vers:all/* |
Vendor Fix
|
|
|
blueplanet 360 NX3 M6 WM OD IISX - S
Siemens / blueplanet 360 NX3 M6 WM OD IISX - S
|
vers:all/* |
None Available
|
|
|
Local Monitoring bt-monitoring-vm < V20261103
Siemens / Local Monitoring bt-monitoring-vm
|
vers:intdot/<20261103 |
Vendor Fix
fix
|
|
|
Spectrum Power 3 using IHM (NagiosXI) running on Red Hat Enterprise Linux version (RHEL) 7
Siemens / Spectrum Power 3
|
vers:all/* |
Vendor Fix
|
|
|
Spectrum Power 4 using Nagios or Zabbix
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 4 with Web Office Portal V3.0, V3.1 and V3.2
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 4 with HISViews V1.0
Siemens / Spectrum Power 4
|
vers:all/* |
None Available
|
|
|
Spectrum Power 7 using IHM (NagiosXI)
Siemens / Spectrum Power 7
|
vers:all/* |
Vendor Fix
|
|
|
Spectrum Power TG which are based on Microsoft Windows using the WebConsole and WebQuery components
Siemens / Spectrum Power TG
|
vers:all/* |
Vendor Fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "On October 21, 2026, the PHP project and security researchers disclosed two critical, unauthenticated remote code execution vulnerabilities in the core PHP language runtime known as \"php2shell\" (tracked as CVE-2026-109618 and CVE-2026-109619). This advisory covers the status of impact of various Siemens software products.\n\nAs a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines, and to follow the recommendations in the product manuals.\n\nSiemens is actively monitoring the situation and assessing the implications of these vulnerabilities on our portfolio. Because this evaluation is ongoing, our findings are subject to change as new technical details and vendor updates emerge. We will publish updated findings, guidance, and remediation recommendations as soon as they become available.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\nhttps://www.siemens.com/gridsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-166980: PHP2Shell Vulnerabilities in Siemens Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166980.html"
},
{
"category": "self",
"summary": "SSA-166980: PHP2Shell Vulnerabilities in Siemens Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-166980.json"
}
],
"title": "SSA-166980: PHP2Shell Vulnerabilities in Siemens Products",
"tracking": {
"current_release_date": "2026-11-05T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-166980",
"initial_release_date": "2026-10-26T00:00:00.000Z",
"revision_history": [
{
"date": "2026-10-26T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-10-27T00:00:00.000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated the Known not affected list"
},
{
"date": "2026-10-29T00:00:00.000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added AMIS TS, Energy Engage V2.0SP9, Energy Engage V3.1SP1, Spectrum Power 3, Spectrum Power 4, Spectrum Power 7 and Spectrum Power TG to Affected Products and updated the list of known not affected"
},
{
"date": "2026-11-05T00:00:00.000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Updated Known Not Affected and Known Affected Products list"
}
],
"status": "interim",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "AMIS TS",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "AMIS TS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet 360 NX3 M6 WM OD IISX",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "blueplanet 360 NX3 M6 WM OD IISX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet 360 NX3 M6 WM OD IISX - S",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "blueplanet 360 NX3 M6 WM OD IISX - S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Building X",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Building X"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Call stations",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Call stations"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Chargesight",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Chargesight"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Climatix Cloud IC",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Climatix Cloud IC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Climatix Devices",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Climatix Devices"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Connect Insights",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Connect Insights"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Connect X200",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "Connect X200"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Connect X300",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "Connect X300"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Connect X500",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "Connect X500"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "cRSP",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "cRSP"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Depotfinity",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "Depotfinity"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "Desigo CC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo DXR2",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "Desigo DXR2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo DXR3",
"product_id": "17"
}
}
],
"category": "product_name",
"name": "Desigo DXR3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo Optic",
"product_id": "18"
}
}
],
"category": "product_name",
"name": "Desigo Optic"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo PXC3",
"product_id": "19"
}
}
],
"category": "product_name",
"name": "Desigo PXC3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo PXC4",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "Desigo PXC4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo PXC5",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "Desigo PXC5"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo PXC7",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "Desigo PXC7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Energy Engage V2.0SP9",
"product_id": "23"
}
}
],
"category": "product_name",
"name": "Energy Engage V2.0SP9"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Energy Engage V3.1SP1",
"product_id": "24"
}
}
],
"category": "product_name",
"name": "Energy Engage V3.1SP1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Energy Management System",
"product_id": "25"
}
}
],
"category": "product_name",
"name": "Energy Management System"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Enlighted RTLS",
"product_id": "26"
}
}
],
"category": "product_name",
"name": "Enlighted RTLS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Enlighted Space",
"product_id": "27"
}
}
],
"category": "product_name",
"name": "Enlighted Space"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Heliox Flex Pro",
"product_id": "28"
}
}
],
"category": "product_name",
"name": "Heliox Flex Pro"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Heliox H60",
"product_id": "29"
}
}
],
"category": "product_name",
"name": "Heliox H60"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Heliox Rapid",
"product_id": "30"
}
}
],
"category": "product_name",
"name": "Heliox Rapid"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c20261103",
"product": {
"name": "Local Monitoring bt-monitoring-vm \u003c V20261103",
"product_id": "31"
}
}
],
"category": "product_name",
"name": "Local Monitoring bt-monitoring-vm"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Navigator E\u0026S",
"product_id": "32"
}
}
],
"category": "product_name",
"name": "Navigator E\u0026S"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Novigo VANSYS",
"product_id": "33"
}
}
],
"category": "product_name",
"name": "Novigo VANSYS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Novigo VANSYS core",
"product_id": "34"
}
}
],
"category": "product_name",
"name": "Novigo VANSYS core"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "PACE-Design",
"product_id": "35"
}
}
],
"category": "product_name",
"name": "PACE-Design"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sicharge D",
"product_id": "36"
}
}
],
"category": "product_name",
"name": "Sicharge D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sicharge D Configuration Backend",
"product_id": "37"
}
}
],
"category": "product_name",
"name": "Sicharge D Configuration Backend"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICHARGE FLEX",
"product_id": "38"
}
}
],
"category": "product_name",
"name": "SICHARGE FLEX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICHARGE UC",
"product_id": "39"
}
}
],
"category": "product_name",
"name": "SICHARGE UC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sifinity Control",
"product_id": "40"
}
}
],
"category": "product_name",
"name": "Sifinity Control"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sifinity Go",
"product_id": "41"
}
}
],
"category": "product_name",
"name": "Sifinity Go"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sifinity Setup",
"product_id": "42"
}
}
],
"category": "product_name",
"name": "Sifinity Setup"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sinteso FS20 EN",
"product_id": "43"
}
}
],
"category": "product_name",
"name": "Sinteso FS20 EN"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SiPass integrated",
"product_id": "44"
}
}
],
"category": "product_name",
"name": "SiPass integrated"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPORT",
"product_id": "45"
}
}
],
"category": "product_name",
"name": "SIPORT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siveillance Control",
"product_id": "46"
}
}
],
"category": "product_name",
"name": "Siveillance Control"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siveillance Control Pro",
"product_id": "47"
}
}
],
"category": "product_name",
"name": "Siveillance Control Pro"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siveillance Intrusion",
"product_id": "48"
}
}
],
"category": "product_name",
"name": "Siveillance Intrusion"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siveillance Video",
"product_id": "49"
}
}
],
"category": "product_name",
"name": "Siveillance Video"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power 3 using IHM (NagiosXI) running on Red Hat Enterprise Linux version (RHEL) 7",
"product_id": "50"
}
}
],
"category": "product_name",
"name": "Spectrum Power 3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power 4 using Nagios or Zabbix",
"product_id": "51"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power 4 with Web Office Portal V3.0, V3.1 and V3.2",
"product_id": "52"
}
},
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power 4 with HISViews V1.0",
"product_id": "53"
}
}
],
"category": "product_name",
"name": "Spectrum Power 4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power 7 using IHM (NagiosXI)",
"product_id": "54"
}
}
],
"category": "product_name",
"name": "Spectrum Power 7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Spectrum Power TG which are based on Microsoft Windows using the WebConsole and WebQuery components",
"product_id": "55"
}
}
],
"category": "product_name",
"name": "Spectrum Power TG"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Verischarge",
"product_id": "56"
}
}
],
"category": "product_name",
"name": "Verischarge"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "VersiCloudHeliox Dual Port 60kW",
"product_id": "57"
}
}
],
"category": "product_name",
"name": "VersiCloudHeliox Dual Port 60kW"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Voice alarm panels",
"product_id": "58"
}
}
],
"category": "product_name",
"name": "Voice alarm panels"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Voice alarm systems and audio matrices",
"product_id": "59"
}
}
],
"category": "product_name",
"name": "Voice alarm systems and audio matrices"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Workplace Experience",
"product_id": "60"
}
}
],
"category": "product_name",
"name": "Workplace Experience"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-109618",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"48",
"45",
"28",
"32",
"38",
"39",
"30",
"49",
"57",
"14",
"34",
"56",
"59",
"20",
"35",
"15",
"5",
"21",
"60",
"8",
"22",
"29",
"47",
"26",
"11",
"36",
"18",
"37",
"44",
"25",
"10",
"41",
"27",
"12",
"43",
"9",
"19",
"7",
"46",
"6",
"58",
"13",
"4",
"33",
"40",
"42",
"16",
"17"
]
}
],
"notes": [
{
"category": "description",
"text": "PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE).",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"23",
"24",
"3",
"31",
"51",
"52",
"53",
"54",
"55"
],
"known_not_affected": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"25",
"26",
"27",
"28",
"29",
"30",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"4",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"5",
"56",
"57",
"58",
"59",
"6",
"60",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"23"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"1",
"2",
"3",
"51",
"52",
"53"
]
},
{
"category": "vendor_fix",
"details": "Update to V20261103 or later version",
"product_ids": [
"31"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/110007932/"
},
{
"category": "vendor_fix",
"details": "Red Hat released a PHP security patch for RHEL 8 and 9",
"product_ids": [
"54"
]
},
{
"category": "vendor_fix",
"details": "Upgrade PHP version to V8.5.12",
"product_ids": [
"55"
]
},
{
"category": "vendor_fix",
"details": "Upgrade PHP version to V8.1.34 release 6",
"product_ids": [
"24"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"23",
"24",
"3",
"31",
"51",
"52",
"53",
"54",
"55"
]
}
],
"threats": [
{
"category": "impact",
"details": "PHP is not present in this product",
"product_ids": [
"48",
"45",
"28",
"32",
"38",
"39",
"30",
"49",
"57",
"14",
"34",
"56",
"59",
"20",
"35",
"15",
"5",
"21",
"60",
"8",
"22",
"29",
"47",
"26",
"11",
"36",
"18",
"37",
"44",
"25",
"10",
"41",
"27",
"12",
"43",
"9",
"19",
"7",
"46",
"6",
"58",
"13",
"4",
"33",
"40",
"42",
"16",
"17"
]
}
],
"title": "CVE-2026-109618"
},
{
"cve": "CVE-2026-109619",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"48",
"45",
"28",
"32",
"38",
"39",
"30",
"49",
"57",
"14",
"34",
"56",
"59",
"20",
"35",
"15",
"5",
"21",
"60",
"8",
"22",
"29",
"47",
"26",
"11",
"36",
"18",
"37",
"44",
"25",
"10",
"41",
"27",
"12",
"43",
"9",
"19",
"7",
"46",
"6",
"58",
"13",
"4",
"33",
"40",
"42",
"16",
"17"
]
}
],
"notes": [
{
"category": "description",
"text": "PHP has various global state that temporarily points into request memory. In some scenarios, global state may not be correctly reset, or may be repopulated after being reset. The global state may then refer to request memory even after it has been freed. Subsequent requests may read or branch on this stale state before it is fully initialized. Multiple strategies can trigger this condition and produce remote code execution (RCE).",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"23",
"24",
"3",
"31",
"50",
"51",
"52",
"53",
"54",
"55"
],
"known_not_affected": [
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"25",
"26",
"27",
"28",
"29",
"30",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"4",
"40",
"41",
"42",
"43",
"44",
"45",
"46",
"47",
"48",
"49",
"5",
"56",
"57",
"58",
"59",
"6",
"60",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"23"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"1",
"2",
"3",
"51",
"52",
"53"
]
},
{
"category": "vendor_fix",
"details": "Update to V20261103 or later version",
"product_ids": [
"31"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/110007932/"
},
{
"category": "vendor_fix",
"details": "Red Hat released a PHP security patch for RHEL 8 and 9",
"product_ids": [
"54"
]
},
{
"category": "vendor_fix",
"details": "Red Hat released a PHP security patch for RHEL 7",
"product_ids": [
"50"
]
},
{
"category": "vendor_fix",
"details": "Upgrade PHP version to V8.5.12",
"product_ids": [
"55"
]
},
{
"category": "vendor_fix",
"details": "Upgrade PHP version to V8.1.34 release 6",
"product_ids": [
"24"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"23",
"24",
"3",
"31",
"50",
"51",
"52",
"53",
"54",
"55"
]
}
],
"threats": [
{
"category": "impact",
"details": "PHP is not present in this product",
"product_ids": [
"48",
"45",
"28",
"32",
"38",
"39",
"30",
"49",
"57",
"14",
"34",
"56",
"59",
"20",
"35",
"15",
"5",
"21",
"60",
"8",
"22",
"29",
"47",
"26",
"11",
"36",
"18",
"37",
"44",
"25",
"10",
"41",
"27",
"12",
"43",
"9",
"19",
"7",
"46",
"6",
"58",
"13",
"4",
"33",
"40",
"42",
"16",
"17"
]
}
],
"title": "CVE-2026-109619"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.