SSA-367714

Vulnerability from csaf_siemens - Published: 2025-05-23 00:00 - Updated: 2025-10-14 00:00
Summary
SSA-367714: Improper Integrity Check of Firmware Updates in SiPass integrated AC5102 / ACC-G2 and ACC-AP

Notes

Summary
SiPass integrated ACC (Advanced Central Controller) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SiPass integrated ACC (Advanced Central Controller) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device.\n\nSiemens recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-367714: Improper Integrity Check of Firmware Updates in SiPass integrated AC5102 / ACC-G2 and ACC-AP - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-367714.html"
      },
      {
        "category": "self",
        "summary": "SSA-367714: Improper Integrity Check of Firmware Updates in SiPass integrated AC5102 / ACC-G2 and ACC-AP - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-367714.json"
      }
    ],
    "title": "SSA-367714: Improper Integrity Check of Firmware Updates in SiPass integrated AC5102 / ACC-G2 and ACC-AP",
    "tracking": {
      "current_release_date": "2025-10-14T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-367714",
      "initial_release_date": "2025-05-23T00:00:00Z",
      "revision_history": [
        {
          "date": "2025-05-23T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2025-10-14T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Clarified that currently no fix is planned for affected devices"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SiPass integrated AC5102 (ACC-G2)",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SiPass integrated AC5102 (ACC-G2)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SiPass integrated ACC-AP",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SiPass integrated ACC-AP"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-31807",
      "cwe": {
        "id": "CWE-347",
        "name": "Improper Verification of Cryptographic Signature"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware \"on the fly\".",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Enable TLS for communication between servers and affected devices; this mitigates the risk of on-path attackers that intercept and modify the firmware during transmission",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2022-31807"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…