Vulnerability from csaf_siemens - Published: 2025-02-11 00:00 - Updated: 2025-04-08 00:00Summary
SSA-369369: Weak Registry Permission Vulnerability in SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor
Notes
Summary
SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor contain a weak registry permission vulnerability that could allow an authenticated attacker to perform privilege escalation or bypass security measures.
Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor contain a weak registry permission vulnerability that could allow an authenticated attacker to perform privilege escalation or bypass security measures.\n\nSiemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-369369: Weak Registry Permission Vulnerability in SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-369369.html"
},
{
"category": "self",
"summary": "SSA-369369: Weak Registry Permission Vulnerability in SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-369369.json"
}
],
"title": "SSA-369369: Weak Registry Permission Vulnerability in SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor",
"tracking": {
"current_release_date": "2025-04-08T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-369369",
"initial_release_date": "2025-02-11T00:00:00Z",
"revision_history": [
{
"date": "2025-02-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-04-08T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added Sixtus Leonhardsberger to Acknowledgment"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC IPC DiagBase",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC DiagBase"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC IPC DiagMonitor",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC DiagMonitor"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-23403",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Remove the user privilege by modifying the registry manually or running a script. For more information refer the FAQ section at: \nhttps://support.industry.siemens.com/cs/document/109978178",
"product_ids": [
"1",
"2"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.0,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2025-23403"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…