SSA-384224

Vulnerability from csaf_siemens - Published: 2022-10-11 00:00 - Updated: 2022-10-11 00:00
Summary
SSA-384224: Denial of Service Vulnerability in SIMATIC HMI Panels

Notes

Summary
Several SIMATIC HMI Panels are affected by a vulnerability that could allow an attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets. Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Several SIMATIC HMI Panels are affected by a vulnerability that could allow an attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: \nhttps://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-384224: Denial of Service Vulnerability in SIMATIC HMI Panels - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-384224.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-384224: Denial of Service Vulnerability in SIMATIC HMI Panels - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-384224.txt"
      },
      {
        "category": "self",
        "summary": "SSA-384224: Denial of Service Vulnerability in SIMATIC HMI Panels - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-384224.json"
      }
    ],
    "title": "SSA-384224: Denial of Service Vulnerability in SIMATIC HMI Panels",
    "tracking": {
      "current_release_date": "2022-10-11T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-384224",
      "initial_release_date": "2022-10-11T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-10-11T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 4",
                "product": {
                  "name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 4",
                "product": {
                  "name": "SIMATIC HMI KTP Mobile Panels",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP Mobile Panels"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIMATIC HMI KTP1200 Basic (6AV2123-2MB03-0AX0)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AV2123-2MB03-0AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP1200 Basic (6AV2123-2MB03-0AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIMATIC HMI KTP400 Basic (6AV2123-2DB03-0AX0)",
                  "product_id": "4",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AV2123-2DB03-0AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP400 Basic (6AV2123-2DB03-0AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIMATIC HMI KTP700 Basic (6AV2123-2GB03-0AX0)",
                  "product_id": "5",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AV2123-2GB03-0AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP700 Basic (6AV2123-2GB03-0AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIMATIC HMI KTP900 Basic (6AV2123-2JB03-0AX0)",
                  "product_id": "6",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AV2123-2JB03-0AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP900 Basic (6AV2123-2JB03-0AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIPLUS HMI KTP1200 BASIC (6AG1123-2MB03-2AX0)",
                  "product_id": "7",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AG1123-2MB03-2AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIPLUS HMI KTP1200 BASIC (6AG1123-2MB03-2AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIPLUS HMI KTP400 BASIC (6AG1123-2DB03-2AX0)",
                  "product_id": "8",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AG1123-2DB03-2AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIPLUS HMI KTP400 BASIC (6AG1123-2DB03-2AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIPLUS HMI KTP700 BASIC (6AG1123-2GB03-2AX0)",
                  "product_id": "9",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AG1123-2GB03-2AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIPLUS HMI KTP700 BASIC (6AG1123-2GB03-2AX0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V17 Update 5",
                "product": {
                  "name": "SIPLUS HMI KTP900 BASIC (6AG1123-2JB03-2AX0)",
                  "product_id": "10",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AG1123-2JB03-2AX0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SIPLUS HMI KTP900 BASIC (6AG1123-2JB03-2AX0)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-40227",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly validate input sent to certain services over TCP. This could allow an unauthenticated remote attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V17 Update 4 or later version",
          "product_ids": [
            "1",
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109746530/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V17 Update 5 or later version",
          "product_ids": [
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109746530/"
        },
        {
          "category": "workaround",
          "details": "Restrict access to port 5001/tcp and 5002/tcp to trusted IP addresses only",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10"
          ]
        }
      ],
      "title": "CVE-2022-40227"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…