ssa-434032
Vulnerability from csaf_siemens
Published
2019-11-12 00:00
Modified
2024-02-13 00:00
Summary
SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS

Notes

Summary
The DHCP implementation of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability that could allow an attacker to change the IP address of an affected device to an invalid value. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "The DHCP implementation of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) contains a vulnerability that could allow an attacker to change the IP address of an affected device to an invalid value.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
      },
      {
        "category": "self",
        "summary": "SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-434032.json"
      },
      {
        "category": "self",
        "summary": "SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-434032.txt"
      }
    ],
    "title": "SSA-434032: Input Validation Vulnerability in the DHCP Client of Nucleus RTOS",
    "tracking": {
      "current_release_date": "2024-02-13T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-434032",
      "initial_release_date": "2019-11-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2019-11-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2024-02-13T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Consolidated list of products; renamed Capital VSTAR to Capital Embedded AR Classic; added fix and mitigation for Capital Embedded AR Classic; added CVSSv4.0 vector and score"
        }
      ],
      "status": "interim",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Capital Embedded AR Classic 431-422",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Capital Embedded AR Classic 431-422"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV2303",
                "product": {
                  "name": "Capital Embedded AR Classic R20-11",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Capital Embedded AR Classic R20-11"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Nucleus NET",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "Nucleus NET"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003cV2017.02.3",
                "product": {
                  "name": "Nucleus ReadyStart V3",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "Nucleus ReadyStart V3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Nucleus Source Code",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "Nucleus Source Code"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2019-13939",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Avoid using DHCP Client of Nucleus NET",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5"
          ]
        },
        {
          "category": "mitigation",
          "details": "Contact customer support or your local Nucleus Sales team for mitigation advice",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "mitigation",
          "details": "Disable DHCP client functionality, if feature not used, by deselecting the TcpIpIpV4General/TcpIpDhcpClientEnabled Pre-Compile configuration option",
          "product_ids": [
            "1",
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Update to the latest version of Nucleus ReadyStart V3 or V4",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2017.02.3 or later version",
          "product_ids": [
            "4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2303 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Contact customer support to receive patch and update information",
          "product_ids": [
            "5"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5"
          ]
        }
      ],
      "title": "CVE-2019-13939"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.