SSA-478893

Vulnerability from csaf_siemens - Published: 2020-12-08 00:00 - Updated: 2021-05-11 00:00
Summary
SSA-478893: TightVNC Vulnerabilities in Industrial Products (Revoked)

Notes

Summary
Multiple TightVNC (V1.x) vulnerabilities could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has previously released this advisory containing a set of products that were considered to be affected. Through Siemens' continuous investigation processes it was identified that all products previously advised are not affected by any vulnerability listed in this advisory.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Multiple TightVNC (V1.x) vulnerabilities could allow remote code execution and Denial-of-Service attacks under certain conditions.\n\nSiemens has previously released this advisory containing a set of products that were considered to be affected. Through Siemens\u0027 continuous investigation processes it was identified that all products previously advised are not affected by any vulnerability listed in this advisory.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-478893: TightVNC Vulnerabilities in Industrial Products (Revoked) - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478893.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-478893: TightVNC Vulnerabilities in Industrial Products (Revoked) - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-478893.txt"
      },
      {
        "category": "self",
        "summary": "SSA-478893: TightVNC Vulnerabilities in Industrial Products (Revoked) - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-478893.json"
      }
    ],
    "title": "SSA-478893: TightVNC Vulnerabilities in Industrial Products (Revoked)",
    "tracking": {
      "current_release_date": "2021-05-11T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-478893",
      "initial_release_date": "2020-12-08T00:00:00Z",
      "revision_history": [
        {
          "date": "2020-12-08T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2021-05-11T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Errata - Revoked advisory"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC1500 V3.1",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC1500 V3.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC1500 V3.1 PRO",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC1500 V3.1 PRO"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC1900 V3.1",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC1900 V3.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC1900 V3.1 PRO",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC1900 V3.1 PRO"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC2200 V3.1",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC2200 V3.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC ITC2200 V3.1 PRO",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC ITC2200 V3.1 PRO"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC WinCC Runtime Advanced",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Advanced"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "No version",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2019-8287",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "TightVNC code version 1.3.10 contains global buffer overflow in HandleCoRREBBP macro function, which can potentially result in code execution. This attack appear to be exploitable via network connectivity.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11"
        ]
      },
      "references": [
        {
          "summary": "CVE-2019-8287 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-8287.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "This product is not affected by any vulnerability listed in this advisory",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "title": "CVE-2019-8287"
    },
    {
      "cve": "CVE-2019-15678",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "TightVNC code version 1.3.10 contains heap buffer overflow in rfbServerCutText handler, which can potentially result in code execution. This attack appear to be exploitable via network connectivity.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11"
        ]
      },
      "references": [
        {
          "summary": "CVE-2019-15678 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15678.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "This product is not affected by any vulnerability listed in this advisory",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "title": "CVE-2019-15678"
    },
    {
      "cve": "CVE-2019-15679",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "TightVNC code version 1.3.10 contains heap buffer overflow in InitialiseRFBConnection function, which can potentially result in code execution. This attack appear to be exploitable via network connectivity.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11"
        ]
      },
      "references": [
        {
          "summary": "CVE-2019-15679 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15679.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "This product is not affected by any vulnerability listed in this advisory",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "title": "CVE-2019-15679"
    },
    {
      "cve": "CVE-2019-15680",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "TightVNC code version 1.3.10 contains null pointer dereference in HandleZlibBPP function, which could result in a Denial-of-Service (DoS). This attack appear to be exploitable via network connectivity.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11"
        ]
      },
      "references": [
        {
          "summary": "CVE-2019-15680 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-15680.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "This product is not affected by any vulnerability listed in this advisory",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11"
          ]
        }
      ],
      "title": "CVE-2019-15680"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…