SSA-514895
Vulnerability from csaf_siemens - Published: 2025-11-11 00:00 - Updated: 2025-11-11 00:00Summary
SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0
Notes
Summary: Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions.
Siemens has released a new version for Altair Grid Engine and recommends to update to the latest version.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
5.5 (Medium)
Mitigation
For clusters not using the UGERest API/daemon remove the setuid-root bit from the binaries for all architectures: chmod u-s $SGE_ROOT/utilbin/<arch>/authuser.
Vendor Fix
Update to V2026.0.0 or later version
https://altairone.com/Marketplace
7.8 (High)
Mitigation
For non Windows clusters remove the setuid-root bit from the "sgepasswd" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/<arch>/sgepasswd.
Vendor Fix
Update to V2026.0.0 or later version
https://altairone.com/Marketplace
References
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Altair Grid Engine contain multiple vulnerabilities that could allow an attacker to escalate privileges and execute arbitrary code with superuser permissions.\nSiemens has released a new version for Altair Grid Engine and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-514895.html"
},
{
"category": "self",
"summary": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-514895.json"
}
],
"title": "SSA-514895: Multiple Vulnerabilities in Altair Grid Engine V2025.1.0",
"tracking": {
"current_release_date": "2025-11-11T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-514895",
"initial_release_date": "2025-11-11T00:00:00Z",
"revision_history": [
{
"date": "2025-11-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2026.0.0",
"product": {
"name": "Altair Grid Engine",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Altair Grid Engine"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-40760",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests.\r\nThis could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For clusters not using the UGERest API/daemon remove the setuid-root bit from the binaries for all architectures: chmod u-s $SGE_ROOT/utilbin/\u0026lt;arch\u0026gt;/authuser.",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V2026.0.0 or later version",
"product_ids": [
"1"
],
"url": "https://altairone.com/Marketplace"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40760"
},
{
"cve": "CVE-2025-40763",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution.\r\nThis could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "For non Windows clusters remove the setuid-root bit from the \"sgepasswd\" binary for all installed architectures: chmod u-s $SGE_ROOT/bin/\u0026lt;arch\u0026gt;/sgepasswd.",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V2026.0.0 or later version",
"product_ids": [
"1"
],
"url": "https://altairone.com/Marketplace"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40763"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…