SSA-759952
Vulnerability from csaf_siemens - Published: 2022-08-09 00:00 - Updated: 2022-08-09 00:00Summary
SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter
Notes
Summary
Teamcenter is affected by two security vulnerabilities in the File
Service Cache service that could lead to command injection and denial
of service issues. Siemens has released updates for the affected
products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect
network access to devices with appropriate mechanisms. In order to
operate the devices in a protected IT environment, Siemens recommends
to configure the environment according to Siemens' operational
guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-
security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found
at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter is affected by two security vulnerabilities in the File\nService Cache service that could lead to command injection and denial\nof service issues. Siemens has released updates for the affected\nproducts and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
},
{
"category": "self",
"summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-759952.txt"
},
{
"category": "self",
"summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-759952.json"
}
],
"title": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter",
"tracking": {
"current_release_date": "2022-08-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-759952",
"initial_release_date": "2022-08-09T00:00:00Z",
"revision_history": [
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V12.4.0.15",
"product": {
"name": "Teamcenter V12.4",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Teamcenter V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.0.0.10",
"product": {
"name": "Teamcenter V13.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.1.0.10",
"product": {
"name": "Teamcenter V13.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.2.0.9",
"product": {
"name": "Teamcenter V13.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.3.0.5",
"product": {
"name": "Teamcenter V13.3",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14.0.0.2",
"product": {
"name": "Teamcenter V14.0",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-34660",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "mitigation",
"details": "Limit access to port 4544/tcp to specific IP addresses, e.g. with a\nfirewall",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.15 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.10 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.10 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.9 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.5 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2022-34660"
},
{
"cve": "CVE-2022-34661",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "File Server Cache service in Teamcenter is vulnerable to denial of service by entering infinite loops and using up CPU cycles. This could allow an attacker to cause denial of service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "mitigation",
"details": "Limit access to port 4544/tcp to specific IP addresses, e.g. with a\nfirewall",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.15 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.10 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.10 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.9 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.5 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2022-34661"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…