SSA-789162
Vulnerability from csaf_siemens - Published: 2022-05-10 00:00 - Updated: 2022-08-09 00:00Summary
SSA-789162: Vulnerabilities in Teamcenter
Notes
Summary
Teamcenter is affected by XML External Entity Injection (XXE,
CVE-2022-29801) and a stack based buffer overflow vulnerability
(CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1.
Siemens has released updates for the affected products and recommends
to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect
network access to devices with appropriate mechanisms. In order to
operate the devices in a protected IT environment, Siemens recommends
to configure the environment according to Siemens' operational
guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-
security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found
at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter is affected by XML External Entity Injection (XXE,\nCVE-2022-29801) and a stack based buffer overflow vulnerability\n(CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1.\nSiemens has released updates for the affected products and recommends\nto update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-789162.txt"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-789162.json"
}
],
"title": "SSA-789162: Vulnerabilities in Teamcenter",
"tracking": {
"current_release_date": "2022-08-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-789162",
"initial_release_date": "2022-05-10T00:00:00Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for Teamcenter version line V13.1"
},
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for Teamcenter version line V14.0"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V12.4.0.13",
"product": {
"name": "Teamcenter V12.4",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Teamcenter V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.0.0.9",
"product": {
"name": "Teamcenter V13.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V13.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.2.0.8",
"product": {
"name": "Teamcenter V13.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.3.0.3",
"product": {
"name": "Teamcenter V13.3",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14.0.0.2",
"product": {
"name": "Teamcenter V14.0",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-24290",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.8 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.3 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2022-24290"
},
{
"cve": "CVE-2022-29801",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an\r\nattacker to view files on the application server filesystem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-29801"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…