ssa-885980
Vulnerability from csaf_siemens
Published
2024-04-09 00:00
Modified
2024-04-09 00:00
Summary
SSA-885980: Multiple Vulnerabilities in Scalance W1750D
Notes
Summary
The SCALANCE W1750D devices contain multiple vulnerabilities that could allow an attacker to exploit buffer overflow and information disclosure vulnerabilities which could lead to information disclosure or unauthenticated remote code execution.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "The SCALANCE W1750D devices contain multiple vulnerabilities that could allow an attacker to exploit buffer overflow and information disclosure vulnerabilities which could lead to information disclosure or unauthenticated remote code execution.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-885980: Multiple Vulnerabilities in Scalance W1750D - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-885980.html" }, { "category": "self", "summary": "SSA-885980: Multiple Vulnerabilities in Scalance W1750D - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-885980.json" }, { "category": "self", "summary": "SSA-885980: Multiple Vulnerabilities in Scalance W1750D - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-885980.pdf" }, { "category": "self", "summary": "SSA-885980: Multiple Vulnerabilities in Scalance W1750D - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-885980.txt" } ], "title": "SSA-885980: Multiple Vulnerabilities in Scalance W1750D", "tracking": { "current_release_date": "2024-04-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-885980", "initial_release_date": "2024-04-09T00:00:00Z", "revision_history": [ { "date": "2024-04-09T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV8.10.0.9", "product": { "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AD0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.10.0.9", "product": { "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV8.10.0.9", "product": { "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AB0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-35980", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets\u00a0destined to the PAPI (Aruba\u0027s access point management\u00a0protocol) UDP port (8211). Successful exploitation of these\u00a0vulnerabilities result in the ability to execute arbitrary\u00a0code as a privileged user on the underlying operating system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.10.0.9 or later version\nThe update is available upon request from customer support", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "The CLI and web-based management interfaces should be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "Enabling cluster-security via the cluster-security command will prevent the vulnerabilities from being exploited", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2023-35980" }, { "cve": "CVE-2023-35981", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets\u00a0destined to the PAPI (Aruba\u0027s access point management\u00a0protocol) UDP port (8211). Successful exploitation of these\u00a0vulnerabilities result in the ability to execute arbitrary\u00a0code as a privileged user on the underlying operating system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.10.0.9 or later version\nThe update is available upon request from customer support", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "The CLI and web-based management interfaces should be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "Enabling cluster-security via the cluster-security command will prevent the vulnerabilities from being exploited", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2023-35981" }, { "cve": "CVE-2023-35982", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets\u00a0destined to the PAPI (Aruba\u0027s access point management\u00a0protocol) UDP port (8211). Successful exploitation of these\u00a0vulnerabilities result in the ability to execute arbitrary\u00a0code as a privileged user on the underlying operating system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V8.10.0.9 or later version\nThe update is available upon request from customer support", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "The CLI and web-based management interfaces should be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above", "product_ids": [ "1", "2", "3" ] }, { "category": "workaround", "details": "Enabling cluster-security via the cluster-security command will prevent the vulnerabilities from being exploited", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2023-35982" } ] }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.