VAR-200611-0467
Vulnerability from variot - Updated: 2023-12-18 13:20Heap-based buffer overflow in the wireless driver (WG311ND5.SYS) 2.3.1.10 for NetGear WG311v1 wireless adapter allows remote attackers to execute arbitrary code via an 802.11 management frame with a long SSID. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code, or cause a denial-of-service condition. Failed attempts will likely crash the kernel, resulting in denial-of-service conditions. Although the WG311v1ND5.SYS driver is used primarily on Microsoft Windows, users of Linux and BSD machines running the 'ndiswrapper' tool should determine if they are using a vulnerable instance of the driver. Version 2.3.1.10 of the WG311v1ND5.SYS driver is vulnerable to this issue; other versions may also be affected. WG311 is a 54M wireless PCI card. Remote attackers can trigger this vulnerability by sending specially crafted packets, which may result in denial of service or execution of arbitrary commands. The problem exists in the WG311ND5.SYS driver, which is reproduced on Windows systems, but Linux and FreeBSD may also be affected by similar vulnerabilities.
To improve our services to our customers, we have made a number of additions to the Secunia Advisories and have started translating the advisories to German.
The improvements will help our customers to get a better understanding of how we reached our conclusions, how it was rated, our thoughts on exploitation, attack vectors, and scenarios.
The vulnerability is caused due to a boundary error in the WG311ND5.SYS device driver when handling long SSIDs. This can be exploited to cause a heap-based buffer overflow via a specially crafted packet.
SOLUTION: Turn off the wireless card when not in use.
PROVIDED AND/OR DISCOVERED BY: Laurent Butti
ORIGINAL ADVISORY: http://projects.info-pull.com/mokb/MOKB-22-11-2006.html
About: This Advisory was delivered by Secunia as a free service to help everybody keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-200611-0467",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wg311v1",
"scope": "eq",
"trust": 1.7,
"vendor": "netgear",
"version": "2.3.1.10"
},
{
"model": null,
"scope": null,
"trust": 0.8,
"vendor": "netgear",
"version": null
},
{
"model": "wg311v1",
"scope": "eq",
"trust": 0.8,
"vendor": "net gear",
"version": "2.3.1.10"
},
{
"model": "wg311nd5.sys driver",
"scope": "eq",
"trust": 0.3,
"vendor": "netgear",
"version": "2.3.110"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "BID",
"id": "21251"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:wg311v1:2.3.1.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2006-6125"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Laurent Butti laurent.butti@orange-ftgroup.com",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
],
"trust": 0.6
},
"cve": "CVE-2006-6125",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": true,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2006-6125",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-22233",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2006-6125",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CARNEGIE MELLON",
"id": "VU#403152",
"trust": 0.8,
"value": "0.50"
},
{
"author": "CNNVD",
"id": "CNNVD-200611-410",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-22233",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2006-6125",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Heap-based buffer overflow in the wireless driver (WG311ND5.SYS) 2.3.1.10 for NetGear WG311v1 wireless adapter allows remote attackers to execute arbitrary code via an 802.11 management frame with a long SSID. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code, or cause a denial-of-service condition. Failed attempts will likely crash the kernel, resulting in denial-of-service conditions. \nAlthough the WG311v1ND5.SYS driver is used primarily on Microsoft Windows, users of Linux and BSD machines running the \u0027ndiswrapper\u0027 tool should determine if they are using a vulnerable instance of the driver. \nVersion 2.3.1.10 of the WG311v1ND5.SYS driver is vulnerable to this issue; other versions may also be affected. WG311 is a 54M wireless PCI card. Remote attackers can trigger this vulnerability by sending specially crafted packets, which may result in denial of service or execution of arbitrary commands. The problem exists in the WG311ND5.SYS driver, which is reproduced on Windows systems, but Linux and FreeBSD may also be affected by similar vulnerabilities. \n\n----------------------------------------------------------------------\n\nTo improve our services to our customers, we have made a number of\nadditions to the Secunia Advisories and have started translating the\nadvisories to German. \n\nThe improvements will help our customers to get a better\nunderstanding of how we reached our conclusions, how it was rated,\nour thoughts on exploitation, attack vectors, and scenarios. \n\nThe vulnerability is caused due to a boundary error in the\nWG311ND5.SYS device driver when handling long SSIDs. This can be\nexploited to cause a heap-based buffer overflow via a specially\ncrafted packet. \n\nSOLUTION:\nTurn off the wireless card when not in use. \n\nPROVIDED AND/OR DISCOVERED BY:\nLaurent Butti\n\nORIGINAL ADVISORY:\nhttp://projects.info-pull.com/mokb/MOKB-22-11-2006.html\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\neverybody keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "BID",
"id": "21251"
},
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "PACKETSTORM",
"id": "52470"
}
],
"trust": 2.88
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-22233",
"trust": 0.1,
"type": "unknown"
},
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=29167",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#403152",
"trust": 3.4
},
{
"db": "SECUNIA",
"id": "23051",
"trust": 2.7
},
{
"db": "NVD",
"id": "CVE-2006-6125",
"trust": 2.6
},
{
"db": "BID",
"id": "21251",
"trust": 2.1
},
{
"db": "SECTRACK",
"id": "1017275",
"trust": 1.8
},
{
"db": "VUPEN",
"id": "ADV-2006-4674",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410",
"trust": 0.7
},
{
"db": "EXPLOIT-DB",
"id": "29167",
"trust": 0.2
},
{
"db": "SEEBUG",
"id": "SSVID-82697",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-22233",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2006-6125",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "52470",
"trust": 0.1
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "BID",
"id": "21251"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "PACKETSTORM",
"id": "52470"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"id": "VAR-200611-0467",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-22233"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:20:55.842000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "WG311 Software Version 1.3",
"trust": 0.8,
"url": "http://kb.netgear.com/app/answers/detail/a_id/738"
},
{
"title": "wifuzzit",
"trust": 0.1,
"url": "https://github.com/0xd012/wifuzzit "
},
{
"title": "wifuzzit",
"trust": 0.1,
"url": "https://github.com/flowerhack/wifuzzit "
},
{
"title": "wifuzzit",
"trust": 0.1,
"url": "https://github.com/84kaliplexon3/wifuzzit "
},
{
"title": "wifuzzit",
"trust": 0.1,
"url": "https://github.com/plexone2019/wifuzzit "
},
{
"title": "wifuzzit",
"trust": 0.1,
"url": "https://github.com/wi-fi-analyzer/wifuzzit "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "http://projects.info-pull.com/mokb/mokb-22-11-2006.html"
},
{
"trust": 2.6,
"url": "http://www.kb.cert.org/vuls/id/403152"
},
{
"trust": 1.8,
"url": "http://www.securityfocus.com/bid/21251"
},
{
"trust": 1.8,
"url": "http://securitytracker.com/id?1017275"
},
{
"trust": 1.8,
"url": "http://secunia.com/advisories/23051"
},
{
"trust": 1.2,
"url": "http://www.vupen.com/english/advisories/2006/4674"
},
{
"trust": 0.9,
"url": "http://secunia.com/advisories/23051/"
},
{
"trust": 0.8,
"url": "http://standards.ieee.org/getieee802/download/802.11-1999.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2006-6125"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2006-6125"
},
{
"trust": 0.6,
"url": "http://www.frsirt.com/english/advisories/2006/4674"
},
{
"trust": 0.3,
"url": "http://kbserver.netgear.com/products/wg311v1.asp"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "http://tools.cisco.com/security/center/viewalert.x?alertid=12145"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.exploit-db.com/exploits/29167/"
},
{
"trust": 0.1,
"url": "http://secunia.com/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/product/12717/"
},
{
"trust": 0.1,
"url": "http://corporate.secunia.com/products/48/?r=l"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "http://corporate.secunia.com/how_to_buy/15/?r=l"
},
{
"trust": 0.1,
"url": "http://secunia.com/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "BID",
"id": "21251"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "PACKETSTORM",
"id": "52470"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#403152"
},
{
"db": "VULHUB",
"id": "VHN-22233"
},
{
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"db": "BID",
"id": "21251"
},
{
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"db": "PACKETSTORM",
"id": "52470"
},
{
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2006-11-27T00:00:00",
"db": "CERT/CC",
"id": "VU#403152"
},
{
"date": "2006-11-27T00:00:00",
"db": "VULHUB",
"id": "VHN-22233"
},
{
"date": "2006-11-27T00:00:00",
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"date": "2006-11-22T00:00:00",
"db": "BID",
"id": "21251"
},
{
"date": "2012-09-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"date": "2006-11-26T04:47:38",
"db": "PACKETSTORM",
"id": "52470"
},
{
"date": "2006-11-27T00:07:00",
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"date": "2006-11-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2006-11-27T00:00:00",
"db": "CERT/CC",
"id": "VU#403152"
},
{
"date": "2011-10-17T00:00:00",
"db": "VULHUB",
"id": "VHN-22233"
},
{
"date": "2011-10-17T00:00:00",
"db": "VULMON",
"id": "CVE-2006-6125"
},
{
"date": "2006-11-24T20:35:00",
"db": "BID",
"id": "21251"
},
{
"date": "2012-09-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2004-000632"
},
{
"date": "2011-10-17T04:00:00",
"db": "NVD",
"id": "CVE-2006-6125"
},
{
"date": "2006-11-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NetGear wireless driver fails to properly process specially-crafted 802.11 management frames",
"sources": [
{
"db": "CERT/CC",
"id": "VU#403152"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer overflow",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200611-410"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.