var-201004-0240
Vulnerability from variot
Multiple stack-based buffer overflows in a certain Tetradyne ActiveX control in HP Operations Manager 7.5, 8.10, and 8.16 might allow remote attackers to execute arbitrary code via a long string argument to the (1) LoadFile or (2) SaveFile method, related to srcvw32.dll and srcvw4.dll. HP Operations Manager is prone to a buffer-overflow vulnerability. An attacker may exploit the issue to execute arbitrary code in the context of the application or cause denial-of-service conditions. The following versions are affected: HP Operations Manager for Windows 8.10 HP Operations Manager for Windows 8.16 HP Operations Manager for Windows 7.5. ----------------------------------------------------------------------
Secunia CSI + Microsoft SCCM
= Extensive Patch Management
http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
TITLE: HP Operations Manager SourceView ActiveX Control Buffer Overflow
SECUNIA ADVISORY ID: SA39538
VERIFY ADVISORY: http://secunia.com/advisories/39538/
DESCRIPTION: A vulnerability has been reported in HP Operations Manager, which can be exploited by malicious people to compromise a user's system.
The vulnerability is caused due to a boundary error in the SourceView ActiveX control (srcvw32.dll or srcvw4.dll). This can be exploited to cause a stack-based buffer overflow via an overly long argument passed to e.g. the "LoadFile()" method. Please see the vendor's advisory for more information.
PROVIDED AND/OR DISCOVERED BY: mr_me, Corelan
CHANGELOG: 2010-04-20: Added additional vulnerability information to the advisory. Updated the "Original Advisory" section.
ORIGINAL ADVISORY: HP (HPSBMA02491 SSRT100060): http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02078800
mr_me: http://www.corelan.be:8800/advisories.php?id=CORELAN-10-027
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1
SUPPORT COMMUNICATION - SECURITY BULLETIN
Document ID: c02078800 Version: 1
HPSBMA02491 SSRT100060 rev.1 - HP Operations Manager for Windows, Remote Execution of Arbitrary Code
NOTICE: The information in this Security Bulletin should be acted upon as soon as possible.
Release Date: 2010-04-19 Last Updated: 2010-04-19
Potential Security Impact: Remote execution of arbitrary code
Source: Hewlett-Packard Company, HP Software Security Response Team
VULNERABILITY SUMMARY A potential security vulnerability has been identified with HP Operations Manager for Windows. The vulnerability could be exploited remotely to allow execution of arbitrary code.
References: CVE-2010-1033
SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed.
Note: The appropriate new version, either srcvw4.dll or srcvw32.dll, must be installed on the Operations Manager for Windows management server and on all remote console systems.
For Operations Manager for Windows v8.10 and v8.16
Verify the version of srcvw4.dll currently installed
Right-click on %OvInstallDir%\bin\srcvw4.dll Select Properties Switch to details tab Check File version v4.0.1.1 and earlier are vulnerable
Install required patch
The new version of srcvw4.dll (v4.0.1.2) requires OMW_00060, available here http://support.openview.hp.com/selfsolve/patches
Download the new version of srcvw4.dll
The new version is in the file OMW60_srcvw4.dll, available using ftp:
Host Account Password
ftp.usa.hp.com sb02491 Secure12
Optionally verify the SHA-1 sum: b48f-27e1-15c4-a7ab-d64e-ff65-caf3-543a-dece-16bd OMW60_srcvw4.dll
Install the new version of srcvw4.dl
- From a command prompt, backup %OvInstallDir%\bin\srcvw4.dll
- From a command prompt, copy OMW60_srcvw4.dll into %OvInstallDir%\bin\srcvw4.dll
- Verify that %OvInstallDir%\bin\srcvw4.dll is now v4.0.1.2
Note: Steps 2 and 3 above must be performed from the Windows command line, not from Windows Explorer.
For Operations Manager for Windows v7.5
Verify the version of srcvw32.dll currently installed
Right-click on %OvInstallDir%\bin\srcvw32.dll Select Properties Switch to details tab Check File version v2.23.28 and earlier are vulnerable
Install required patch
The new version of srcvw32.dll (v2.23.29 HP) requires OVOW_00279, available here http://support.openview.hp.com/selfsolve/patches
Download the new version of srcvw32.dll
The new version is in the file OVOW279_srcvw32.dll, available using ftp:
Host Account Password
ftp.usa.hp.com sb02491 Secure12
Optionally verify the SHA-1 sum: 14e5-0530-2ec5-4b4a-3ceb-2e15-9491-6b6e-6ef6-6664 OVOW279_srcvw32.dll
Install the new version of srcvw32.dl
- From a command prompt, backup %OvInstallDir%\bin\srcvw32.dll
- From a command prompt, copy OVOW279_srcvw32.dll into %OvInstallDir%\bin\srcvw32.dll
- Verify that %OvInstallDir%\bin\srcvw32.dll is now v2.23.29 HP
Note: Steps 2 and 3 above must be performed from the Windows command line, not from Windows Explorer.
PRODUCT SPECIFIC INFORMATION None
HISTORY Version:1 (rev.1) - 19 April 2010 Initial release
Third Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer's patch management policy.
Support: For further information, contact normal HP Services support channel.
Report: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com It is strongly recommended that security related information being communicated to HP be encrypted using PGP, especially exploit information. To get the security-alert PGP key, please send an e-mail message as follows: To: security-alert@hp.com Subject: get key Subscribe: To initiate a subscription to receive future HP Security Bulletins via Email: http://h30046.www3.hp.com/driverAlertProfile.php?regioncode=NA&langcode=USENG&jumpid=in_SC-GEN__driverITRC&topiccode=ITRC On the web page: ITRC security bulletins and patch sign-up Under Step1: your ITRC security bulletins and patches -check ALL categories for which alerts are required and continue. Under Step2: your ITRC operating systems -verify your operating system selections are checked and save.
To update an existing subscription: http://h30046.www3.hp.com/subSignIn.php Log in on the web page: Subscriber's choice for Business: sign-in. On the web page: Subscriber's Choice: your profile summary - use Edit Profile to update appropriate sections.
To review previously published Security Bulletins visit: http://www.itrc.hp.com/service/cki/secBullArchive.do
- The Software Product Category that this Security Bulletin relates to is represented by the 5th and 6th characters of the Bulletin number in the title:
GN = HP General SW MA = HP Management Agents MI = Misc. 3rd Party SW MP = HP MPE/iX NS = HP NonStop Servers OV = HP OpenVMS PI = HP Printing & Imaging ST = HP Storage SW TL = HP Trusted Linux TU = HP Tru64 UNIX UX = HP-UX VV = HP VirtualVault
System management and security procedures must be reviewed frequently to maintain system integrity. HP is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions.
"HP is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HP products the important security information contained in this Bulletin. HP recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HP does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HP will not be responsible for any damages resulting from user's use or disregard of the information provided in this Bulletin. To the extent permitted by law, HP disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement."
Copyright 2009 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits;damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett-Packard Company and the names of Hewlett-Packard products referenced herein are trademarks of Hewlett-Packard Company in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.10 (GNU/Linux)
iEYEARECAAYFAkvMWXcACgkQ4B86/C0qfVmlggCgzdS8Z18Skq1Q5AQRkgGF3Maf 9X0AoJPetBb8SbNjR2JRkSjcDe42S8CI =kTbM -----END PGP SIGNATURE-----
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201004-0240", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "operations manager", "scope": "eq", "trust": 1.6, "vendor": "hp", "version": "7.5" }, { "model": "operations manager", "scope": "eq", "trust": 1.6, "vendor": "hp", "version": "8.16" }, { "model": "operations manager", "scope": "eq", "trust": 1.6, "vendor": "hp", "version": "8.10" }, { "model": "hp operations manager", "scope": "eq", "trust": 0.8, "vendor": "hewlett packard", "version": "7.5" }, { "model": "hp operations manager", "scope": "eq", "trust": 0.8, "vendor": "hewlett packard", "version": "8.10" }, { "model": "hp operations manager", "scope": "eq", "trust": 0.8, "vendor": "hewlett packard", "version": "and 8.16" }, { "model": "openview operations manager for windows", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "8.16" }, { "model": "openview operations manager for windows", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "8.1" }, { "model": "openview operations manager for windows", "scope": "eq", "trust": 0.3, "vendor": "hp", "version": "7.5" } ], "sources": [ { "db": "BID", "id": "39578" }, { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "CNNVD", "id": "CNNVD-201004-363" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:hp:operations_manager:8.16:*:windows:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:hp:operations_manager:7.5:*:windows:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:hp:operations_manager:8.10:*:windows:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2010-1033" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "mr_me from Corelan Team", "sources": [ { "db": "BID", "id": "39578" } ], "trust": 0.3 }, "cve": "CVE-2010-1033", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 9.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2010-1033", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 1.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "NVD", "id": "CVE-2010-1033", "trust": 1.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201004-363", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "CNNVD", "id": "CNNVD-201004-363" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple stack-based buffer overflows in a certain Tetradyne ActiveX control in HP Operations Manager 7.5, 8.10, and 8.16 might allow remote attackers to execute arbitrary code via a long string argument to the (1) LoadFile or (2) SaveFile method, related to srcvw32.dll and srcvw4.dll. HP Operations Manager is prone to a buffer-overflow vulnerability. \nAn attacker may exploit the issue to execute arbitrary code in the context of the application or cause denial-of-service conditions. \nThe following versions are affected:\nHP Operations Manager for Windows 8.10\nHP Operations Manager for Windows 8.16\nHP Operations Manager for Windows 7.5. ----------------------------------------------------------------------\n\n\n Secunia CSI\n+ Microsoft SCCM\n-----------------------\n= Extensive Patch Management\n\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\n\n----------------------------------------------------------------------\n\nTITLE:\nHP Operations Manager SourceView ActiveX Control Buffer Overflow\n\nSECUNIA ADVISORY ID:\nSA39538\n\nVERIFY ADVISORY:\nhttp://secunia.com/advisories/39538/\n\nDESCRIPTION:\nA vulnerability has been reported in HP Operations Manager, which can\nbe exploited by malicious people to compromise a user\u0027s system. \n\nThe vulnerability is caused due to a boundary error in the SourceView\nActiveX control (srcvw32.dll or srcvw4.dll). This can be exploited to\ncause a stack-based buffer overflow via an overly long argument\npassed to e.g. the \"LoadFile()\" method. Please see the\nvendor\u0027s advisory for more information. \n\nPROVIDED AND/OR DISCOVERED BY:\nmr_me, Corelan\n\nCHANGELOG:\n2010-04-20: Added additional vulnerability information to the\nadvisory. Updated the \"Original Advisory\" section. \n\nORIGINAL ADVISORY:\nHP (HPSBMA02491 SSRT100060):\nhttp://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02078800\n\nmr_me:\nhttp://www.corelan.be:8800/advisories.php?id=CORELAN-10-027\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA1\n\nSUPPORT COMMUNICATION - SECURITY BULLETIN\n\nDocument ID: c02078800\nVersion: 1\n\nHPSBMA02491 SSRT100060 rev.1 - HP Operations Manager for Windows, Remote Execution of Arbitrary Code\n\nNOTICE: The information in this Security Bulletin should be acted upon as soon as possible. \n\nRelease Date: 2010-04-19\nLast Updated: 2010-04-19\n\nPotential Security Impact: Remote execution of arbitrary code\n\nSource: Hewlett-Packard Company, HP Software Security Response Team\n\nVULNERABILITY SUMMARY\nA potential security vulnerability has been identified with HP Operations Manager for Windows. The vulnerability could be exploited remotely to allow execution of arbitrary code. \n\nReferences: CVE-2010-1033\n\nSUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. \n\nNote: The appropriate new version, either srcvw4.dll or srcvw32.dll, must be installed on the Operations Manager for Windows management server and on all remote console systems. \n\nFor Operations Manager for Windows v8.10 and v8.16\n\nVerify the version of srcvw4.dll currently installed\n\nRight-click on %OvInstallDir%\\bin\\srcvw4.dll\nSelect Properties\nSwitch to details tab\nCheck File version\nv4.0.1.1 and earlier are vulnerable\n\nInstall required patch\n\nThe new version of srcvw4.dll (v4.0.1.2) requires OMW_00060, available here http://support.openview.hp.com/selfsolve/patches\n\nDownload the new version of srcvw4.dll\n\nThe new version is in the file OMW60_srcvw4.dll, available using ftp:\n\nHost\n Account\n Password\n\nftp.usa.hp.com\n sb02491\n Secure12\n\nOptionally verify the SHA-1 sum:\nb48f-27e1-15c4-a7ab-d64e-ff65-caf3-543a-dece-16bd OMW60_srcvw4.dll\n\nInstall the new version of srcvw4.dl\n\n1. \n2. From a command prompt, backup %OvInstallDir%\\bin\\srcvw4.dll\n3. From a command prompt, copy OMW60_srcvw4.dll into %OvInstallDir%\\bin\\srcvw4.dll\n4. Verify that %OvInstallDir%\\bin\\srcvw4.dll is now v4.0.1.2\n\nNote: Steps 2 and 3 above must be performed from the Windows command line, not from Windows Explorer. \n\nFor Operations Manager for Windows v7.5\n\nVerify the version of srcvw32.dll currently installed\n\nRight-click on %OvInstallDir%\\bin\\srcvw32.dll\nSelect Properties\nSwitch to details tab\nCheck File version\nv2.23.28 and earlier are vulnerable\n\nInstall required patch\n\nThe new version of srcvw32.dll (v2.23.29 HP) requires OVOW_00279, available here http://support.openview.hp.com/selfsolve/patches\n\nDownload the new version of srcvw32.dll\n\nThe new version is in the file OVOW279_srcvw32.dll, available using ftp:\n\nHost\n Account\n Password\n\nftp.usa.hp.com\n sb02491\n Secure12\n\nOptionally verify the SHA-1 sum:\n14e5-0530-2ec5-4b4a-3ceb-2e15-9491-6b6e-6ef6-6664 OVOW279_srcvw32.dll\n\nInstall the new version of srcvw32.dl\n\n1. \n2. From a command prompt, backup %OvInstallDir%\\bin\\srcvw32.dll\n3. From a command prompt, copy OVOW279_srcvw32.dll into %OvInstallDir%\\bin\\srcvw32.dll\n4. Verify that %OvInstallDir%\\bin\\srcvw32.dll is now v2.23.29 HP\n\nNote: Steps 2 and 3 above must be performed from the Windows command line, not from Windows Explorer. \n\nPRODUCT SPECIFIC INFORMATION\nNone\n\nHISTORY\nVersion:1 (rev.1) - 19 April 2010 Initial release\n\nThird Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer\u0027s patch management policy. \n\nSupport: For further information, contact normal HP Services support channel. \n\nReport: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com\nIt is strongly recommended that security related information being communicated to HP be encrypted using PGP, especially exploit information. \nTo get the security-alert PGP key, please send an e-mail message as follows:\n To: security-alert@hp.com\n Subject: get key\nSubscribe: To initiate a subscription to receive future HP Security Bulletins via Email:\nhttp://h30046.www3.hp.com/driverAlertProfile.php?regioncode=NA\u0026langcode=USENG\u0026jumpid=in_SC-GEN__driverITRC\u0026topiccode=ITRC\nOn the web page: ITRC security bulletins and patch sign-up\nUnder Step1: your ITRC security bulletins and patches\n -check ALL categories for which alerts are required and continue. \nUnder Step2: your ITRC operating systems\n -verify your operating system selections are checked and save. \n\nTo update an existing subscription: http://h30046.www3.hp.com/subSignIn.php\nLog in on the web page: Subscriber\u0027s choice for Business: sign-in. \nOn the web page: Subscriber\u0027s Choice: your profile summary - use Edit Profile to update appropriate sections. \n\nTo review previously published Security Bulletins visit: http://www.itrc.hp.com/service/cki/secBullArchive.do\n\n* The Software Product Category that this Security Bulletin\nrelates to is represented by the 5th and 6th characters\nof the Bulletin number in the title:\n\nGN = HP General SW\nMA = HP Management Agents\nMI = Misc. 3rd Party SW\nMP = HP MPE/iX\nNS = HP NonStop Servers\nOV = HP OpenVMS\nPI = HP Printing \u0026 Imaging\nST = HP Storage SW\nTL = HP Trusted Linux\nTU = HP Tru64 UNIX\nUX = HP-UX\nVV = HP VirtualVault\n\nSystem management and security procedures must be reviewed frequently to maintain system integrity. HP is continually reviewing and enhancing the security features of software products to provide customers with current secure solutions. \n\n\"HP is broadly distributing this Security Bulletin in order to bring to the attention of users of the affected HP products the important security information contained in this Bulletin. HP recommends that all users determine the applicability of this information to their individual situations and take appropriate action. HP does not warrant that this information is necessarily accurate or complete for all user situations and, consequently, HP will not be responsible for any damages resulting from user\u0027s use or disregard of the information provided in this Bulletin. To the extent permitted by law, HP disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose, title and non-infringement.\"\n\nCopyright 2009 Hewlett-Packard Development Company, L.P. \nHewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided \"as is\" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits;damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett-Packard Company and the names of Hewlett-Packard products referenced herein are trademarks of Hewlett-Packard Company in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1.4.10 (GNU/Linux)\n\niEYEARECAAYFAkvMWXcACgkQ4B86/C0qfVmlggCgzdS8Z18Skq1Q5AQRkgGF3Maf\n9X0AoJPetBb8SbNjR2JRkSjcDe42S8CI\n=kTbM\n-----END PGP SIGNATURE-----\n", "sources": [ { "db": "NVD", "id": "CVE-2010-1033" }, { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "BID", "id": "39578" }, { "db": "PACKETSTORM", "id": "88722" }, { "db": "PACKETSTORM", "id": "88747" } ], "trust": 2.07 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2010-1033", "trust": 2.8 }, { "db": "BID", "id": "39578", "trust": 1.9 }, { "db": "SECUNIA", "id": "39538", "trust": 1.7 }, { "db": "VUPEN", "id": "ADV-2010-0946", "trust": 1.6 }, { "db": "SECTRACK", "id": "1023894", "trust": 1.6 }, { "db": "JVNDB", "id": "JVNDB-2010-004596", "trust": 0.8 }, { "db": "HP", "id": "SSRT100060", "trust": 0.6 }, { "db": "HP", "id": "HPSBMA02491", "trust": 0.6 }, { "db": "XF", "id": "57938", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201004-363", "trust": 0.6 }, { "db": "PACKETSTORM", "id": "88722", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "88747", "trust": 0.1 } ], "sources": [ { "db": "BID", "id": "39578" }, { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "PACKETSTORM", "id": "88722" }, { "db": "PACKETSTORM", "id": "88747" }, { "db": "CNNVD", "id": "CNNVD-201004-363" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "id": "VAR-201004-0240", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.11111111 }, "last_update_date": "2022-05-04T10:20:12.201000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "HPSBMA02491 SSRT100060", "trust": 0.8, "url": "http://h20000.www2.hp.com/bizsupport/techsupport/document.jsp?objectid=c02078800" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2010-004596" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "http://h20000.www2.hp.com/bizsupport/techsupport/document.jsp?objectid=c02078800" }, { "trust": 1.7, "url": "http://www.corelan.be:8800/advisories.php?id=corelan-10-027" }, { "trust": 1.6, "url": "http://www.vupen.com/english/advisories/2010/0946" }, { "trust": 1.6, "url": "http://www.securityfocus.com/bid/39578" }, { "trust": 1.6, "url": "http://www.corelan.be:8800/wp-content/forum-file-uploads/mr_me/hpoperationsmngr.html.txt" }, { "trust": 1.6, "url": "http://securitytracker.com/id?1023894" }, { "trust": 1.6, "url": "http://secunia.com/advisories/39538" }, { "trust": 1.6, "url": "http://net-ninja.net/blog/media/blogs/b/exploits/hpoperationsmngr.html.txt" }, { "trust": 1.0, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/57938" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2010-1033" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2010-1033" }, { "trust": 0.6, "url": "http://xforce.iss.net/xforce/xfdb/57938" }, { "trust": 0.3, "url": "https://h10078.www1.hp.com/cda/hpms/display/main/hpms_content.jsp?zn=bto\u0026cp=1-11-15-28^1745_4000_100__" }, { "trust": 0.1, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.1, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.1, "url": "http://secunia.com/advisories/39538/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/about_secunia_advisories/" }, { "trust": 0.1, "url": "https://nvd.nist.gov/vuln/detail/cve-2010-1033" }, { "trust": 0.1, "url": "http://www.itrc.hp.com/service/cki/secbullarchive.do" }, { "trust": 0.1, "url": "http://h30046.www3.hp.com/driveralertprofile.php?regioncode=na\u0026langcode=useng\u0026jumpid=in_sc-gen__driveritrc\u0026topiccode=itrc" }, { "trust": 0.1, "url": "http://h30046.www3.hp.com/subsignin.php" }, { "trust": 0.1, "url": "http://support.openview.hp.com/selfsolve/patches" } ], "sources": [ { "db": "BID", "id": "39578" }, { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "PACKETSTORM", "id": "88722" }, { "db": "PACKETSTORM", "id": "88747" }, { "db": "CNNVD", "id": "CNNVD-201004-363" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "BID", "id": "39578" }, { "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "db": "PACKETSTORM", "id": "88722" }, { "db": "PACKETSTORM", "id": "88747" }, { "db": "CNNVD", "id": "CNNVD-201004-363" }, { "db": "NVD", "id": "CVE-2010-1033" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2010-04-19T00:00:00", "db": "BID", "id": "39578" }, { "date": "2012-09-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "date": "2010-04-20T14:56:50", "db": "PACKETSTORM", "id": "88722" }, { "date": "2010-04-21T14:34:53", "db": "PACKETSTORM", "id": "88747" }, { "date": "2010-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201004-363" }, { "date": "2010-04-21T14:30:00", "db": "NVD", "id": "CVE-2010-1033" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2010-04-19T00:00:00", "db": "BID", "id": "39578" }, { "date": "2012-09-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2010-004596" }, { "date": "2010-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-201004-363" }, { "date": "2017-08-17T01:32:00", "db": "NVD", "id": "CVE-2010-1033" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201004-363" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "HP Operations Manager Vulnerable to stack-based buffer overflow", "sources": [ { "db": "JVNDB", "id": "JVNDB-2010-004596" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer overflow", "sources": [ { "db": "CNNVD", "id": "CNNVD-201004-363" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.