VAR-201112-0060
Vulnerability from variot - Updated: 2023-12-18 12:31Multiple buffer overflows in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11355 and earlier allow remote attackers to execute arbitrary code or cause a denial of service via a crafted packet to TCP port (1) 12397 or (2) 12399. The 7T Interactive Graphical SCADA System is an automated monitoring and control system. This vulnerability can be triggered by sending more than a specially crafted data message to TCP 12399 or 12397. 7-Technologies Interactive Graphical SCADA System is prone to a buffer-overflow vulnerability. Failed exploit attempts likely result in denial-of-service conditions. 7-Technologies Interactive Graphical SCADA System 9.0.0.11355 and prior versions are vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201112-0060",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "igss",
"scope": "lte",
"trust": 1.0,
"vendor": "7t",
"version": "9.0.0.11355"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "8"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "9"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "9.0.0.11143"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "9.0.0.11200"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "9.0.0.11355"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "7"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.9,
"vendor": "7",
"version": "9.0.0.11129"
},
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 0.8,
"vendor": "7",
"version": "9.0.0.11355"
},
{
"model": "igss",
"scope": "eq",
"trust": 0.6,
"vendor": "7t",
"version": "9.0.0.11355"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "igss",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:7t:igss:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "9.0.0.11355",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2011-4537"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Celil Unuver of SignalSEC LLC",
"sources": [
{
"db": "BID",
"id": "51157"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
],
"trust": 0.9
},
"cve": "CVE-2011-4537",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2011-4537",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "454a46ac-2354-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2011-4537",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201112-405",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple buffer overflows in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11355 and earlier allow remote attackers to execute arbitrary code or cause a denial of service via a crafted packet to TCP port (1) 12397 or (2) 12399. The 7T Interactive Graphical SCADA System is an automated monitoring and control system. This vulnerability can be triggered by sending more than a specially crafted data message to TCP 12399 or 12397. 7-Technologies Interactive Graphical SCADA System is prone to a buffer-overflow vulnerability. Failed exploit attempts likely result in denial-of-service conditions. \n7-Technologies Interactive Graphical SCADA System 9.0.0.11355 and prior versions are vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
},
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
}
],
"trust": 2.61
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2011-4537",
"trust": 3.5
},
{
"db": "ICS CERT",
"id": "ICSA-11-355-01",
"trust": 3.3
},
{
"db": "OSVDB",
"id": "77977",
"trust": 1.6
},
{
"db": "BID",
"id": "51157",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2011-5414",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552",
"trust": 0.8
},
{
"db": "XF",
"id": "71931",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "18381",
"trust": 0.6
},
{
"db": "IVD",
"id": "454A46AC-2354-11E6-ABEF-000C29C66E3D",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"id": "VAR-201112-0060",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
}
],
"trust": 1.46741073
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
}
]
},
"last_update_date": "2023-12-18T12:31:19.565000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.igss.com/index.htm\\"
},
{
"title": "7-Technologies Interactive Graphical SCADA System Buffer Overflow Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/6431"
},
{
"title": "progupdatesv90",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=42233"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.3,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-355-01-7.pdf"
},
{
"trust": 1.6,
"url": "http://www.osvdb.org/77977"
},
{
"trust": 1.0,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71931"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4537"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4537"
},
{
"trust": 0.6,
"url": "http://xforce.iss.net/xforce/xfdb/71931"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/51157"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/18381"
},
{
"trust": 0.3,
"url": "http://www.igss.com/index.htm"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-12-23T00:00:00",
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"date": "2011-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"date": "2011-12-21T00:00:00",
"db": "BID",
"id": "51157"
},
{
"date": "2011-12-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"date": "2011-12-27T04:01:39.890000",
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"date": "1900-01-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-12-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"date": "2011-12-21T00:00:00",
"db": "BID",
"id": "51157"
},
{
"date": "2011-12-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-003552"
},
{
"date": "2017-08-29T01:30:30.520000",
"db": "NVD",
"id": "CVE-2011-4537"
},
{
"date": "2012-01-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "7-Technologies Interactive Graphical SCADA System Buffer Overflow Vulnerability",
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5414"
},
{
"db": "BID",
"id": "51157"
}
],
"trust": 1.1
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow",
"sources": [
{
"db": "IVD",
"id": "454a46ac-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201112-405"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…