var-201202-0049
Vulnerability from variot

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0049",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "cve": "CVE-2011-4514",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2011-4514",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "28d0ca64-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52459",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2011-4514",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-089",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28d0ca64-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52459",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4514",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "28D0CA64-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "id": "VAR-201202-0049",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      }
    ],
    "trust": 1.494686884
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:22:07.510000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Telnet Vulnerability (CNVD-2012-0464)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/9062"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4514"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4514"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "date": "2012-02-03T20:55:01.577000",
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "date": "2012-02-06T05:00:00",
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  TELNET Access vulnerability in daemon",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.