var-201206-0073
Vulnerability from variot
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL. WinCC flexible is a human-machine interface for use in some machine or process applications. An attacker can exploit the vulnerability to read arbitrary files. Siemens SIMATIC WinCC Flexible is prone to multiple security vulnerabilities. Attackers can exploit these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site, execute arbitrary code in the context of the affected application, read arbitrary files on the system, redirect users to a potentially malicious site, access or modify data of an XML document, or cause denial-of-service conditions; other attacks may also be possible.
The vulnerability is caused due to an input sanitisation error within the DiagAgent web server and can be exploited to cause a buffer overflow and crash the DiagAgent.
Successful exploitation requires the DiagAgent web server to be enabled (disabled by default). ----------------------------------------------------------------------
Become a PSI 3.0 beta tester! Test-drive the new beta version and tell us what you think about its extended automatic update function and significantly enhanced user-interface. Download it here! http://secunia.com/psi_30_beta_launch
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA49341
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/49341/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=49341
RELEASE DATE: 2012-06-07
DISCUSS ADVISORY: http://secunia.com/advisories/49341/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/49341/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=49341
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: A weakness and some vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious users to disclose potentially sensitive information and system information and manipulate certain data and by malicious people to conduct spoofing and cross-site scripting attacks.
1) Certain input passed via URL parameters to two unspecified web applications is not properly sanitised before being used to construct a XPath query for XML data. This can be exploited to manipulate XPath queries by injecting arbitrary XPath code and e.g. read or write certain system settings.
2) Certain input passed via a filename to two unspecified web applications is not properly verified before being used to display files. This can be exploited to disclose the contents of arbitrary files via directory traversal sequences.
3) Certain input passed to two unspecified web applications is not properly sanitised before being returned to the user.
4) Certain input is not properly verified before being used to redirect users. This can be exploited to redirect a user to an arbitrary website e.g. when a user clicks a specially crafted link to the affected script hosted on a trusted domain.
The weakness and the vulnerabilities are reported in version 7.0 SP3.
SOLUTION: Apply "Update 2" (please see the vendor's advisory for details).
PROVIDED AND/OR DISCOVERED BY: 1-3) The vendor credits Gleb Gritsai, Alexander Zaitsev, Sergey Scherbel, Yuri Goltsev, Dmitry Serebryannikov, Sergey Bobrov, Denis Baranov, and Andrey Medov, Positive Technologies. 4) Reported by the vendor.
ORIGINAL ADVISORY: Siemens: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf
ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201206-0073", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "7.0" }, { "model": "wincc sp3", "scope": "eq", "trust": 0.9, "vendor": "siemens", "version": "7.0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "update 2" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "7.0 sp3" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "7.0" } ], "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "BID", "id": "53837" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:update_1:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2012-2597" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Gleb Gritsai, Alexander Zaitsev, Sergey Scherbel, Yuri Goltsev, Dmitry Serebryannikov, Sergey Bobrov, Denis Baranov, Andrey Medov and Siemens", "sources": [ { "db": "BID", "id": "53837" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ], "trust": 0.9 }, "cve": "CVE-2012-2597", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2012-2597", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "c4c1d040-2353-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "VHN-55878", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "NVD", "id": "CVE-2012-2597", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201206-086", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-55878", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-55878" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL. WinCC flexible is a human-machine interface for use in some machine or process applications. An attacker can exploit the vulnerability to read arbitrary files. Siemens SIMATIC WinCC Flexible is prone to multiple security vulnerabilities. \nAttackers can exploit these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site, execute arbitrary code in the context of the affected application, read arbitrary files on the system, redirect users to a potentially malicious site, access or modify data of an XML document, or cause denial-of-service conditions; other attacks may also be possible. \n\nThe vulnerability is caused due to an input sanitisation error within\nthe DiagAgent web server and can be exploited to cause a buffer\noverflow and crash the DiagAgent. \n\nSuccessful exploitation requires the DiagAgent web server to be\nenabled (disabled by default). ----------------------------------------------------------------------\n\nBecome a PSI 3.0 beta tester!\nTest-drive the new beta version and tell us what you think about its extended automatic update function and significantly enhanced user-interface. \nDownload it here!\nhttp://secunia.com/psi_30_beta_launch\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA49341\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/49341/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49341\n\nRELEASE DATE:\n2012-06-07\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/49341/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/49341/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49341\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA weakness and some vulnerabilities have been reported in Siemens\nSIMATIC WinCC, which can be exploited by malicious users to disclose\npotentially sensitive information and system information and\nmanipulate certain data and by malicious people to conduct spoofing\nand cross-site scripting attacks. \n\n1) Certain input passed via URL parameters to two unspecified web\napplications is not properly sanitised before being used to construct\na XPath query for XML data. This can be exploited to manipulate XPath\nqueries by injecting arbitrary XPath code and e.g. read or write\ncertain system settings. \n\n2) Certain input passed via a filename to two unspecified web\napplications is not properly verified before being used to display\nfiles. This can be exploited to disclose the contents of arbitrary\nfiles via directory traversal sequences. \n\n3) Certain input passed to two unspecified web applications is not\nproperly sanitised before being returned to the user. \n\n4) Certain input is not properly verified before being used to\nredirect users. This can be exploited to redirect a user to an\narbitrary website e.g. when a user clicks a specially crafted link to\nthe affected script hosted on a trusted domain. \n\nThe weakness and the vulnerabilities are reported in version 7.0 SP3. \n\nSOLUTION:\nApply \"Update 2\" (please see the vendor\u0027s advisory for details). \n\nPROVIDED AND/OR DISCOVERED BY:\n1-3) The vendor credits Gleb Gritsai, Alexander Zaitsev, Sergey\nScherbel, Yuri Goltsev, Dmitry Serebryannikov, Sergey Bobrov, Denis\nBaranov, and Andrey Medov, Positive Technologies. \n4) Reported by the vendor. \n\nORIGINAL ADVISORY:\nSiemens:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf\n\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "BID", "id": "53837" }, { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-55878" }, { "db": "PACKETSTORM", "id": "113374" }, { "db": "PACKETSTORM", "id": "113371" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2012-2597", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-12-158-01", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-223158", "trust": 1.9 }, { "db": "CNNVD", "id": "CNNVD-201206-086", "trust": 0.9 }, { "db": "BID", "id": "53837", "trust": 0.9 }, { "db": "SECUNIA", "id": "49341", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-3213", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-002660", "trust": 0.8 }, { "db": "NSFOCUS", "id": "19751", "trust": 0.6 }, { "db": "SECUNIA", "id": "49359", "trust": 0.3 }, { "db": "IVD", "id": "C4C1D040-2353-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-55878", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "113374", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "113371", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "VULHUB", "id": "VHN-55878" }, { "db": "BID", "id": "53837" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "PACKETSTORM", "id": "113374" }, { "db": "PACKETSTORM", "id": "113371" }, { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "id": "VAR-201206-0073", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "VULHUB", "id": "VHN-55878" } ], "trust": 1.5935203766666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" } ] }, "last_update_date": "2023-12-18T12:38:49.284000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-223158: Multiple Vulnerabilities in WinCC 7.0 SP3", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for the Siemens WinCC Directory Traversal Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/18133" }, { "title": "Update 2 for WinCC V7.0 SP3 und WinCC V7.0 SP3 ASIA", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=43310" }, { "title": "Update 2 for WinCC V7.0 SP3 und WinCC V7.0 SP3 ASIA", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=43309" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-55878" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "NVD", "id": "CVE-2012-2597" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.6, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-158-01.pdf" }, { "trust": 1.9, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-2597" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-2597" }, { "trust": 0.6, "url": "http://secunia.com/advisories/49341" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/53837" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/19751" }, { "trust": 0.3, "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx" }, { "trust": 0.2, "url": "http://secunia.com/psi_30_beta_launch" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.2, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.2, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.2, "url": "http://secunia.com/advisories/about_secunia_advisories/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/49359/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/49359/#comments" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49359" }, { "trust": 0.1, "url": "http://secunia.com/advisories/49341/" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=49341" }, { "trust": 0.1, "url": "http://secunia.com/advisories/49341/#comments" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "VULHUB", "id": "VHN-55878" }, { "db": "BID", "id": "53837" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "PACKETSTORM", "id": "113374" }, { "db": "PACKETSTORM", "id": "113371" }, { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "VULHUB", "id": "VHN-55878" }, { "db": "BID", "id": "53837" }, { "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "db": "PACKETSTORM", "id": "113374" }, { "db": "PACKETSTORM", "id": "113371" }, { "db": "NVD", "id": "CVE-2012-2597" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-06-19T00:00:00", "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "date": "2012-06-19T00:00:00", "db": "CNVD", "id": "CNVD-2012-3213" }, { "date": "2012-06-08T00:00:00", "db": "VULHUB", "id": "VHN-55878" }, { "date": "2012-06-06T00:00:00", "db": "BID", "id": "53837" }, { "date": "2012-06-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "date": "2012-06-08T07:05:53", "db": "PACKETSTORM", "id": "113374" }, { "date": "2012-06-08T07:05:43", "db": "PACKETSTORM", "id": "113371" }, { "date": "2012-06-08T18:55:02.267000", "db": "NVD", "id": "CVE-2012-2597" }, { "date": "2012-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-06-19T00:00:00", "db": "CNVD", "id": "CNVD-2012-3213" }, { "date": "2012-06-12T00:00:00", "db": "VULHUB", "id": "VHN-55878" }, { "date": "2012-06-06T00:00:00", "db": "BID", "id": "53837" }, { "date": "2012-06-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-002660" }, { "date": "2012-06-12T04:00:00", "db": "NVD", "id": "CVE-2012-2597" }, { "date": "2012-06-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201206-086" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201206-086" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens WinCC Directory Traversal Vulnerability", "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-3213" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ], "trust": 1.4 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Path traversal", "sources": [ { "db": "IVD", "id": "c4c1d040-2353-11e6-abef-000c29c66e3d" }, { "db": "CNNVD", "id": "CNNVD-201206-086" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.