var-201209-0223
Vulnerability from variot
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201209-0223", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "7.0" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "5.0" }, { "model": "wincc", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "6.0" }, { "model": "simatic pcs7", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "8.0" }, { "model": "wincc", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "7.0" }, { "model": null, "scope": "eq", "trust": 0.8, "vendor": "wincc", "version": "6.0" }, { "model": "simatic pcs 7", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic wincc", "scope": "lte", "trust": 0.8, "vendor": "siemens", "version": "7.0 sp3" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "wincc", "version": "7.0" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7.x" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "77.x" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "wincc", "version": "5.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pcs7", "version": "8.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "wincc", "version": "*" } ], "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "7.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2012-3030" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Denis Baranov Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov,Timur Yunusov from Positive Technologies", "sources": [ { "db": "CNNVD", "id": "CNNVD-201209-293" } ], "trust": 0.6 }, "cve": "CVE-2012-3030", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2012-3030", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "5dd6af86-2353-11e6-abef-000c29c66e3d", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "VHN-56311", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "NVD", "id": "CVE-2012-3030", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201209-293", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-56311", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-56311" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n", "sources": [ { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "BID", "id": "55492" }, { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-56311" }, { "db": "PACKETSTORM", "id": "116445" }, { "db": "PACKETSTORM", "id": "116447" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2012-3030", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-864051", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-12-256-01", "trust": 2.5 }, { "db": "CNNVD", "id": "CNNVD-201209-293", "trust": 0.9 }, { "db": "BID", "id": "55492", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2012-5083", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2012-004447", "trust": 0.8 }, { "db": "SECUNIA", "id": "50568", "trust": 0.8 }, { "db": "NSFOCUS", "id": "20651", "trust": 0.6 }, { "db": "NSFOCUS", "id": "20932", "trust": 0.6 }, { "db": "IVD", "id": "5DD6AF86-2353-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "SECUNIA", "id": "50581", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-56311", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "116445", "trust": 0.1 }, { "db": "PACKETSTORM", "id": "116447", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "VULHUB", "id": "VHN-56311" }, { "db": "BID", "id": "55492" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "PACKETSTORM", "id": "116445" }, { "db": "PACKETSTORM", "id": "116447" }, { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "id": "VAR-201209-0223", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "VULHUB", "id": "VHN-56311" } ], "trust": 1.49052891 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" } ] }, "last_update_date": "2023-12-18T12:58:16.139000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "http://www.siemens.com/" }, { "title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3", "trust": 0.8, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc", "trust": 0.8, "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx" }, { "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e", "trust": 0.8, "url": "http://www.siemens.com/entry/jp/ja/" }, { "title": "Patch for Siemens SIMATIC WinCC arbitrary file read vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/22131" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-264", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-56311" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "NVD", "id": "CVE-2012-3030" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf" }, { "trust": 1.9, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "trust": 1.7, "url": "http://en.securitylab.ru/lab/pt-2012-43" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3030" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3030" }, { "trust": 0.6, "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp" }, { "trust": 0.6, "url": "http://secunia.com/advisories/50568" }, { "trust": 0.6, "url": "http://www.securityfocus.com/bid/55492" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/20932" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/20651" }, { "trust": 0.3, "url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_intelligence/" }, { "trust": 0.2, "url": "http://secunia.com/advisories/secunia_security_advisories/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/" }, { "trust": 0.2, "url": "http://secunia.com/vulnerability_scanning/personal/" }, { "trust": 0.2, "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org" }, { "trust": 0.2, "url": "http://secunia.com/blog/325/" }, { "trust": 0.2, "url": "http://secunia.com/advisories/about_secunia_advisories/" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581" }, { "trust": 0.1, "url": "http://secunia.com/advisories/50581/#comments" }, { "trust": 0.1, "url": "http://secunia.com/advisories/50581/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/50568/" }, { "trust": 0.1, "url": "http://secunia.com/advisories/50568/#comments" }, { "trust": 0.1, "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "VULHUB", "id": "VHN-56311" }, { "db": "BID", "id": "55492" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "PACKETSTORM", "id": "116445" }, { "db": "PACKETSTORM", "id": "116447" }, { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" }, { "db": "VULHUB", "id": "VHN-56311" }, { "db": "BID", "id": "55492" }, { "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "db": "PACKETSTORM", "id": "116445" }, { "db": "PACKETSTORM", "id": "116447" }, { "db": "NVD", "id": "CVE-2012-3030" }, { "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-09-13T00:00:00", "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "date": "2012-09-13T00:00:00", "db": "CNVD", "id": "CNVD-2012-5083" }, { "date": "2012-09-18T00:00:00", "db": "VULHUB", "id": "VHN-56311" }, { "date": "2012-09-11T00:00:00", "db": "BID", "id": "55492" }, { "date": "2012-09-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "date": "2012-09-11T07:30:00", "db": "PACKETSTORM", "id": "116445" }, { "date": "2012-09-11T07:30:06", "db": "PACKETSTORM", "id": "116447" }, { "date": "2012-09-18T14:55:01.443000", "db": "NVD", "id": "CVE-2012-3030" }, { "date": "2012-09-18T00:00:00", "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2012-09-13T00:00:00", "db": "CNVD", "id": "CNVD-2012-5083" }, { "date": "2012-12-20T00:00:00", "db": "VULHUB", "id": "VHN-56311" }, { "date": "2012-09-12T22:50:00", "db": "BID", "id": "55492" }, { "date": "2012-09-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2012-004447" }, { "date": "2012-12-20T05:00:00", "db": "NVD", "id": "CVE-2012-3030" }, { "date": "2012-09-20T00:00:00", "db": "CNNVD", "id": "CNNVD-201209-293" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201209-293" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC WinCC Arbitrary File Read Vulnerability", "sources": [ { "db": "IVD", "id": "5dd6af86-2353-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2012-5083" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "permissions and access control", "sources": [ { "db": "CNNVD", "id": "CNNVD-201209-293" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.