VAR-201402-0088
Vulnerability from variot - Updated: 2023-12-18 13:44Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. The SESU tool used by several of these products is used to update software on Windows PC systems. Multiple Schneider Electric products are prone to a remote denial-of-service vulnerability. Attackers may exploit this issue to cause an affected application to crash, resulting in a denial-of-service condition. Schneider Electric, StruxureWare SCADA Expert, Vijeo Citect, etc. are the software used by Schneider Electric in France to provide monitoring and control functions in the data acquisition and monitoring system (SCADA)
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201402-0088",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "struxureware scada expert vijeo citect",
"scope": "eq",
"trust": 2.4,
"vendor": "schneider electric",
"version": "7.40"
},
{
"model": "struxureware powerscada expert",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "7.30"
},
{
"model": "citectscada",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "7.20"
},
{
"model": "citectscada",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "7.30"
},
{
"model": "powerlogic scada",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "7.20"
},
{
"model": "struxureware scada expert vijeo citect",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "7.20"
},
{
"model": null,
"scope": "eq",
"trust": 1.0,
"vendor": "citectscada",
"version": "7.20"
},
{
"model": null,
"scope": "eq",
"trust": 1.0,
"vendor": "struxureware scada expert vijeo citect",
"version": "7.20"
},
{
"model": "struxureware scada expert vijeo citect",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "7.30"
},
{
"model": "citectscada",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "7.20 to 7.30sp1"
},
{
"model": "powerlogic scada",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "7.20 to 7.20sr1"
},
{
"model": "struxureware powerscada expert",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "7.30 to 7.30sr1"
},
{
"model": "struxureware scada expert vijeo citect",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "7.20 to 7.30sp1"
},
{
"model": "electric vijeo citect",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "7.x"
},
{
"model": "electric scadapack",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "7.x"
},
{
"model": "electric powerlogic scada",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "7.x"
},
{
"model": "electric struxureware powerscada expert",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "7.x"
},
{
"model": "electric struxureware scada expert vijeo citect",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider",
"version": "7.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "citectscada",
"version": "7.30"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "powerlogic scada",
"version": "7.20"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "struxureware powerscada expert",
"version": "7.30"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "struxureware scada expert vijeo citect",
"version": "7.30"
},
{
"model": "electric vijeo citect",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider",
"version": "7.20"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "struxureware scada expert vijeo citect",
"version": "7.40"
}
],
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "BID",
"id": "65635"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.40:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.30:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_powerscada_expert:7.30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.30:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_powerscada_expert:7.30:sr1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.20:sr1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada:7.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2013-2824"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Carsten Eiram of Risk Based Security",
"sources": [
{
"db": "BID",
"id": "65635"
}
],
"trust": 0.3
},
"cve": "CVE-2013-2824",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 7.8,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2013-2824",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2014-01104",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "3208502c-2352-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-62826",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2013-2824",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2014-01104",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201402-398",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-62826",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "VULHUB",
"id": "VHN-62826"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. The SESU tool used by several of these products is used to update software on Windows PC systems. Multiple Schneider Electric products are prone to a remote denial-of-service vulnerability. \nAttackers may exploit this issue to cause an affected application to crash, resulting in a denial-of-service condition. Schneider Electric, StruxureWare SCADA Expert, Vijeo Citect, etc. are the software used by Schneider Electric in France to provide monitoring and control functions in the data acquisition and monitoring system (SCADA)",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "BID",
"id": "65635"
},
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-62826"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-2824",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-13-350-01",
"trust": 2.5
},
{
"db": "BID",
"id": "65635",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2014-01104",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "57000",
"trust": 0.6
},
{
"db": "IVD",
"id": "3208502C-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-62826",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "VULHUB",
"id": "VHN-62826"
},
{
"db": "BID",
"id": "65635"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"id": "VAR-201402-0088",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "VULHUB",
"id": "VHN-62826"
}
],
"trust": 1.7051020385714284
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
}
]
},
"last_update_date": "2023-12-18T13:44:30.002000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Cumulative update for SCADA Expert Vijeo Citect / CitectSCADA / PowerSCADA Expert",
"trust": 0.8,
"url": "http://www.citect.schneider-electric.com/security-dos"
},
{
"title": "Patch for multiple Schneider Electric products remote denial of service vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/43754"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://ics-cert.us-cert.gov/advisories/icsa-13-350-01"
},
{
"trust": 1.7,
"url": "http://www.citect.schneider-electric.com/security-dos"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-2824"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-2824"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/57000/"
},
{
"trust": 0.6,
"url": "http://download.schneider-electric.com/files?p_doc_ref=sevd%202014-024-02"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "VULHUB",
"id": "VHN-62826"
},
{
"db": "BID",
"id": "65635"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"db": "VULHUB",
"id": "VHN-62826"
},
{
"db": "BID",
"id": "65635"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2014-02-20T00:00:00",
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2014-02-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"date": "2014-02-26T00:00:00",
"db": "VULHUB",
"id": "VHN-62826"
},
{
"date": "2014-02-18T00:00:00",
"db": "BID",
"id": "65635"
},
{
"date": "2014-02-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"date": "2014-02-26T14:55:08.147000",
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"date": "2014-02-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2014-02-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-01104"
},
{
"date": "2014-02-26T00:00:00",
"db": "VULHUB",
"id": "VHN-62826"
},
{
"date": "2014-02-27T10:31:00",
"db": "BID",
"id": "65635"
},
{
"date": "2014-02-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-006085"
},
{
"date": "2014-02-26T16:58:51.330000",
"db": "NVD",
"id": "CVE-2013-2824"
},
{
"date": "2014-02-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Schneider Electric Service disruption in products (DoS) Vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-006085"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "IVD",
"id": "3208502c-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201402-398"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.