VAR-201501-0398

Vulnerability from variot - Updated: 2023-12-18 12:21

Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Attackers can exploit this issue to execute arbitrary code in the context of the affected system. Failed exploit attempts will likely result in denial-of-service conditions. Wonderware InTouch Access Anywhere Server 10.6 and 11.0 are vulnerable; other versions may also be affected. Schneider Electric Wonderware InTouch is an open, scalable HMI and SCADA monitoring solution from Schneider Electric, France, that creates standardized, reusable visualization applications

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201501-0398",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wonderware intouch access anywhere server",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "schneider electric",
        "version": "10.6"
      },
      {
        "model": "wonderware intouch access anywhere server",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "schneider electric",
        "version": "11.0"
      },
      {
        "model": "electric wonderware intouch access anywhere server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "10.6"
      },
      {
        "model": "electric wonderware intouch access anywhere server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "11.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wonderware intouch access anywhere server",
        "version": "10.6"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wonderware intouch access anywhere server",
        "version": "11.0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:wonderware_intouch_access_anywhere_server:10.6:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:wonderware_intouch_access_anywhere_server:11.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "71951"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2014-9190",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2014-9190",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2015-00342",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "aad6dba0-2351-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-77135",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2014-9190",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-00342",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201501-201",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "aad6dba0-2351-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-77135",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. \nAttackers can exploit this issue to execute arbitrary code in the context of the affected system. Failed exploit attempts will likely result in denial-of-service conditions. \nWonderware InTouch Access Anywhere Server 10.6 and 11.0 are vulnerable; other versions may also be affected. Schneider Electric Wonderware InTouch is an open, scalable HMI and SCADA monitoring solution from Schneider Electric, France, that creates standardized, reusable visualization applications",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "BID",
        "id": "71951"
      },
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2014-9190",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-15-008-02",
        "trust": 3.1
      },
      {
        "db": "BID",
        "id": "71951",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "AAD6DBA0-2351-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "db": "BID",
        "id": "71951"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "id": "VAR-201501-0398",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      }
    ],
    "trust": 1.775
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:21:05.159000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Web HMI and Mobile SCADA: Wonderware InTouch Access Anywhere",
        "trust": 0.8,
        "url": "http://software.invensys.com/products/wonderware/hmi-and-supervisory-control/intouch-access-anywhere/"
      },
      {
        "title": "Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/53978"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-008-02"
      },
      {
        "trust": 1.7,
        "url": "https://wdnresource.wonderware.com/support/docs/_securitybulletins/security_bulletin_lfsec00000104.pdf"
      },
      {
        "trust": 1.4,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-9190"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-9190"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/71951/"
      },
      {
        "trust": 0.3,
        "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "db": "BID",
        "id": "71951"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "db": "BID",
        "id": "71951"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-01-15T00:00:00",
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2015-01-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "date": "2015-01-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "date": "2015-01-08T00:00:00",
        "db": "BID",
        "id": "71951"
      },
      {
        "date": "2015-01-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "date": "2015-01-10T02:59:33.693000",
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "date": "2015-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-01-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      },
      {
        "date": "2015-01-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-77135"
      },
      {
        "date": "2015-03-19T08:13:00",
        "db": "BID",
        "id": "71951"
      },
      {
        "date": "2015-01-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2014-007575"
      },
      {
        "date": "2015-01-12T21:34:14.610000",
        "db": "NVD",
        "id": "CVE-2014-9190"
      },
      {
        "date": "2015-01-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-00342"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "aad6dba0-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201501-201"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…