VAR-201501-0403
Vulnerability from variot - Updated: 2023-12-18 12:30The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. Schneider Electric ETG3000 FactoryCast HMI Gateway is a new intelligent web gateway. This BID is being retired as a duplicate of BID 72258. This may aid in further attacks. This vulnerability stems from the lack of an effective trust management mechanism in network systems or products. Attackers can use default passwords or hard-coded passwords, hard-coded certificates, etc. to attack affected components
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201501-0403",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tsxetg3022",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3021",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3010",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3000",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric etg3000 factorycast hmi gateway",
"scope": null,
"trust": 1.2,
"vendor": "schneider",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway",
"scope": "eq",
"trust": 1.2,
"vendor": "schneider electric",
"version": "1.60.4"
},
{
"model": "etg3000 factorycast hmi gateway",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "1.60.4"
},
{
"model": "etg3000 factorycast hmi gateway",
"scope": "lt",
"trust": 0.8,
"vendor": "schneider electric",
"version": "1.60 ir 04"
},
{
"model": "tsxetg3000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3010",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3021",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "tsxetg3022",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3022",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3021",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3010",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway tsxetg3000",
"scope": null,
"trust": 0.3,
"vendor": "schneider electric",
"version": null
},
{
"model": "etg3000 factorycast hmi gateway ir",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "1.6004"
},
{
"model": "factorycast hmi gateway",
"scope": "eq",
"trust": 0.2,
"vendor": "etg3000",
"version": "3.12"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3021",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3000",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "etg3000 factorycast hmi gateway",
"version": "1.60.4"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3022",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "tsxetg3010",
"version": null
}
],
"sources": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:etg3000_factorycast_hmi_gateway_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.60.4",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3010:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3021:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:tsxetg3022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2014-9198"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Unknown,Narendra Shinde of Qualys Security",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
}
],
"trust": 0.6
},
"cve": "CVE-2014-9198",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2014-9198",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-00498",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-00647",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "a629a808-2351-11e6-abef-000c29c66e3d",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-77143",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2014-9198",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2015-00498",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2015-00647",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201501-613",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201501-634",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-77143",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "VULHUB",
"id": "VHN-77143"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. Schneider Electric ETG3000 FactoryCast HMI Gateway is a new intelligent web gateway. This BID is being retired as a duplicate of BID 72258. This may aid in further attacks. This vulnerability stems from the lack of an effective trust management mechanism in network systems or products. Attackers can use default passwords or hard-coded passwords, hard-coded certificates, etc. to attack affected components",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
},
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-77143"
}
],
"trust": 3.69
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-9198",
"trust": 4.7
},
{
"db": "ICS CERT",
"id": "ICSA-15-020-02",
"trust": 4.3
},
{
"db": "BID",
"id": "72258",
"trust": 2.6
},
{
"db": "BID",
"id": "77765",
"trust": 2.0
},
{
"db": "CNNVD",
"id": "CNNVD-201501-613",
"trust": 1.1
},
{
"db": "CNVD",
"id": "CNVD-2015-00647",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2015-00498",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634",
"trust": 0.7
},
{
"db": "IVD",
"id": "1D9BBECC-1E97-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "IVD",
"id": "A629A808-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-77143",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "VULHUB",
"id": "VHN-77143"
},
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"id": "VAR-201501-0403",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "VULHUB",
"id": "VHN-77143"
}
],
"trust": 2.5181818
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 1.2
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.4
}
],
"sources": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
}
]
},
"last_update_date": "2023-12-18T12:30:28.046000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "TSX ETG 30xx V1.60 IR04",
"trust": 0.8,
"url": "http://www.schneider-electric.com/download/ww/en/details/681790255-tsxetg30xx-v160-ir4/?showasiframe=true\u0026amp;reference=etg30xxv160-ir04"
},
{
"title": "Schneider Electric ETG3000 FactoryCast HMI Gateway FTP built-in password vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/54452"
},
{
"title": "Schneider Electric ETG3000 FactoryCast HMI Gateway verifies patches for bypassing vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/54278"
},
{
"title": "ETG30xx_V1.60.4_UpgradeFw",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=53568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-255",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-77143"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 4.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-020-02"
},
{
"trust": 2.3,
"url": "http://www.securityfocus.com/bid/72258"
},
{
"trust": 2.3,
"url": "http://www.securityfocus.com/bid/77765"
},
{
"trust": 1.4,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-9198"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-9198"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "VULHUB",
"id": "VHN-77143"
},
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"db": "VULHUB",
"id": "VHN-77143"
},
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-01-27T00:00:00",
"db": "IVD",
"id": "1d9bbecc-1e97-11e6-abef-000c29c66e3d"
},
{
"date": "2015-01-23T00:00:00",
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-01-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"date": "2015-01-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"date": "2015-01-27T00:00:00",
"db": "VULHUB",
"id": "VHN-77143"
},
{
"date": "2015-01-27T00:00:00",
"db": "BID",
"id": "77765"
},
{
"date": "2015-01-21T00:00:00",
"db": "BID",
"id": "72258"
},
{
"date": "2015-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"date": "2015-01-27T19:59:10.810000",
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"date": "2015-01-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"date": "2015-01-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-01-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00498"
},
{
"date": "2015-01-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-00647"
},
{
"date": "2019-04-15T00:00:00",
"db": "VULHUB",
"id": "VHN-77143"
},
{
"date": "2019-04-12T18:00:00",
"db": "BID",
"id": "77765"
},
{
"date": "2019-04-12T19:00:00",
"db": "BID",
"id": "72258"
},
{
"date": "2015-01-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007804"
},
{
"date": "2019-04-15T12:30:07.633000",
"db": "NVD",
"id": "CVE-2014-9198"
},
{
"date": "2019-04-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-613"
},
{
"date": "2021-09-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201501-634"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "network",
"sources": [
{
"db": "BID",
"id": "77765"
},
{
"db": "BID",
"id": "72258"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric ETG3000 FactoryCast HMI Gateway FTP Built-in password vulnerability",
"sources": [
{
"db": "IVD",
"id": "a629a808-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-00498"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201501-613"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…