VAR-201507-0390

Vulnerability from variot - Updated: 2023-12-18 12:51

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors. Multiple Hospira products are prone to a local security-bypass vulnerability. Successful exploits will allow local attackers to bypass certain security restrictions. Other attacks are also possible. The following products are available: Plum A+ Infusion System 13.4 and prior Plum A+3 Infusion System 13.6 and prior Symbiq Infusion System 3.13 and prior. Hospira LifeCare PCA Infusion System is an intelligent infusion system developed by Hospira in the United States. A security vulnerability exists in Hospira LifeCare PCA Infusion System prior to version 7.0. The vulnerability stems from the program incorrectly storing private keys and certificates. A remote attacker could exploit this vulnerability to modify drug doses

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201507-0390",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "lifecare pca3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pcainfusion",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "hospira",
        "version": "5.0"
      },
      {
        "model": "lifecare pca5",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pca infusion system",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "hospira",
        "version": "7.0"
      },
      {
        "model": "lifecare pca3",
        "scope": null,
        "trust": 0.8,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pca5",
        "scope": null,
        "trust": 0.8,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pcainfusion",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "hospira",
        "version": "5.0"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:hospira:lifecare_pcainfusion_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:hospira:lifecare_pca5:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:hospira:lifecare_pca3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios",
    "sources": [
      {
        "db": "BID",
        "id": "75136"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2015-3957",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Local",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 4.6,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2015-3957",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-81918",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2015-3957",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201506-434",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-81918",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors. Multiple Hospira products are prone to a local security-bypass vulnerability. \nSuccessful exploits will allow local attackers to bypass certain security restrictions. Other attacks are also possible. \nThe following products are available:\nPlum A+ Infusion System 13.4 and prior\nPlum A+3 Infusion System 13.6 and prior\nSymbiq Infusion System 3.13 and prior. Hospira LifeCare PCA Infusion System is an intelligent infusion system developed by Hospira in the United States. A security vulnerability exists in Hospira LifeCare PCA Infusion System prior to version 7.0. The vulnerability stems from the program incorrectly storing private keys and certificates. A remote attacker could exploit this vulnerability to modify drug doses",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "BID",
        "id": "75136"
      },
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-3957",
        "trust": 2.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-15-125-01B",
        "trust": 2.5
      },
      {
        "db": "BID",
        "id": "75136",
        "trust": 2.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-81918",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "db": "BID",
        "id": "75136"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "id": "VAR-201507-0390",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T12:51:41.727000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "LifeCare PCA Infusion System",
        "trust": 0.8,
        "url": "http://www.hospira.com/en/products_and_services/infusion_pumps/lifecare/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-255",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://www.fda.gov/medicaldevices/safety/alertsandnotices/ucm446809.htm"
      },
      {
        "trust": 2.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-125-01b"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/75136"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-3957"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-3957"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "db": "BID",
        "id": "75136"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-07-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "date": "2015-06-10T00:00:00",
        "db": "BID",
        "id": "75136"
      },
      {
        "date": "2015-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "date": "2015-07-06T19:59:03.487000",
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "date": "2015-06-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-12-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-81918"
      },
      {
        "date": "2015-07-15T00:29:00",
        "db": "BID",
        "id": "75136"
      },
      {
        "date": "2015-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      },
      {
        "date": "2016-12-06T03:01:32.790000",
        "db": "NVD",
        "id": "CVE-2015-3957"
      },
      {
        "date": "2015-07-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "BID",
        "id": "75136"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ],
    "trust": 0.9
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hospira LifeCare PCA Infusion System Vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003459"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-434"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…