VAR-201507-0391

Vulnerability from variot - Updated: 2023-12-18 12:51

Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service (forced manual reboot) via a flood of TCP packets. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. Multiple Hospira products are prone to a remote denial-of-service vulnerability. An attacker can exploit this issue to cause a denial-of-service condition. Hospira LifeCare PCA Infusion System is an intelligent infusion system developed by Hospira in the United States. A security vulnerability exists in Hospira LifeCare PCA Infusion System 5.0 and earlier

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201507-0391",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "lifecare pcainfusion",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "hospira",
        "version": "5.0"
      },
      {
        "model": "lifecare pca infusion system",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "hospira",
        "version": "5.0"
      },
      {
        "model": "lifecare pca3",
        "scope": null,
        "trust": 0.8,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pca5",
        "scope": null,
        "trust": 0.8,
        "vendor": "hospira",
        "version": null
      },
      {
        "model": "lifecare pcainfusion",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "hospira",
        "version": "5.0"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:hospira:lifecare_pcainfusion_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:hospira:lifecare_pca5:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:hospira:lifecare_pca3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios",
    "sources": [
      {
        "db": "BID",
        "id": "75138"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2015-3958",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2015-3958",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-81919",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2015-3958",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201506-435",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-81919",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service (forced manual reboot) via a flood of TCP packets. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. Multiple Hospira products are prone to a remote denial-of-service vulnerability. \nAn attacker can exploit this issue to cause a denial-of-service condition. Hospira LifeCare PCA Infusion System is an intelligent infusion system developed by Hospira in the United States. A security vulnerability exists in Hospira LifeCare PCA Infusion System 5.0 and earlier",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "BID",
        "id": "75138"
      },
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-3958",
        "trust": 2.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-15-125-01B",
        "trust": 2.5
      },
      {
        "db": "BID",
        "id": "75138",
        "trust": 2.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-81919",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "db": "BID",
        "id": "75138"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "id": "VAR-201507-0391",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2023-12-18T12:51:41.756000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "LifeCare PCA Infusion System",
        "trust": 0.8,
        "url": "http://www.hospira.com/en/products_and_services/infusion_pumps/lifecare/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-19",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://www.fda.gov/medicaldevices/safety/alertsandnotices/ucm446809.htm"
      },
      {
        "trust": 2.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-125-01b"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/75138"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-3958"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-3958"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "db": "BID",
        "id": "75138"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-07-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "date": "2015-06-11T00:00:00",
        "db": "BID",
        "id": "75138"
      },
      {
        "date": "2015-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "date": "2015-07-06T19:59:04.363000",
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "date": "2015-06-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-12-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-81919"
      },
      {
        "date": "2015-07-15T00:29:00",
        "db": "BID",
        "id": "75138"
      },
      {
        "date": "2015-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      },
      {
        "date": "2016-12-06T03:01:33.917000",
        "db": "NVD",
        "id": "CVE-2015-3958"
      },
      {
        "date": "2015-07-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-435"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hospira LifeCare PCA Infusion System Service disruption in  (DoS) Vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003458"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Failure to Handle Exceptional Conditions",
    "sources": [
      {
        "db": "BID",
        "id": "75138"
      }
    ],
    "trust": 0.3
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…