VAR-201510-0199

Vulnerability from variot - Updated: 2023-12-18 12:51

Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors. Allen-Bradley MicroLogix 1100 and 1400 The device includes FRAME A vulnerability exists in which the contents of an arbitrary file are inserted into an element. Supplementary information : CWE Vulnerability type by CWE-434: Unrestricted Upload of File with Dangerous Type ( Unlimited upload of dangerous types of files ) Has been identified. http://cwe.mitre.org/data/definitions/434.htmlBy a remotely authenticated user FRAME Any file content may be inserted into the element. The Allen-Bradley MicroLogix 1100 has a file insertion vulnerability in versions prior to B FRN 15.000 and versions prior to 1400 in B FRN 15.003. Rockwell Automation 1766-L32 Series is a 1766-L32 series programmable logic controller (PLC) from Rockwell Automation. A remote file inclusion vulnerability exists in the Rockwell Automation 1766-L32 Series product, which is caused by the program's insufficient filtering of user-submitted input. An attacker could use this vulnerability to obtain sensitive information or execute arbitrary script code in the context of a Web process to control the application. This may allow the attacker to compromise the application; other attacks are also possible

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201510-0199",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "micrologix 1400",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "15.002"
      },
      {
        "model": "micrologix 1100",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "14.000"
      },
      {
        "model": "micrologix 1100",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "b frn 15.000"
      },
      {
        "model": "micrologix 1400",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": "b frn 15.003"
      },
      {
        "model": "automation micrologix",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1100"
      },
      {
        "model": "automation micrologix",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400"
      },
      {
        "model": "micrologix 1100",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "14.000"
      },
      {
        "model": "micrologix 1400",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "15.002"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "micrologix 1100",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "micrologix 1400",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "15.002",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "14.000",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ICS-CERT",
    "sources": [
      {
        "db": "BID",
        "id": "76357"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2015-6491",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2015-6491",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2015-07305",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "7c716140-2351-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.0,
            "id": "VHN-84452",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2015-6491",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-07305",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201510-675",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "7c716140-2351-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-84452",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors. Allen-Bradley MicroLogix 1100 and 1400 The device includes FRAME A vulnerability exists in which the contents of an arbitrary file are inserted into an element. Supplementary information : CWE Vulnerability type by CWE-434: Unrestricted Upload of File with Dangerous Type ( Unlimited upload of dangerous types of files ) Has been identified. http://cwe.mitre.org/data/definitions/434.htmlBy a remotely authenticated user FRAME Any file content may be inserted into the element. The Allen-Bradley MicroLogix 1100 has a file insertion vulnerability in versions prior to B FRN 15.000 and versions prior to 1400 in B FRN 15.003. Rockwell Automation 1766-L32 Series is a 1766-L32 series programmable logic controller (PLC) from Rockwell Automation. \nA remote file inclusion vulnerability exists in the Rockwell Automation 1766-L32 Series product, which is caused by the program\u0027s insufficient filtering of user-submitted input. An attacker could use this vulnerability to obtain sensitive information or execute arbitrary script code in the context of a Web process to control the application. This may allow the attacker to compromise  the application; other attacks are also possible",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "db": "BID",
        "id": "76357"
      },
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      }
    ],
    "trust": 3.24
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-6491",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-15-300-03",
        "trust": 3.1
      },
      {
        "db": "BID",
        "id": "76357",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "7C716140-2351-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "db": "BID",
        "id": "76357"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "id": "VAR-201510-0199",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      }
    ],
    "trust": 1.7076923000000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:51:50.998000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "MicroLogix\u30b7\u30b9\u30c6\u30e0",
        "trust": 0.8,
        "url": "http://ab.rockwellautomation.com/ja/programmable-controllers/micrologix-systems"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-300-03"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-6491"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-6491"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/76357"
      },
      {
        "trust": 0.3,
        "url": "http://www.rockwellautomation.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "db": "BID",
        "id": "76357"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "db": "BID",
        "id": "76357"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-11-05T00:00:00",
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2015-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "date": "2015-10-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "date": "2015-08-13T00:00:00",
        "db": "BID",
        "id": "76357"
      },
      {
        "date": "2015-10-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "date": "2015-10-28T10:59:13.887000",
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "date": "2015-08-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "date": "2015-10-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-11-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      },
      {
        "date": "2015-10-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-84452"
      },
      {
        "date": "2015-12-08T22:02:00",
        "db": "BID",
        "id": "76357"
      },
      {
        "date": "2015-10-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-005656"
      },
      {
        "date": "2015-10-28T21:03:25.697000",
        "db": "NVD",
        "id": "CVE-2015-6491"
      },
      {
        "date": "2015-08-19T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "date": "2015-10-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201508-365"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ],
    "trust": 1.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Allen-Bradley MicroLogix Arbitrary file insertion vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-07305"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "IVD",
        "id": "7c716140-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201510-675"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…