var-201609-0306
Vulnerability from variot
Session fixation vulnerability in Cisco Firepower Management Center and Cisco FireSIGHT System Software through 6.1.0 allows remote attackers to hijack web sessions via a session identifier, aka Bug ID CSCuz80503. Vendors have confirmed this vulnerability Bug ID CSCuz80503 It is released as.Session by a third party ID Through Web Sessions may be hijacked. An attacker can exploit this issue to hijack an arbitrary session and gain unauthorized access to the affected application. This issue is being tracked by Cisco Bug ID CSCuz8050
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201609-0306", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "firesight system software", "scope": "eq", "trust": 1.9, "vendor": "cisco", "version": "6.1.0" }, { "model": "firesight system software", "scope": "eq", "trust": 1.9, "vendor": "cisco", "version": "6.0.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.9, "vendor": "cisco", "version": "5.4.0.2" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.3.0.4" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.3.0.6" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.4.0.5" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.3.0.7" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.3.0.5" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.3.0.3" }, { "model": "firesight system software", "scope": "eq", "trust": 1.6, "vendor": "cisco", "version": "5.4.0.3" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.3.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "6.0.0" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.4.1.2" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.4.0.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.3.1.4" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.3.1.3" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.3.1.2" }, { "model": "firesight system software", "scope": "eq", "trust": 1.3, "vendor": "cisco", "version": "5.3.1.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.0" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.0.4" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.3.0.2" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.3.1.7" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.8" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.3.0" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.0.6" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.1.3" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.4" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.3" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.6" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.3.0.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.5" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.3.1.5" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "6.0.0.1" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.4.1.4" }, { "model": "firesight system software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "5.2.0.2" }, { "model": "firepower management center", "scope": "lte", "trust": 0.8, "vendor": "cisco", "version": "6.1.0" }, { "model": "firesight system software", "scope": "lte", "trust": 0.8, "vendor": "cisco", "version": "6.1.0" }, { "model": "firesight system software", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.4" }, { "model": "firesight system software", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3" }, { "model": "firesight system software", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "6.0" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "6.1" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "6.0.1" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "6.0" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.4.1" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.4" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3.1" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.2" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "4.10.3" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.4.1.3" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.4.0.1" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3.1.2" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3.0.4" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3.0.3" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.3.0.2" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "5.0" }, { "model": "firepower management center", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "4.10.3.9" } ], "sources": [ { "db": "BID", "id": "92825" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:6.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.1.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.1.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.1.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:6.0.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:6.0.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:6.1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.2.0.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.1.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.4.0.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:firesight_system_software:5.3.0.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2016-6394" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vendor reported this issue.", "sources": [ { "db": "BID", "id": "92825" } ], "trust": 0.3 }, "cve": "CVE-2016-6394", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2016-6394", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-95214", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2016-6394", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2016-6394", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-201609-108", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-95214", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-95214" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Session fixation vulnerability in Cisco Firepower Management Center and Cisco FireSIGHT System Software through 6.1.0 allows remote attackers to hijack web sessions via a session identifier, aka Bug ID CSCuz80503. Vendors have confirmed this vulnerability Bug ID CSCuz80503 It is released as.Session by a third party ID Through Web Sessions may be hijacked. \nAn attacker can exploit this issue to hijack an arbitrary session and gain unauthorized access to the affected application. \nThis issue is being tracked by Cisco Bug ID CSCuz8050", "sources": [ { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "BID", "id": "92825" }, { "db": "VULHUB", "id": "VHN-95214" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-6394", "trust": 2.8 }, { "db": "BID", "id": "92825", "trust": 2.0 }, { "db": "SECTRACK", "id": "1036757", "trust": 1.1 }, { "db": "JVNDB", "id": "JVNDB-2016-004635", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201609-108", "trust": 0.7 }, { "db": "NSFOCUS", "id": "34782", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-95214", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-95214" }, { "db": "BID", "id": "92825" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "id": "VAR-201609-0306", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-95214" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T12:29:55.596000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20160907-fsmc", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20160907-fsmc" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-004635" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-264", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-95214" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "http://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20160907-fsmc" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/92825" }, { "trust": 1.1, "url": "http://www.securitytracker.com/id/1036757" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-6394" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-6394" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/34782" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-95214" }, { "db": "BID", "id": "92825" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-95214" }, { "db": "BID", "id": "92825" }, { "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "db": "NVD", "id": "CVE-2016-6394" }, { "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-09-12T00:00:00", "db": "VULHUB", "id": "VHN-95214" }, { "date": "2016-09-07T00:00:00", "db": "BID", "id": "92825" }, { "date": "2016-09-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "date": "2016-09-12T10:59:07.287000", "db": "NVD", "id": "CVE-2016-6394" }, { "date": "2016-09-08T00:00:00", "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-11-28T00:00:00", "db": "VULHUB", "id": "VHN-95214" }, { "date": "2016-09-07T00:00:00", "db": "BID", "id": "92825" }, { "date": "2016-09-14T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-004635" }, { "date": "2016-11-28T20:32:06.837000", "db": "NVD", "id": "CVE-2016-6394" }, { "date": "2016-09-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201609-108" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201609-108" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Firepower Management Center and FireSIGHT system In software Web Session hijacking vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-004635" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "permissions and access control", "sources": [ { "db": "CNNVD", "id": "CNNVD-201609-108" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.