var-201807-0327
Vulnerability from variot

AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process. AVEVA InTouch 2014 and InTouch 2017 Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. AVEVA InTouch is an embedded HMI software package from AVEVA Group plc, UK. The product provides read, write tag and event monitoring for HMI clients. There is a security hole in AVEVA InTouch. AVEVA InTouch is prone to a stack-based buffer-overflow vulnerability because it fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely cause a denial-of-service condition

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201807-0327",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "intouch 2014",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "aveva",
        "version": "r2"
      },
      {
        "model": "intouch 2017",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "aveva",
        "version": null
      },
      {
        "model": "intouch 2014",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "aveva",
        "version": "r2 sp1"
      },
      {
        "model": "intouch 2017",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "aveva",
        "version": "none"
      },
      {
        "model": "intouch 2017",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "aveva",
        "version": "update 1"
      },
      {
        "model": "intouch 2017",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "aveva",
        "version": "update 2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "intouch 2017",
        "version": null
      },
      {
        "model": "intouch r2 sp1",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "aveva",
        "version": "\u003c=2014"
      },
      {
        "model": "intouch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "aveva",
        "version": "2017"
      },
      {
        "model": "intouch update",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "aveva",
        "version": "20171"
      },
      {
        "model": "intouch update",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "aveva",
        "version": "20172"
      },
      {
        "model": "r2",
        "scope": null,
        "trust": 0.4,
        "vendor": "intouch 2014",
        "version": null
      },
      {
        "model": "aveva intouch update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "20172"
      },
      {
        "model": "aveva intouch update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "20171"
      },
      {
        "model": "aveva intouch",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "2017"
      },
      {
        "model": "aveva intouch r2 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "2014"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "BID",
        "id": "104864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:update_1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:update_2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:aveva:intouch_2014:r2:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:aveva:intouch_2014:r2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "George Lashenko of CyberX.",
    "sources": [
      {
        "db": "BID",
        "id": "104864"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-10628",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2018-10628",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-14205",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "7d859062-463f-11e9-b3d3-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-10628",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-10628",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-14205",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201807-1792",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "7d859062-463f-11e9-b3d3-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process. AVEVA InTouch 2014 and InTouch 2017 Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. AVEVA InTouch is an embedded HMI software package from AVEVA Group plc, UK. The product provides read, write tag and event monitoring for HMI clients. There is a security hole in AVEVA InTouch. AVEVA InTouch is prone to a stack-based buffer-overflow vulnerability because it fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely cause a denial-of-service condition",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "BID",
        "id": "104864"
      },
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      }
    ],
    "trust": 2.61
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-10628",
        "trust": 3.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-200-02",
        "trust": 2.7
      },
      {
        "db": "BID",
        "id": "104864",
        "trust": 2.5
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "7D859062-463F-11E9-B3D3-000C29342CB1",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "BID",
        "id": "104864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "id": "VAR-201807-0327",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      }
    ],
    "trust": 1.5430555566666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:44:00.267000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "AVEVA Security Bulletin LFSEC0000127",
        "trust": 0.8,
        "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127(003).pdf"
      },
      {
        "title": "Patch for AVEVA InTouch Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/135579"
      },
      {
        "title": "AVEVA InTouch Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82586"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-200-02"
      },
      {
        "trust": 1.6,
        "url": "http://www.securityfocus.com/bid/104864"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10628"
      },
      {
        "trust": 1.0,
        "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127%28003%29.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10628"
      },
      {
        "trust": 0.6,
        "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127(003).pdf"
      },
      {
        "trust": 0.3,
        "url": "http://www.schneider-electric.com/products/ww/en/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "BID",
        "id": "104864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "db": "BID",
        "id": "104864"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-07-30T00:00:00",
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "date": "2018-07-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "date": "2018-07-19T00:00:00",
        "db": "BID",
        "id": "104864"
      },
      {
        "date": "2018-11-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "date": "2018-07-24T18:29:00.233000",
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "date": "2018-07-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-01-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      },
      {
        "date": "2018-07-19T00:00:00",
        "db": "BID",
        "id": "104864"
      },
      {
        "date": "2018-11-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-008931"
      },
      {
        "date": "2023-11-07T02:51:31.013000",
        "db": "NVD",
        "id": "CVE-2018-10628"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "AVEVA InTouch Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-14205"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer error",
    "sources": [
      {
        "db": "IVD",
        "id": "7d859062-463f-11e9-b3d3-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201807-1792"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.