var-201807-0327
Vulnerability from variot
AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process. AVEVA InTouch 2014 and InTouch 2017 Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. AVEVA InTouch is an embedded HMI software package from AVEVA Group plc, UK. The product provides read, write tag and event monitoring for HMI clients. There is a security hole in AVEVA InTouch. AVEVA InTouch is prone to a stack-based buffer-overflow vulnerability because it fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely cause a denial-of-service condition
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201807-0327", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "intouch 2014", "scope": "eq", "trust": 1.6, "vendor": "aveva", "version": "r2" }, { "model": "intouch 2017", "scope": "eq", "trust": 1.6, "vendor": "aveva", "version": null }, { "model": "intouch 2014", "scope": "lte", "trust": 0.8, "vendor": "aveva", "version": "r2 sp1" }, { "model": "intouch 2017", "scope": "eq", "trust": 0.8, "vendor": "aveva", "version": "none" }, { "model": "intouch 2017", "scope": "eq", "trust": 0.8, "vendor": "aveva", "version": "update 1" }, { "model": "intouch 2017", "scope": "eq", "trust": 0.8, "vendor": "aveva", "version": "update 2" }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "intouch 2017", "version": null }, { "model": "intouch r2 sp1", "scope": "lte", "trust": 0.6, "vendor": "aveva", "version": "\u003c=2014" }, { "model": "intouch", "scope": "eq", "trust": 0.6, "vendor": "aveva", "version": "2017" }, { "model": "intouch update", "scope": "eq", "trust": 0.6, "vendor": "aveva", "version": "20171" }, { "model": "intouch update", "scope": "eq", "trust": 0.6, "vendor": "aveva", "version": "20172" }, { "model": "r2", "scope": null, "trust": 0.4, "vendor": "intouch 2014", "version": null }, { "model": "aveva intouch update", "scope": "eq", "trust": 0.3, "vendor": "schneider electric", "version": "20172" }, { "model": "aveva intouch update", "scope": "eq", "trust": 0.3, "vendor": "schneider electric", "version": "20171" }, { "model": "aveva intouch", "scope": "eq", "trust": 0.3, "vendor": "schneider electric", "version": "2017" }, { "model": "aveva intouch r2 sp1", "scope": "eq", "trust": 0.3, "vendor": "schneider electric", "version": "2014" } ], "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "BID", "id": "104864" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:update_1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:update_2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:aveva:intouch_2014:r2:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:aveva:intouch_2017:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:aveva:intouch_2014:r2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-10628" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "George Lashenko of CyberX.", "sources": [ { "db": "BID", "id": "104864" } ], "trust": 0.3 }, "cve": "CVE-2018-10628", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2018-10628", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-14205", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "7d859062-463f-11e9-b3d3-000c29342cb1", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-10628", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-10628", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2018-14205", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201807-1792", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1", "trust": 0.2, "value": "CRITICAL" } ] } ], "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process. AVEVA InTouch 2014 and InTouch 2017 Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. AVEVA InTouch is an embedded HMI software package from AVEVA Group plc, UK. The product provides read, write tag and event monitoring for HMI clients. There is a security hole in AVEVA InTouch. AVEVA InTouch is prone to a stack-based buffer-overflow vulnerability because it fails to properly bounds-check user-supplied data before copying it into an insufficiently sized buffer. Failed exploit attempts will likely cause a denial-of-service condition", "sources": [ { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "BID", "id": "104864" }, { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" } ], "trust": 2.61 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-10628", "trust": 3.5 }, { "db": "ICS CERT", "id": "ICSA-18-200-02", "trust": 2.7 }, { "db": "BID", "id": "104864", "trust": 2.5 }, { "db": "CNVD", "id": "CNVD-2018-14205", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201807-1792", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-008931", "trust": 0.8 }, { "db": "IVD", "id": "7D859062-463F-11E9-B3D3-000C29342CB1", "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "BID", "id": "104864" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "id": "VAR-201807-0327", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" } ], "trust": 1.5430555566666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" } ] }, "last_update_date": "2023-12-18T12:44:00.267000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "AVEVA Security Bulletin LFSEC0000127", "trust": 0.8, "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127(003).pdf" }, { "title": "Patch for AVEVA InTouch Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/135579" }, { "title": "AVEVA InTouch Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82586" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-119", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.7, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-200-02" }, { "trust": 1.6, "url": "http://www.securityfocus.com/bid/104864" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10628" }, { "trust": 1.0, "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127%28003%29.pdf" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10628" }, { "trust": 0.6, "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/securitybulletin_lfsec127(003).pdf" }, { "trust": 0.3, "url": "http://www.schneider-electric.com/products/ww/en/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "BID", "id": "104864" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" }, { "db": "BID", "id": "104864" }, { "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "db": "NVD", "id": "CVE-2018-10628" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-07-30T00:00:00", "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "date": "2018-07-30T00:00:00", "db": "CNVD", "id": "CNVD-2018-14205" }, { "date": "2018-07-19T00:00:00", "db": "BID", "id": "104864" }, { "date": "2018-11-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "date": "2018-07-24T18:29:00.233000", "db": "NVD", "id": "CVE-2018-10628" }, { "date": "2018-07-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-01-23T00:00:00", "db": "CNVD", "id": "CNVD-2018-14205" }, { "date": "2018-07-19T00:00:00", "db": "BID", "id": "104864" }, { "date": "2018-11-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008931" }, { "date": "2023-11-07T02:51:31.013000", "db": "NVD", "id": "CVE-2018-10628" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1792" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1792" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "AVEVA InTouch Buffer Overflow Vulnerability", "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-14205" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Buffer error", "sources": [ { "db": "IVD", "id": "7d859062-463f-11e9-b3d3-000c29342cb1" }, { "db": "CNNVD", "id": "CNNVD-201807-1792" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.