VAR-201808-0079
Vulnerability from variot - Updated: 2023-12-18 13:28An exploitable buffer overflow vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly handles the URL parameter during a firmware update request, leading to a buffer overflow on a global section. An attacker can send an HTTP GET request to trigger this vulnerability. Insteon Hub Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Insteon Hub is an Insteon central controller product of Insteon Company in the United States. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0079",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hub",
"scope": "eq",
"trust": 2.4,
"vendor": "insteon",
"version": "1012"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:insteon:hub:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14444"
}
]
},
"cve": "CVE-2017-14444",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 8.5,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 8.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2017-14444",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 8.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-105167",
"impactScore": 8.5,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.1,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "talos-cna@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.9,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-14444",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-14444",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2017-14444",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201709-624",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-105167",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2017-14444",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An exploitable buffer overflow vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly handles the URL parameter during a firmware update request, leading to a buffer overflow on a global section. An attacker can send an HTTP GET request to trigger this vulnerability. Insteon Hub Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Insteon Hub is an Insteon central controller product of Insteon Company in the United States. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "VULMON",
"id": "CVE-2017-14444"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "TALOS",
"id": "TALOS-2017-0493",
"trust": 2.6
},
{
"db": "NVD",
"id": "CVE-2017-14444",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624",
"trust": 0.7
},
{
"db": "SEEBUG",
"id": "SSVID-97356",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-105167",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2017-14444",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"id": "VAR-201808-0079",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-105167"
}
],
"trust": 0.7825397
},
"last_update_date": "2023-12-18T13:28:49.268000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.insteon.com/"
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2017-14444 "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://www.talosintelligence.com/vulnerability_reports/talos-2017-0493"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-14444"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-14444"
},
{
"trust": 0.6,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2017-0493"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2017-14444"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-105167"
},
{
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-02T00:00:00",
"db": "VULHUB",
"id": "VHN-105167"
},
{
"date": "2018-08-02T00:00:00",
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"date": "2018-10-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"date": "2018-08-02T19:29:00.233000",
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"date": "2017-09-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-14T00:00:00",
"db": "VULHUB",
"id": "VHN-105167"
},
{
"date": "2022-12-14T00:00:00",
"db": "VULMON",
"id": "CVE-2017-14444"
},
{
"date": "2018-10-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"date": "2022-12-14T16:15:23.177000",
"db": "NVD",
"id": "CVE-2017-14444"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Insteon Hub Buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014115"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-624"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…