VAR-201808-0145
Vulnerability from variot - Updated: 2023-12-18 12:01Specially crafted commands sent through the PubNub service in Insteon Hub 2245-222 with firmware version 1012 can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability.At 0x9d014cc0 the value for the cmd key is copied using strcpy to the buffer at $sp+0x11c. This buffer is 20 bytes large, sending anything longer will cause a buffer overflow. Insteon Hub 2245-222 Contains a buffer error vulnerability.Information may be tampered with. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. Insteon Hub is an Insteon central controller product of Insteon Company in the United States
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0145",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hub",
"scope": "eq",
"trust": 2.4,
"vendor": "insteon",
"version": "1012"
},
{
"model": "hub",
"scope": "eq",
"trust": 0.6,
"vendor": "insteon",
"version": "2245-222"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:insteon:hub_firmware:1012:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-16252"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Discovered by Claudio Bozzato of Cisco Talos.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
],
"trust": 0.6
},
"cve": "CVE-2017-16252",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.5,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-16252",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-16483",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-107156",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "talos-cna@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-16252",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-16252",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2017-16252",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-16252",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2018-16483",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201711-174",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-107156",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Specially crafted commands sent through the PubNub service in Insteon Hub 2245-222 with firmware version 1012 can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability.At 0x9d014cc0 the value for the cmd key is copied using strcpy to the buffer at $sp+0x11c. This buffer is 20 bytes large, sending anything longer will cause a buffer overflow. Insteon Hub 2245-222 Contains a buffer error vulnerability.Information may be tampered with. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. Insteon Hub is an Insteon central controller product of Insteon Company in the United States",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-16252",
"trust": 3.1
},
{
"db": "TALOS",
"id": "TALOS-2017-0483",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2018-16483",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-107156",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"id": "VAR-201808-0145",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
}
],
"trust": 1.3825397
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": "Gateway / Hub: Open Ecosystem",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
}
]
},
"last_update_date": "2023-12-18T12:01:25.008000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.insteon.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-107156"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.talosintelligence.com/vulnerability_reports/talos-2017-0483"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-16252"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16252"
},
{
"trust": 0.6,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2017-0483"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"db": "VULHUB",
"id": "VHN-107156"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"date": "2018-08-06T00:00:00",
"db": "VULHUB",
"id": "VHN-107156"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"date": "2018-08-06T21:29:00.237000",
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"date": "2017-10-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-16483"
},
{
"date": "2022-12-09T00:00:00",
"db": "VULHUB",
"id": "VHN-107156"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014192"
},
{
"date": "2022-12-09T02:35:11.243000",
"db": "NVD",
"id": "CVE-2017-16252"
},
{
"date": "2022-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Insteon Hub 2245-222 Buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014192"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201711-174"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.