VAR-201808-0157

Vulnerability from variot - Updated: 2023-12-18 13:56

An exploitable denial of service vulnerability exists in Insteon Hub running firmware version 1012. Leftover demo functionality allows for arbitrarily rebooting the device without authentication. An attacker can send a UDP packet to trigger this vulnerability. Insteon Hub There are authentication vulnerabilities in the firmware.Service operation interruption (DoS) There is a possibility of being put into a state. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. Insteon Hub is an Insteon central controller product of Insteon Company in the United States

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201808-0157",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "hub",
        "scope": "eq",
        "trust": 3.0,
        "vendor": "insteon",
        "version": "1012"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:insteon:insteon_hub_firmware:1012:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:insteon:insteon_hub:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      }
    ]
  },
  "cve": "CVE-2017-16348",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-16348",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-16874",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-107261",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "talos-cna@cisco.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2017-16348",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2017-16348",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2017-16348",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-16874",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201808-777",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107261",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable denial of service vulnerability exists in Insteon Hub running firmware version 1012. Leftover demo functionality allows for arbitrarily rebooting the device without authentication. An attacker can send a UDP packet to trigger this vulnerability. Insteon Hub There are authentication vulnerabilities in the firmware.Service operation interruption (DoS) There is a possibility of being put into a state. InsteonHub is an Insteon central controller from Insteon, USA. This product can remotely control light bulbs, wall switches, air conditioners, etc. in the home. Insteon Hub is an Insteon central controller product of Insteon Company in the United States",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "TALOS",
        "id": "TALOS-2017-0485",
        "trust": 3.1
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874",
        "trust": 0.6
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-97365",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "id": "VAR-201808-0157",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      }
    ],
    "trust": 1.3825397
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": "Gateway / Hub: Open Ecosystem",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:56:56.993000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Insteon Hub",
        "trust": 0.8,
        "url": "https://www.insteon.com/insteon-hub"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.talosintelligence.com/vulnerability_reports/talos-2017-0485"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16348"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16348"
      },
      {
        "trust": 0.6,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2017-0485"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "date": "2018-08-23T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "date": "2018-11-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "date": "2018-08-23T14:29:00.213000",
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "date": "2018-08-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-16874"
      },
      {
        "date": "2023-01-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107261"
      },
      {
        "date": "2018-11-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      },
      {
        "date": "2023-01-28T01:50:25.210000",
        "db": "NVD",
        "id": "CVE-2017-16348"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Insteon Hub Firmware authentication vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-014189"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-777"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…