VAR-201808-0888

Vulnerability from variot - Updated: 2023-12-18 13:02

An exploitable firmware update vulnerability exists in Insteon Hub running firmware version 1013. The HTTP server allows for uploading arbitrary MPFS binaries that could be modified to enable access to hidden resources which allow for uploading unsigned firmware images to the device. To trigger this vulnerability, an attacker can upload an MPFS binary via the '/mpfsupload' HTTP form and later on upload the firmware via a POST request to 'firmware.htm'. Insteon Hub The firmware contains a vulnerability related to unlimited uploads of dangerous types of files.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Insteon Hub is an Insteon central controller product of Insteon Company in the United States. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201808-0888",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "hub 2245-222",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "insteon",
        "version": "1013"
      },
      {
        "model": "hub",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "insteon",
        "version": "firmware  1013"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:insteon:hub_2245-222_firmware:1013:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      }
    ]
  },
  "cve": "CVE-2018-3832",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.5,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.8,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 8.5,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2018-3832",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.5,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.8,
            "id": "VHN-133863",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.0,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.3,
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "talos-cna@cisco.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.1,
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.0,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-3832",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-3832",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "talos-cna@cisco.com",
            "id": "CVE-2018-3832",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201808-776",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-133863",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable firmware update vulnerability exists in Insteon Hub running firmware version 1013. The HTTP server allows for uploading arbitrary MPFS binaries that could be modified to enable access to hidden resources which allow for uploading unsigned firmware images to the device. To trigger this vulnerability, an attacker can upload an MPFS binary via the \u0027/mpfsupload\u0027 HTTP form and later on upload the firmware via a POST request to \u0027firmware.htm\u0027. Insteon Hub The firmware contains a vulnerability related to unlimited uploads of dangerous types of files.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Insteon Hub is an Insteon central controller product of Insteon Company in the United States. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "TALOS",
        "id": "TALOS-2018-0511",
        "trust": 2.5
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776",
        "trust": 0.7
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-97358",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-133863",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "id": "VAR-201808-0888",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      }
    ],
    "trust": 0.7825397
  },
  "last_update_date": "2023-12-18T13:02:31.100000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Insteon Hub",
        "trust": 0.8,
        "url": "http://www.insteon.com/insteon-hub"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-434",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://www.talosintelligence.com/vulnerability_reports/talos-2018-0511"
      },
      {
        "trust": 1.6,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/144976"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-3832"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-3832"
      },
      {
        "trust": 0.6,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2018-0511"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-08-23T00:00:00",
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "date": "2018-08-23T14:29:00.370000",
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "date": "2018-08-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-133863"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      },
      {
        "date": "2023-02-03T18:39:00.640000",
        "db": "NVD",
        "id": "CVE-2018-3832"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Insteon Hub Firmware unreliable upload vulnerability type file vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009271"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201808-776"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…