VAR-201808-0917
Vulnerability from variot - Updated: 2023-12-26 23:00An exploitable buffer overflow vulnerability exists in the /cameras/XXXX/clips handler of video-core's HTTP server of Samsung SmartThings Hub STH-ETH-250 Firmware version 0.20.17. The strncpy call overflows the destination buffer, which has a size of 52 bytes. An attacker can send an arbitrarily long 'endTime' value in order to exploit this vulnerability. An attacker can send an HTTP request to trigger this vulnerability. Samsung SmartThings Hub STH-ETH-250 The firmware contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SamsungSmartThingsHub is a smart home management device from South Korea's Samsung. video-coreHTTPserver is one of the HTTP servers
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0917",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sth-eth-250",
"scope": "eq",
"trust": 1.6,
"vendor": "samsung",
"version": "0.20.17"
},
{
"model": "smartthings hub sth-eth-250",
"scope": "eq",
"trust": 1.4,
"vendor": "samsung",
"version": "0.20.17"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:samsung:sth-eth-250_firmware:0.20.17:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:samsung:sth-eth-250:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-3895"
}
]
},
"cve": "CVE-2018-3895",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-3895",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-17069",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-133926",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "talos-cna@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.1,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-3895",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-3895",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2018-3895",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2018-17069",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-868",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-133926",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-3895",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An exploitable buffer overflow vulnerability exists in the /cameras/XXXX/clips handler of video-core\u0027s HTTP server of Samsung SmartThings Hub STH-ETH-250 Firmware version 0.20.17. The strncpy call overflows the destination buffer, which has a size of 52 bytes. An attacker can send an arbitrarily long \u0027endTime\u0027 value in order to exploit this vulnerability. An attacker can send an HTTP request to trigger this vulnerability. Samsung SmartThings Hub STH-ETH-250 The firmware contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SamsungSmartThingsHub is a smart home management device from South Korea\u0027s Samsung. video-coreHTTPserver is one of the HTTP servers",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-3895",
"trust": 3.2
},
{
"db": "TALOS",
"id": "TALOS-2018-0570",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2018-17069",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-133926",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-3895",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"id": "VAR-201808-0917",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
}
],
"trust": 0.06999999999999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
}
]
},
"last_update_date": "2023-12-26T23:00:09.030000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SmarThings Hub",
"trust": 0.8,
"url": "https://www.smartthings.com/products/smartthings-hub"
},
{
"title": "Patch for SamsungSmartThingsHub Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/139003"
},
{
"title": "Samsung SmartThings Hub STH-ETH-250 video-core HTTP Server Buffer Error Vulnerability Fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=84318"
},
{
"title": "Awesome CVE PoC",
"trust": 0.1,
"url": "https://github.com/lnick2023/nicenice "
},
{
"title": "Awesome CVE PoC",
"trust": 0.1,
"url": "https://github.com/qazbnm456/awesome-cve-poc "
},
{
"title": "Awesome CVE PoC",
"trust": 0.1,
"url": "https://github.com/xbl3/awesome-cve-poc_qazbnm456 "
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-3895"
},
{
"trust": 1.8,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2018-0570"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-3895"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/120.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/lnick2023/nicenice"
},
{
"trust": 0.1,
"url": "https://github.com/qazbnm456/awesome-cve-poc"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"db": "VULHUB",
"id": "VHN-133926"
},
{
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"date": "2018-08-28T00:00:00",
"db": "VULHUB",
"id": "VHN-133926"
},
{
"date": "2018-08-28T00:00:00",
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"date": "2018-12-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"date": "2018-08-28T19:29:19.113000",
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"date": "2018-08-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-31T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-17069"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULHUB",
"id": "VHN-133926"
},
{
"date": "2022-12-02T00:00:00",
"db": "VULMON",
"id": "CVE-2018-3895"
},
{
"date": "2018-12-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-010253"
},
{
"date": "2022-12-02T22:59:23.323000",
"db": "NVD",
"id": "CVE-2018-3895"
},
{
"date": "2022-12-05T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Samsung SmartThings Hub STH-ETH-250 Firmware buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-010253"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-868"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.