VAR-201809-0043
Vulnerability from variot - Updated: 2023-12-18 12:36An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability. Insteon Hub Contains an information disclosure vulnerability.Information may be obtained. INSTEON Hub is an INSTEON central controller product of the American INSTEON company. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201809-0043",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hub 2245-222",
"scope": "eq",
"trust": 1.0,
"vendor": "insteon",
"version": "1012"
},
{
"model": "hub",
"scope": "eq",
"trust": 0.8,
"vendor": "insteon",
"version": "1012"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:insteon:hub_2245-222_firmware:1012:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:insteon:hub_2245-222:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14443"
}
]
},
"cve": "CVE-2017-14443",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2017-14443",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-105166",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "talos-cna@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.1,
"impactScore": 5.8,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-14443",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-14443",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "talos-cna@cisco.com",
"id": "CVE-2017-14443",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-201709-625",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-105166",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105166"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An exploitable information leak vulnerability exists in Insteon Hub running firmware version 1012. The HTTP server implementation incorrectly checks the number of GET parameters supplied, leading to an arbitrarily controlled information leak on the whole device memory. An attacker can send an authenticated HTTP request to trigger this vulnerability. Insteon Hub Contains an information disclosure vulnerability.Information may be obtained. INSTEON Hub is an INSTEON central controller product of the American INSTEON company. This product can remotely control light bulbs, wall switches, air conditioners, etc. in your home",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "VULHUB",
"id": "VHN-105166"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "TALOS",
"id": "TALOS-2017-0492",
"trust": 2.5
},
{
"db": "NVD",
"id": "CVE-2017-14443",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201709-625",
"trust": 0.7
},
{
"db": "SEEBUG",
"id": "SSVID-97363",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-105166",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105166"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"id": "VAR-201809-0043",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-105166"
}
],
"trust": 0.7825397
},
"last_update_date": "2023-12-18T12:36:35.062000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Insteon Hub",
"trust": 0.8,
"url": "https://www.insteon.com/insteon-hub"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105166"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://www.talosintelligence.com/vulnerability_reports/talos-2017-0492"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-14443"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-14443"
},
{
"trust": 0.6,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2017-0492"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-105166"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-105166"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-17T00:00:00",
"db": "VULHUB",
"id": "VHN-105166"
},
{
"date": "2019-03-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"date": "2018-09-17T17:29:00.267000",
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"date": "2017-09-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-12-14T00:00:00",
"db": "VULHUB",
"id": "VHN-105166"
},
{
"date": "2019-03-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014377"
},
{
"date": "2022-12-14T16:13:10.983000",
"db": "NVD",
"id": "CVE-2017-14443"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Insteon Hub Vulnerable to information disclosure",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014377"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201709-625"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…