VAR-201810-0128
Vulnerability from variot - Updated: 2024-02-13 22:30Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp. Advantech WebAccess Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Advantech WebAccess is a suite of browser-based HMI/SCADA software from Advantech. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201810-0128",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "webaccess",
"scope": "lte",
"trust": 1.8,
"vendor": "advantech",
"version": "8.3.2"
},
{
"model": "webaccess",
"scope": "lte",
"trust": 0.6,
"vendor": "advantech",
"version": "\u003c=8.3.2"
},
{
"model": "webaccess",
"scope": "eq",
"trust": 0.6,
"vendor": "advantech",
"version": "8.3.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "webaccess",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:advantech:webaccess:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.3.2",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"cve": "CVE-2018-15704",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-15704",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-21797",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-125990",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-15704",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-15704",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-21797",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201810-1121",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-125990",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-15704",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Advantech WebAccess 8.3.2 and below is vulnerable to a stack buffer overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability by sending a crafted HTTP request to broadweb/system/opcImg.asp. Advantech WebAccess Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Advantech WebAccess is a suite of browser-based HMI/SCADA software from Advantech. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "VULMON",
"id": "CVE-2018-15704"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-15704",
"trust": 3.4
},
{
"db": "TENABLE",
"id": "TRA-2018-33",
"trust": 2.6
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-21797",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103",
"trust": 0.8
},
{
"db": "IVD",
"id": "E2FE7AB1-39AB-11E9-8710-000C29342CB1",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-125990",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-15704",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"id": "VAR-201810-0128",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "VULHUB",
"id": "VHN-125990"
}
],
"trust": 1.33267184
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
}
]
},
"last_update_date": "2024-02-13T22:30:41.829000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Advantech WebAccess",
"trust": 0.8,
"url": "http://www.advantech.com/industrial-automation/webaccess/webaccessscada"
},
{
"title": "Check Point Security Alerts: Advantech WebAccess Buffer Overflow (CVE-2018-15704)",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=check_point_security_alerts\u0026qid=ead700aab13b40fd4fe05b6f6af7e21e"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.tenable.com/security/research/tra-2018-33"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-15704"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-15704"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://advisories.checkpoint.com/defense/advisories/public/2024/cpai-2018-2677.html"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"db": "VULHUB",
"id": "VHN-125990"
},
{
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-26T00:00:00",
"db": "IVD",
"id": "e2fe7ab1-39ab-11e9-8710-000c29342cb1"
},
{
"date": "2018-10-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"date": "2018-10-22T00:00:00",
"db": "VULHUB",
"id": "VHN-125990"
},
{
"date": "2018-10-22T00:00:00",
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"date": "2019-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"date": "2018-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"date": "2018-10-22T19:29:00.453000",
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-21797"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-125990"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-15704"
},
{
"date": "2019-01-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1121"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2018-15704"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Advantech WebAccess Buffer error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-011103"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1121"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…