WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code. WebAccess Contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability allows local attackers to escalate privileges on vulnerable installations of Advantech WebAccess Node. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the access controls that are set and modified during the installation of the product. Advantech (Advantech) WebAccess software is the core of Advantech's IoT application platform solution, providing users with a user interface based on HTML5 technology to achieve cross-platform and cross-browser data access experience. Advantech WebAccess is prone to the following security vulnerabilities: 1. A stack-based buffer overflow vulnerability 2. This may aid in further attacks. Advantech WebAccess is a browser-based HMI/SCADA software developed by Advantech. The software supports dynamic graphic display and real-time data control, and provides functions of remote control and management of automation equipment
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0492", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "webaccess", "scope": "lte", "trust": 1.8, "vendor": "advantech", "version": "8.3.2" }, { "model": "webaccess", "scope": null, "trust": 1.4, "vendor": "advantech", "version": null }, { "model": "webaccess", "scope": "eq", "trust": 0.9, "vendor": "advantech", "version": "8.3.2" }, { "model": "webaccess", "scope": "lte", "trust": 0.6, "vendor": "advantech", "version": "\u003c=8.3.1" }, { "model": "webaccess", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "8.3.1" }, { "model": "webaccess", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "8.3" }, { "model": "webaccess", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "8.2" }, { "model": "webaccess", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "8.1" }, { "model": "webaccess", "scope": "eq", "trust": 0.3, "vendor": "advantech", "version": "8" }, { "model": "webaccess", "scope": "ne", "trust": 0.3, "vendor": "advantech", "version": "8.3.3" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "webaccess", "version": "*" } ], "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "BID", "id": "105736" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:advantech:webaccess:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "8.3.2", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-17908" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mat Powell of Trend Micro Zero Day Initiative", "sources": [ { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" } ], "trust": 1.4 }, "cve": "CVE-2018-17908", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2018-17908", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2018-21936", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "VHN-128414", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.5, "id": "CVE-2018-17908", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.4, "userInteraction": "NONE", "vectorString": "AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-17908", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-17908", "trust": 1.8, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2018-17908", "trust": 1.4, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2018-21936", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201810-1272", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-128414", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "VULHUB", "id": "VHN-128414" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code. WebAccess Contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability allows local attackers to escalate privileges on vulnerable installations of Advantech WebAccess Node. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the access controls that are set and modified during the installation of the product. Advantech (Advantech) WebAccess software is the core of Advantech\u0027s IoT application platform solution, providing users with a user interface based on HTML5 technology to achieve cross-platform and cross-browser data access experience. Advantech WebAccess is prone to the following security vulnerabilities:\n1. A stack-based buffer overflow vulnerability\n2. This may aid in further attacks. Advantech WebAccess is a browser-based HMI/SCADA software developed by Advantech. The software supports dynamic graphic display and real-time data control, and provides functions of remote control and management of automation equipment", "sources": [ { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "BID", "id": "105736" }, { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-128414" } ], "trust": 3.96 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-17908", "trust": 5.0 }, { "db": "ICS CERT", "id": "ICSA-18-298-02", "trust": 3.4 }, { "db": "BID", "id": "105736", "trust": 2.0 }, { "db": "SECTRACK", "id": "1041957", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201810-1272", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2018-21936", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-011341", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-7167", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-18-1331", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-7154", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-18-1329", "trust": 0.7 }, { "db": "IVD", "id": "E2FEC8CF-39AB-11E9-89CC-000C29342CB1", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-128414", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "VULHUB", "id": "VHN-128414" }, { "db": "BID", "id": "105736" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "id": "VAR-201810-0492", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "VULHUB", "id": "VHN-128414" } ], "trust": 1.33267184 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-21936" } ] }, "last_update_date": "2023-12-18T13:28:43.141000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Advantech has issued an update to correct this vulnerability.", "trust": 1.4, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-298-02" }, { "title": "Advantech WebAccess", "trust": 0.8, "url": "https://www.advantech.com/industrial-automation/webaccess/webaccessscada" }, { "title": "Advantech WebAccess improper access control vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/143395" }, { "title": "Advantech WebAccess Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86344" } ], "sources": [ { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-284", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-128414" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 4.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-298-02" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105736" }, { "trust": 1.7, "url": "http://www.securitytracker.com/id/1041957" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-17908" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-17908" }, { "trust": 0.3, "url": "http://webaccess.advantech.com" } ], "sources": [ { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "VULHUB", "id": "VHN-128414" }, { "db": "BID", "id": "105736" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "ZDI", "id": "ZDI-18-1331" }, { "db": "ZDI", "id": "ZDI-18-1329" }, { "db": "CNVD", "id": "CNVD-2018-21936" }, { "db": "VULHUB", "id": "VHN-128414" }, { "db": "BID", "id": "105736" }, { "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "db": "NVD", "id": "CVE-2018-17908" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-28T00:00:00", "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "date": "2018-10-31T00:00:00", "db": "ZDI", "id": "ZDI-18-1331" }, { "date": "2018-10-31T00:00:00", "db": "ZDI", "id": "ZDI-18-1329" }, { "date": "2018-10-28T00:00:00", "db": "CNVD", "id": "CNVD-2018-21936" }, { "date": "2018-10-29T00:00:00", "db": "VULHUB", "id": "VHN-128414" }, { "date": "2018-10-25T00:00:00", "db": "BID", "id": "105736" }, { "date": "2019-01-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "date": "2018-10-29T18:29:08.277000", "db": "NVD", "id": "CVE-2018-17908" }, { "date": "2018-10-26T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-31T00:00:00", "db": "ZDI", "id": "ZDI-18-1331" }, { "date": "2018-10-31T00:00:00", "db": "ZDI", "id": "ZDI-18-1329" }, { "date": "2018-10-28T00:00:00", "db": "CNVD", "id": "CNVD-2018-21936" }, { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-128414" }, { "date": "2018-10-25T00:00:00", "db": "BID", "id": "105736" }, { "date": "2019-01-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-011341" }, { "date": "2019-10-09T23:37:02.363000", "db": "NVD", "id": "CVE-2018-17908" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-1272" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-1272" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Advantech WebAccess Improper Access Control Vulnerability", "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-21936" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Access control error", "sources": [ { "db": "IVD", "id": "e2fec8cf-39ab-11e9-89cc-000c29342cb1" }, { "db": "CNNVD", "id": "CNNVD-201810-1272" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.