var-201810-0618
Vulnerability from variot
A vulnerability in Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to conduct cross-site request forgery (CSRF) attacks. The vulnerability is due to improper validation of Origin headers on HTTP requests within the management interface. An attacker could exploit this vulnerability by convincing a targeted user to follow a URL to a malicious website. An exploit could allow the attacker to take actions within the software with the privileges of the targeted user or gain access to sensitive information. This issue is being tracked by Cisco bug ID CSCvj33439. The platform can realize the full lifecycle management of virtualized services through the central coordinator and controller
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201810-0618", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "enterprise network virtualization software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "nfvis-8.0" }, { "model": "enterprise network virtualization software", "scope": "eq", "trust": 1.0, "vendor": "cisco", "version": "nfvis-9.0" }, { "model": "enterprise nfv infrastructure software", "scope": null, "trust": 0.8, "vendor": "cisco", "version": null }, { "model": "enterprise nfv infrastructure software", "scope": "eq", "trust": 0.3, "vendor": "cisco", "version": "0" } ], "sources": [ { "db": "BID", "id": "105662" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:enterprise_network_virtualization_software:nfvis-8.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:cisco:enterprise_network_virtualization_software:nfvis-9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-15402" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco", "sources": [ { "db": "BID", "id": "105662" } ], "trust": 0.3 }, "cve": "CVE-2018-15402", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2018-15402", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-125658", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "ykramarz@cisco.com", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "impactScore": 2.5, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-15402", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-15402", "trust": 1.8, "value": "HIGH" }, { "author": "ykramarz@cisco.com", "id": "CVE-2018-15402", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201810-992", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-125658", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-125658" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability in Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to conduct cross-site request forgery (CSRF) attacks. The vulnerability is due to improper validation of Origin headers on HTTP requests within the management interface. An attacker could exploit this vulnerability by convincing a targeted user to follow a URL to a malicious website. An exploit could allow the attacker to take actions within the software with the privileges of the targeted user or gain access to sensitive information. \nThis issue is being tracked by Cisco bug ID CSCvj33439. The platform can realize the full lifecycle management of virtualized services through the central coordinator and controller", "sources": [ { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "BID", "id": "105662" }, { "db": "VULHUB", "id": "VHN-125658" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-15402", "trust": 2.8 }, { "db": "BID", "id": "105662", "trust": 2.0 }, { "db": "JVNDB", "id": "JVNDB-2018-013850", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201810-992", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-125658", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-125658" }, { "db": "BID", "id": "105662" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "id": "VAR-201810-0618", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-125658" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T13:23:56.260000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "cisco-sa-20181017-nfvis-csrf", "trust": 0.8, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20181017-nfvis-csrf" }, { "title": "Cisco Enterprise NFV Infrastructure Software Fixes for cross-site request forgery vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86063" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-125658" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20181017-nfvis-csrf" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/105662" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-15402" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-15402" }, { "trust": 0.3, "url": "http://www.cisco.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-125658" }, { "db": "BID", "id": "105662" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-125658" }, { "db": "BID", "id": "105662" }, { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "NVD", "id": "CVE-2018-15402" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-10-17T00:00:00", "db": "VULHUB", "id": "VHN-125658" }, { "date": "2018-10-17T00:00:00", "db": "BID", "id": "105662" }, { "date": "2019-03-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "date": "2018-10-17T20:29:00.457000", "db": "NVD", "id": "CVE-2018-15402" }, { "date": "2018-10-18T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-10-09T00:00:00", "db": "VULHUB", "id": "VHN-125658" }, { "date": "2018-10-17T00:00:00", "db": "BID", "id": "105662" }, { "date": "2019-03-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "date": "2019-10-09T23:35:32.360000", "db": "NVD", "id": "CVE-2018-15402" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201810-992" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-992" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Cisco Enterprise NFV Infrastructure Software cross-site request forgery vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-013850" }, { "db": "CNNVD", "id": "CNNVD-201810-992" } ], "trust": 1.4 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-201810-992" } ], "trust": 0.6 } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.